Schneider ATV212WU75N4C Variable Speed Drive - 7.5kW
Optimize Your Operations with Precision and Efficiency
The Schneider ATV212WU75N4C Variable Speed Drive is engineered to deliver superior control and efficiency for your industrial applications. With a robust 7.5kW power capacity, this advanced drive is designed to enhance performance while ensuring energy savings and operational flexibility.
Key Features:
- High-Performance Control: The ATV212WU75N4C offers precise speed and torque control, making it ideal for demanding applications requiring exact motor management.
- Versatile Compatibility: Compatible with a wide range of asynchronous motors, this drive provides seamless integration into various systems and environments.
- Advanced Communication Protocols: Equipped with integrated Modbus and CANopen communication options, the ATV212WU75N4C ensures efficient data exchange and easy system integration.
- Energy Efficiency: Designed with cutting-edge technology, this drive optimizes energy consumption and reduces operating costs, contributing to a greener, more sustainable operation.
- User-Friendly Interface: Featuring an intuitive display and simple programming options, the ATV212WU75N4C makes setup and operation straightforward, even for complex applications.
- Durability and Reliability: Built with high-quality components and a robust design, this variable speed drive withstands harsh operating conditions and delivers long-term reliability.
Technical Specifications:
- Power Rating: 7.5kW
- Voltage Range: 380-480V AC
- Frequency Range: 0-600Hz
- Protection Rating: IP20
- Temperature Range: 0-50°C
- Communication Protocols: Modbus RTU, CANopen
Applications:
The Schneider ATV212WU75N4C is perfect for a variety of applications, including:
- Pumps: For precise flow control and energy efficiency.
- Fans: To adjust air flow rates and save energy.
- Conveyors: For smooth and reliable material handling.
- Compressors: To manage pressure and optimize performance.
Why Choose Schneider ATV212WU75N4C?
Investing in the Schneider ATV212WU75N4C Variable Speed Drive means investing in quality, performance, and efficiency. Its advanced features and robust design ensure reliable operation and significant cost savings over time. Ideal for both new installations and retrofits, this drive provides exceptional value and flexibility for diverse industrial needs.
Enhance Your Industrial Performance Today
Upgrade to the Schneider ATV212WU75N4C Variable Speed Drive and experience the benefits of advanced motor control, energy savings, and operational reliability. Contact us to learn more about how this drive can transform your operations.
range of product |
Altivar 212
|
|
---|---|---|
product or component type |
Variable speed drive
|
|
device short name |
ATV212
|
|
product destination |
Asynchronous motors
|
|
product specific application |
Pumps and fans in HVAC
|
|
assembly style |
With heat sink
|
|
network number of phases |
3 phases
|
|
motor power kW |
22 kW
|
|
motor power hp |
30 hp
|
|
[Us] rated supply voltage |
380...480 V - 15...10 %
|
|
supply voltage limits |
323...528 V
|
|
supply frequency |
50...60 Hz - 5...5 %
|
|
network frequency |
47.5...63 Hz
|
|
EMC filter |
Class C1 EMC filter integrated
|
|
line current |
33.1 A 480 V
41.1 A 380 V |
apparent power |
33.2 kVA 380 V
|
|
---|---|---|
prospective line Isc |
22 kA
|
|
continuous output current |
43.5 A 380 V
43.5 A 460 V |
|
maximum transient current |
47.9 A 60 s
|
|
speed drive output frequency |
0.5...200 Hz
|
|
nominal switching frequency |
