Schneider ATV212WD55N4 Variable Speed Drive - 55kW
Overview
The Schneider ATV212WD55N4 Variable Speed Drive represents the pinnacle of advanced motor control technology, designed to optimize performance and efficiency in demanding industrial applications. With a robust 55kW power rating, this drive is engineered for precision and reliability, making it an ideal choice for a diverse range of automation tasks.
Key Features
- Powerful Performance: Delivers up to 55kW of power, ensuring exceptional control over high-torque applications and demanding operational environments.
- Advanced Control Technology: Incorporates sophisticated algorithms and adaptive control features, providing precise speed regulation and enhanced motor efficiency.
- Versatile Compatibility: Suitable for various motor types, including induction motors, ensuring flexibility and compatibility with existing systems.
- Enhanced Energy Efficiency: Designed to minimize energy consumption and operational costs while maximizing system performance and uptime.
- User-Friendly Interface: Equipped with an intuitive display and easy-to-navigate menu, simplifying installation, configuration, and monitoring processes.
- Robust Design: Built to withstand harsh industrial conditions with a durable enclosure that provides reliable protection against dust, moisture, and mechanical impact.
- Flexible Communication: Features multiple communication options, including Modbus and Profibus, to integrate seamlessly into existing network architectures.
- Safety and Compliance: Complies with international safety standards and regulations, ensuring reliable protection for operators and equipment.
Applications
The Schneider ATV212WD55N4 is ideal for applications requiring high power and precision, such as:
- Pumping Systems: Optimizes pump performance and efficiency in water and wastewater treatment facilities.
- HVAC Systems: Enhances the control of fans and compressors in heating, ventilation, and air conditioning systems.
- Conveyor Systems: Provides smooth and reliable speed control for conveyor belts in manufacturing and material handling operations.
- Industrial Machinery: Offers precise control for various industrial processes and machinery, improving overall productivity and operational reliability.
Technical Specifications
- Power Rating: 55kW
- Input Voltage: 380-480V, 3-phase
- Frequency Range: 0-400Hz
- Control Method: Vector Control, V/f Control
- Protection Class: IP20 (standard), IP54 (optional)
- Communication Protocols: Modbus RTU, Profibus DP
- Operating Temperature: -10°C to +50°C
- Cooling Method: Air-Cooled
Benefits
- Increased Efficiency: Reduces energy consumption and operational costs through precise speed control and efficient motor management.
- Enhanced Reliability: Ensures stable and reliable performance in demanding applications with a robust and durable design.
- Ease of Use: Simplifies setup and operation with a user-friendly interface and comprehensive diagnostic tools.
Why Choose Schneider ATV212WD55N4?
The Schneider ATV212WD55N4 Variable Speed Drive stands out for its superior performance, advanced control features, and robust design. It is engineered to meet the highest standards of quality and reliability, making it the ideal solution for complex industrial automation needs.
range of product |
Altivar 212
|
|
---|---|---|
product or component type |
Variable speed drive
|
|
device short name |
ATV212
|
|
product destination |
Asynchronous motors
|
|
product specific application |
Pumps and fans in HVAC
|
|
assembly style |
With heat sink
|
|
network number of phases |
3 phases
|
|
motor power kW |
22 kW
|
|
motor power hp |
30 hp
|
|
[Us] rated supply voltage |
380...480 V - 15...10 %
|
|
supply voltage limits |
323...528 V
|
|
