range of product |
Altivar Process ATV900
|
|
---|---|---|
product or component type |
Variable speed drive
|
|
device application |
Industrial application
|
|
device short name |
ATV930
|
|
variant |
Standard version
With braking chopper |
|
product destination |
Asynchronous motors
Synchronous motors |
|
mounting mode |
Wall mount
|
|
EMC filter |
Integrated conforming to EN/IEC 61800-3 category C3 with <= 50 m
motor cable maxi
|
|
IP degree of protection |
IP20 conforming to IEC 61800-5-1
|
|
type of cooling |
Forced convection
|
|
supply frequency |
50...60 Hz (+/- 5 %)
|
|
network number of phases |
3 phases
|
|
[Us] rated supply voltage |
380...480 V (- 15...10 %)
|
|
motor power kW |
90 kW (normal duty)
|
|
motor power hp |
125 hp (normal duty)
|
|
line current |
156.2 A at 380 V (normal duty)
|
|
prospective line Isc |
50 kA
|
|
apparent power |
112.9 kVA at 480 V (normal duty)
|
|
continuous output current |
173 A at 2.5 kHz (normal duty)
|
|
maximum transient current |
207.6 A during 60 s (normal duty)
|
|
asynchronous motor control profile |
Constant torque standard
Variable torque standard Optimized torque mode |
|
synchronous motor control profile |
Permanent magnet motor
Synchronous reluctance motor |
|
speed drive output frequency |
0.1...599 Hz
|
|
nominal switching frequency |
2.5 kHz
|
|
switching frequency |
1...8 kHz adjustable
|
|
safety function |
STO (safe torque off) SIL 3
|
|
number of preset speeds |
16 preset speeds
|
|
communication port protocol |
Modbus serial
Ethernet/IP Modbus TCP |
|
option module |
Slot A : communication module for Profibus DP V1
|
output voltage |
<= power supply voltage
|
|
---|---|---|
motor slip compensation |
Adjustable
Can be suppressed Not available in permanent magnet motor law Automatic whatever the load |
|
acceleration and deceleration ramps |
Linear adjustable separately from 0.01...9999 s
|
|
braking to standstill |
By DC injection
|
|
protection type |
Motor : thermal protection
|
|
frequency resolution |
Display unit : 0.1 Hz
|
|
electrical connection |
Control, screw terminal : 0.5...1.5 mm² (AWG 20...AWG 16)
|
|
connector type |
2 RJ45 (on the control block) for Ethernet IP/Modbus TCP
|
|
physical interface |
2-wire RS 485 for Modbus serial
|
|
transmission frame |
RTU for Modbus serial
|
|
transmission rate |
10/100 Mbit/s for Ethernet IP/Modbus TCP
|
|
exchange mode |
Half duplex, full duplex, autonegotiation for Ethernet IP/Modbus
TCP
|
|
data format |
8 bits, configurable odd, even or no parity for Modbus serial
|
|
type of polarization |
No impedance for Modbus serial
|
|
method of access |
Slave for Modbus TCP
|
|
supply |
External supply for digital inputs : 24 V DC (19...30 V) current
<= 1.25 mA (overload and short-circuit protection)
|
|
local signalling |
3 mono/dual colour LED for local diagnostic
|
|
width |
265 mm
|
|
height |
748 mm
|
|
depth |
307 mm
|
|
analogue input number |
3
|
|
analogue input type |
Software-configurable voltage AI1, AI2, AI3 : 0...10 V DC
impedance 30 kOhm, resolution 12 bits
|
|
discrete input number |
10
|
|
discrete input type |
Programmable DI1...DI8 : 24 V DC (<= 30 V) impedance 3.5 kOhm
|
|
input compatibility |
Discrete input DI1...DI8 : level 1 PLC conforming to EN/IEC
61131-2
|
|
analogue output number |
2
|
|
discrete output number |
2
|
|
discrete output type |
Logic output DQ+ : 0...1 kHz (<= 30 V) DC, 100 mA
|
|
sampling duration |
Discrete input DI1...DI8 : 2 ms (+/- 0.5 ms)
|
|
accuracy |
Analog input AI1, AI2, AI3 : +/- 0.6 % for a temperature
variation 60 °C
Analog output AQ1, AQ2 : +/- 1 % for a temperature variation 60 °C |
|
linearity error |
Analog input AI1, AI2, AI3 : +/- 0.15 % of maximum value
|
|
maximum switching current |
Relay output R1 on resistive load (cos phi = 1) : 3 A at 250 V
AC
|
|
relay output number |
3
|
|
relay output type |
Configurable relay logic R1 : fault relay NO/NC electrical
durability 100000 cycles
|
|
refresh time |
Relay output R1, R2, R3 : 5 ms (+/- 0.5 ms)
|
|
minimum switching current |
Relay output R1, R2, R3 : 5 mA at 24 V DC
|
|
isolation |
Between power and control terminals
|
|
specific application |
Process
|
|
IP degree of protection |
IP21
|
|
motor starter type |
Variable speed drive
|
insulation resistance |
> 1 mOhm at 500 V DC for 1 minute to earth
|
|
---|---|---|
noise level |
68.3 dB conforming to 86/188/EEC
|
|
power dissipation in W |
196 W (natural convection) at 380 V switching frequency 2.5 kHz
|
|
vibration resistance |
1.5 mm peak to peak (f = 2...13 Hz) conforming to IEC 60068-2-6
|
|
shock resistance |
15 gn during 11 ms conforming to IEC 60068-2-27
|
|
volume of cooling air |
295 m3/h
|
|
operating position |
Vertical +/- 10 degree
|
|
THDI |
<= 48 % from 80...100 % of load conforming to IEC 61000-3-12
|
|
electromagnetic compatibility |
Electrostatic discharge immunity test level 3 conforming to IEC
61000-4-2
|
|
pollution degree |
2 EN/IEC 61800-5-1
|
|
environmental characteristic |
Chemical pollution resistance class 3C3 conforming to EN/IEC
60721-3-3
|
|
relative humidity |
5...95 % without condensation conforming to IEC 60068-2-3
|
|
ambient air temperature for operation |
50...60 °C with derating factor
|
|
ambient air temperature for storage |
-40...70 °C
|
|
operating altitude |
1000...4800 m with current derating 1 % per 100 m
|
|
standards |
UL 508C
|
|
product certifications |
TÜV
REACH CSA UL |
|
marking |
CE
|