8 kHz
|
|
switching frequency |
6...16 kHz adjustable
8...16 kHz with derating factor |
|
speed range |
1...10
|
|
speed accuracy |
+/- 10 % of nominal slip 0.2 Tn to Tn
|
|
torque accuracy |
+/- 15 %
|
|
transient overtorque |
120 % of nominal motor torque +/- 10 % 60 s
|
|
asynchronous motor control profile |
Voltage/frequency ratio, 2 points
Voltage/frequency ratio, automatic IR compensation (U/f + automatic Uo) Voltage/frequency ratio - Energy Saving, quadratic U/f Flux vector control without sensor, standard Voltage/frequency ratio, 5 points |
|
regulation loop |
Adjustable PI regulator
|
|
motor slip compensation |
Not available in voltage/frequency ratio motor control
Automatic whatever the load Adjustable |
|
local signalling |
1 LED red DC bus energized
|
|
output voltage |
<= power supply voltage
|
|
isolation |
Electrical between power and control
|
|
type of cable |
IEC cable without mounting kit 1 45 °C copper 90 °C XLPE/EPR
IEC cable without mounting kit 1 45 °C copper 70 °C PVC UL 508 cable with UL Type 1 kit 3 40 °C copper 75 °C PVC |
|
electrical connection |
Terminal 2.5 mm² AWG 14 VIA, VIB, FM, FLA, FLB, FLC, RY, RC, F,
R, RES
Terminal 25 mm² AWG 3 L1/R, L2/S, L3/T Terminal 50 mm² AWG 1/0 U/T1, V/T2, W/T3 |
|
tightening torque |
4.3 N.m 38 lb.in L1/R, L2/S, L3/T
24 N.m 212 lb.in U/T1, V/T2, W/T3 0.6 N.m VIA, VIB, FM, FLA, FLB, FLC, RY, RC, F, R, RES |
|
supply |
Internal supply for reference potentiometer (1 to 10 kOhm) 10.5
V DC +/- 5 % <= 10 A overload and short-circuit protection
Internal supply 24 V DC 21...27 V <= 200 A overload and short-circuit protection |
|
analogue input number |
2
|
|
analogue input type |
Switch-configurable voltage VIA 0...10 V DC 24 V max 30000 Ohm
10 bits
Configurable voltage VIB 0...10 V DC 24 V max 30000 Ohm 10 bits Configurable PTC probe VIB 0...6 probes 1500 Ohm Switch-configurable current VIA 0...20 mA 250 Ohm 10 bits |
|
sampling duration |
2 ms +/- 0.5 ms F discrete
2 ms +/- 0.5 ms R discrete 2 ms +/- 0.5 ms RES discrete 3.5 ms +/- 0.5 ms VIA analog 22 ms +/- 0.5 ms VIB analog |
|
response time |
2 ms +/- 0.5 ms FM analog
7 ms +/- 0.5 ms FLA, FLC discrete 7 ms +/- 0.5 ms FLB, FLC discrete 7 ms +/- 0.5 ms RY, RC discrete |
|
accuracy |
+/- 0.6 % VIA for a temperature variation 60 °C
+/- 0.6 % VIB for a temperature variation 60 °C +/- 1 % FM for a temperature variation 60 °C |
|
linearity error |
+/- 0.15 % of maximum value input VIA
+/- 0.15 % of maximum value input VIB +/- 0.2 % output FM |
|
analogue output number |
1
|
|
analogue output type |
Switch-configurable voltage FM 0...10 V DC 7620 Ohm 10 bits
Switch-configurable current FM 0...20 mA 970 Ohm 10 bits |
|
discrete output number |
2
|
|
discrete output type |
Configurable relay logic FLA, FLC NO 100000 cycles
Configurable relay logic FLB, FLC NC 100000 cycles Configurable relay logic RY, RC NO 100000 cycles |
|
minimum switching current |
3 mA 24 V DC configurable relay logic
|
|
maximum switching current |
5 A 250 V AC resistive cos phi = 1 L/R = 0 ms FL, R
5 A 30 V DC resistive cos phi = 1 L/R = 0 ms FL, R 2 A 250 V AC inductive cos phi = 0.4 L/R = 7 ms FL, R 2 A 30 V DC inductive cos phi = 0.4 L/R = 7 ms FL, R |
|
discrete input type |
Programmable F 24 V DC level 1 PLC 4700 Ohm
Programmable R 24 V DC level 1 PLC 4700 Ohm Programmable RES 24 V DC level 1 PLC 4700 Ohm |
|
discrete input logic |
Positive logic (source) F, R, RES <= 5 V >= 11 V
Negative logic (sink) F, R, RES >= 16 V <= 10 V |
|
acceleration and deceleration ramps |
Linear adjustable separately from 0.01 to 3200 s