supply frequency |
50...60 Hz - 5...5 %
|
|
network frequency |
47.5...63 Hz
|
|
EMC filter |
Class C1 EMC filter integrated
|
|
line current |
33.1 A 480 V
41.1 A 380 V |
apparent power |
33.2 kVA 380 V
|
|
---|---|---|
prospective line Isc |
22 kA
|
|
continuous output current |
43.5 A 380 V
43.5 A 460 V |
|
maximum transient current |
47.9 A 60 s
|
|
speed drive output frequency |
0.5...200 Hz
|
|
nominal switching frequency |
8 kHz
|
|
switching frequency |
6...16 kHz adjustable
8...16 kHz with derating factor |
|
speed range |
1...10
|
|
speed accuracy |
+/- 10 % of nominal slip 0.2 Tn to Tn
|
|
torque accuracy |
+/- 15 %
|
|
transient overtorque |
120 % of nominal motor torque +/- 10 % 60 s
|
|
asynchronous motor control profile |
Voltage/frequency ratio, 2 points
Voltage/frequency ratio, automatic IR compensation (U/f + automatic Uo) Voltage/frequency ratio - Energy Saving, quadratic U/f Flux vector control without sensor, standard Voltage/frequency ratio, 5 points |
|
regulation loop |
Adjustable PI regulator
|
|
motor slip compensation |
Not available in voltage/frequency ratio motor control
Automatic whatever the load Adjustable |
|
local signalling |
1 LED red DC bus energized
|
|
output voltage |
<= power supply voltage
|
|
isolation |
Electrical between power and control
|
|
type of cable |
IEC cable without mounting kit 1 45 °C copper 90 °C XLPE/EPR
IEC cable without mounting kit 1 45 °C copper 70 °C PVC UL 508 cable with UL Type 1 kit 3 40 °C copper 75 °C PVC |
|
electrical connection |
Terminal 2.5 mm² AWG 14 VIA, VIB, FM, FLA, FLB, FLC, RY, RC, F,
R, RES
Terminal 25 mm² AWG 3 L1/R, L2/S, L3/T Terminal 50 mm² AWG 1/0 U/T1, V/T2, W/T3 |
|
tightening torque |
4.3 N.m 38 lb.in L1/R, L2/S, L3/T
24 N.m 212 lb.in U/T1, V/T2, W/T3 0.6 N.m VIA, VIB, FM, FLA, FLB, FLC, RY, RC, F, R, RES |
|
supply |
Internal supply for reference potentiometer (1 to 10 kOhm) 10.5
V DC +/- 5 % <= 10 A overload and short-circuit protection
Internal supply 24 V DC 21...27 V <= 200 A overload and short-circuit protection |
|
analogue input number |
2
|
|
analogue input type |
Switch-configurable voltage VIA 0...10 V DC 24 V max 30000 Ohm
10 bits
Configurable voltage VIB 0...10 V DC 24 V max 30000 Ohm 10 bits Configurable PTC probe VIB 0...6 probes 1500 Ohm Switch-configurable current VIA 0...20 mA 250 Ohm 10 bits |
|
sampling duration |
2 ms +/- 0.5 ms F discrete
2 ms +/- 0.5 ms R discrete 2 ms +/- 0.5 ms RES discrete 3.5 ms +/- 0.5 ms VIA analog 22 ms +/- 0.5 ms VIB analog |
|
response time |
2 ms +/- 0.5 ms FM analog
7 ms +/- 0.5 ms FLA, FLC discrete 7 ms +/- 0.5 ms FLB, FLC discrete 7 ms +/- 0.5 ms RY, RC discrete |
|
accuracy |
+/- 0.6 % VIA for a temperature variation 60 °C
+/- 0.6 % VIB for a temperature variation 60 °C +/- 1 % FM for a temperature variation 60 °C |
|
linearity error |
+/- 0.15 % of maximum value input VIA
+/- 0.15 % of maximum value input VIB +/- 0.2 % output FM |
|
analogue output number |
1
|
|
analogue output type |
Switch-configurable voltage FM 0...10 V DC 7620 Ohm 10 bits
Switch-configurable current FM 0...20 mA 970 Ohm 10 bits |
|
discrete output number |
2
|
|
discrete output type |
Configurable relay logic FLA, FLC NO 100000 cycles
Configurable relay logic FLB, FLC NC 100000 cycles Configurable relay logic RY, RC NO 100000 cycles |
|
minimum switching current |
3 mA 24 V DC configurable relay logic
|
|
maximum switching current |
5 A 250 V AC resistive cos phi = 1 L/R = 0 ms FL, R
5 A 30 V DC resistive cos phi = 1 L/R = 0 ms FL, R 2 A 250 V AC inductive cos phi = 0.4 L/R = 7 ms FL, R 2 A 30 V DC inductive cos phi = 0.4 L/R = 7 ms FL, R |
|
discrete input type |
Programmable F 24 V DC level 1 PLC 4700 Ohm
Programmable R 24 V DC level 1 PLC 4700 Ohm Programmable RES 24 V DC level 1 PLC 4700 Ohm |
|
discrete input logic |
Positive logic (source) F, R, RES <= 5 V >= 11 V
Negative logic (sink) F, R, RES >= 16 V <= 10 V |
|
acceleration and deceleration ramps |
Linear adjustable separately from 0.01 to 3200 s
Automatic based on the load |
|
braking to standstill |
By DC injection
|
|
protection type |
Motor phase break motor
Break on the control circuit drive Thermal power stage drive Overvoltages on the DC bus drive Against exceeding limit speed drive Against input phase loss drive With PTC probes motor Input phase breaks drive Line supply overvoltage and undervoltage drive Line supply undervoltage drive Overcurrent between output phases and earth drive Overheating protection drive Short-circuit between motor phases drive Thermal protection motor |
|
dielectric strength |
3535 V DC between earth and power terminals
5092 V DC between control and power terminals |
|
insulation resistance |
>= 1 MOhm 500 V DC for 1 minute
|
|
frequency resolution |
0.024/50 Hz analog input
0.1 Hz display unit |
|
communication port protocol |
LonWorks
METASYS N2 APOGEE FLN BACnet Modbus |
|
connector type |
1 open style
1 RJ45 |
|
physical interface |
2-wire RS 485
|
|
transmission frame |
RTU
|
|
transmission rate |
9600 bps or 19200 bps
|
|
data format |
8 bits, 1 stop, odd even or no configurable parity
|
|
type of polarization |
No impedance
|
|
number of addresses |
1...247
|
|
communication service |
Read holding registers (03) 2 words maximum
Read device identification (43) Monitoring inhibitable Write multiple registers (16) 2 words maximum Write single register (06) Time out setting from 0.1 to 100 s |
|
option card |
Communication card LonWorks
|
|
operating position |
Vertical +/- 10 degree
|
|
width |
284 mm
|
|
height |
720 mm
|
|
depth |
315 mm
|
|
product weight |
58.5 kg
|
|
specific application |
HVAC
|
|
IP degree of protection |
IP55
|
electromagnetic compatibility |
Conducted radio-frequency immunity test level 3 IEC 61000-4-6
Voltage dips and interruptions immunity test IEC 61000-4-11 1.2/50 µs - 8/20 µs surge immunity test level 3 IEC 61000-4-5 Electrical fast transient/burst immunity test level 4 IEC 61000-4-4 Electrostatic discharge immunity test level 3 IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 IEC 61000-4-3 |
|
---|---|---|
pollution degree |
3 IEC 61800-5-1
|
|
IP degree of protection |
IP55 EN/IEC 61800-5-1
IP55 EN/IEC 60529 |
|
vibration resistance |
1 gn 13...200 Hz EN/IEC 60068-2-8
1.5 mm 3...13 Hz EN/IEC 60068-2-6 |
|
shock resistance |
15 gn 11 ms IEC 60068-2-27
|
|
environmental characteristic |
Classes 3C1 IEC 60721-3-3
Classes 3S2 IEC 60721-3-3 |
|
noise level |
59.9 dB 86/188/EEC
|
|
operating altitude |
1000...3000 m limited to 2000 m for the Corner Grounded
distribution network with current derating 1 % per 100 m
<= 1000 m without derating |
|
relative humidity |
5...95 % without condensation IEC 60068-2-3
5...95 % without dripping water IEC 60068-2-3 |
|
ambient air temperature for operation |
-10...40 °C without derating
> 40...50 °C with derating factor |
|
ambient air temperature for storage |
-25...70 °C
|
|
standards |
EN 61800-3 environments 2 category C3
EN 61800-5-1 IEC 61800-3 IEC 61800-3 environments 2 category C3 EN 55011 group 1 class B IEC 61800-3 category C1 EN 61800-3 environments 2 category C2 EN 61800-3 environments 1 category C2 EN 61800-3 category C1 EN 61800-3 environments 1 category C1 IEC 61800-3 environments 1 category C1 EN 61800-3 EN 61800-3 environments 1 category C3 IEC 61800-3 environments 2 category C2 EN 61800-3 environments 2 category C1 IEC 61800-3 environments 2 category C1 IEC 61800-3 environments 1 category C3 IEC 61800-3 environments 1 category C2 IEC 61800-5-1 |
|
product certifications |
UL
CSA NOM 117 C-Tick |
|
marking |
CE
|