Automatic based on the load |
|
braking to standstill |
By DC injection
|
|
protection type |
Motor phase break motor
Break on the control circuit drive Thermal power stage drive Overvoltages on the DC bus drive Against exceeding limit speed drive Against input phase loss drive With PTC probes motor Input phase breaks drive Line supply overvoltage and undervoltage drive Line supply undervoltage drive Overcurrent between output phases and earth drive Overheating protection drive Short-circuit between motor phases drive Thermal protection motor |
|
dielectric strength |
3535 V DC between earth and power terminals
5092 V DC between control and power terminals |
|
insulation resistance |
>= 1 MOhm 500 V DC for 1 minute
|
|
frequency resolution |
0.024/50 Hz analog input
0.1 Hz display unit |
|
communication port protocol |
LonWorks
METASYS N2 APOGEE FLN BACnet Modbus |
|
connector type |
1 open style
1 RJ45 |
|
physical interface |
2-wire RS 485
|
|
transmission frame |
RTU
|
|
transmission rate |
9600 bps or 19200 bps
|
|
data format |
8 bits, 1 stop, odd even or no configurable parity
|
|
type of polarization |
No impedance
|
|
number of addresses |
1...247
|
|
communication service |
Read holding registers (03) 2 words maximum
Read device identification (43) Monitoring inhibitable Write multiple registers (16) 2 words maximum Write single register (06) Time out setting from 0.1 to 100 s |
|
option card |
Communication card LonWorks
|
|
operating position |
Vertical +/- 10 degree
|
|
width |
284 mm
|
|
height |
720 mm
|
|
depth |
315 mm
|
|
product weight |
58.5 kg
|
|
specific application |
HVAC
|
|
IP degree of protection |
IP55
|
electromagnetic compatibility |
Conducted radio-frequency immunity test level 3 IEC 61000-4-6
Voltage dips and interruptions immunity test IEC 61000-4-11 1.2/50 µs - 8/20 µs surge immunity test level 3 IEC 61000-4-5 Electrical fast transient/burst immunity test level 4 IEC 61000-4-4 Electrostatic discharge immunity test level 3 IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 IEC 61000-4-3 |
|
---|---|---|
pollution degree |
3 IEC 61800-5-1
|
|
IP degree of protection |
IP55 EN/IEC 61800-5-1
IP55 EN/IEC 60529 |
|
vibration resistance |
1 gn 13...200 Hz EN/IEC 60068-2-8
1.5 mm 3...13 Hz EN/IEC 60068-2-6 |
|
shock resistance |
15 gn 11 ms IEC 60068-2-27
|
|
environmental characteristic |
Classes 3C1 IEC 60721-3-3
Classes 3S2 IEC 60721-3-3 |
|
noise level |
59.9 dB 86/188/EEC
|
|
operating altitude |
1000...3000 m limited to 2000 m for the Corner Grounded
distribution network with current derating 1 % per 100 m
<= 1000 m without derating |
|
relative humidity |
5...95 % without condensation IEC 60068-2-3
5...95 % without dripping water IEC 60068-2-3 |
|
ambient air temperature for operation |
-10...40 °C without derating
> 40...50 °C with derating factor |
|
ambient air temperature for storage |
-25...70 °C
|
|
standards |
EN 61800-3 environments 2 category C3
EN 61800-5-1 IEC 61800-3 IEC 61800-3 environments 2 category C3 EN 55011 group 1 class B IEC 61800-3 category C1 EN 61800-3 environments 2 category C2 EN 61800-3 environments 1 category C2 EN 61800-3 category C1 EN 61800-3 environments 1 category C1 IEC 61800-3 environments 1 category C1 EN 61800-3 EN 61800-3 environments 1 category C3 IEC 61800-3 environments 2 category C2 EN 61800-3 environments 2 category C1 IEC 61800-3 environments 2 category C1 IEC 61800-3 environments 1 category C3 IEC 61800-3 environments 1 category C2 IEC 61800-5-1 |
|
product certifications |
UL
CSA NOM 117 C-Tick |
|
marking |
CE
|