Schneider ATV960C25T4X1 High Performance Drive System
Model: ATV960C25T4X1
Power Rating: 280/220 kW
Voltage: 480 V
Protection Rating: IP23
Overview:
The Schneider ATV960C25T4X1 is a state-of-the-art high-performance drive system designed for demanding industrial applications. Engineered to deliver exceptional efficiency and reliability, this drive system offers superior control over motor performance, ensuring optimal operation in a variety of environments.
Key Features:
Advanced Performance: With a robust power rating of 280/220 kW, the ATV960C25T4X1 is capable of handling high-torque applications and demanding load conditions, ensuring consistent and reliable performance.
Voltage Compatibility: Operating at 480 V, this drive system is suitable for standard industrial power supplies, providing seamless integration into existing systems and minimizing the need for additional modifications.
Protection Rating IP23: Designed with an IP23 protection rating, the ATV960C25T4X1 is engineered to withstand exposure to limited amounts of dust and water. This makes it ideal for use in environments where light exposure to these elements is expected.
Enhanced Efficiency: The ATV960 series incorporates advanced control algorithms and energy-saving technologies, reducing overall energy consumption and operational costs while improving motor performance.
User-Friendly Interface: Featuring an intuitive control panel and advanced diagnostic capabilities, the ATV960C25T4X1 allows for easy setup, monitoring, and maintenance. This facilitates streamlined operations and reduces downtime.
Robust Build Quality: Constructed with high-grade materials and designed for durability, this drive system ensures long-term reliability even in challenging industrial conditions.
Versatile Applications: Ideal for use in a wide range of applications including pumps, fans, conveyors, and other critical machinery, the ATV960C25T4X1 adapts to various operational requirements, enhancing overall system performance.
Technical Specifications:
- Power Rating: 280/220 kW
- Input Voltage: 480 V
- Protection Class: IP23
- Operating Temperature: -10°C to 50°C
- Control Methods: Vector control, V/f control
- Communication Protocols: Modbus, Profibus, Ethernet/IP
Applications:
The Schneider ATV960C25T4X1 High Performance Drive System is ideal for use in sectors such as manufacturing, mining, water treatment, and HVAC systems. Its ability to deliver precise control and high efficiency makes it a valuable asset for optimizing industrial processes and improving operational performance.
Benefits:
- Reduced Energy Consumption: By optimizing motor control, the ATV960C25T4X1 helps to lower energy costs and improve operational efficiency.
- Enhanced Reliability: The rugged construction and advanced features ensure dependable operation and reduce the likelihood of unexpected downtime.
- Improved Process Control: Advanced control capabilities provide precise regulation of motor speed and torque, enhancing overall process accuracy.
Why Choose Schneider ATV960C25T4X1?
Choosing the Schneider ATV960C25T4X1 means investing in a high-quality drive system that combines performance, efficiency, and durability. Schneider Electric’s commitment to innovation and excellence ensures that this drive system will meet the demands of even the most challenging applications.
Discover the Schneider ATV960C25T4X1 High Performance Drive System today and experience unparalleled control and efficiency in your industrial operations.
For more information or to request a quote, contact us or visit our website.
range of product |
Altivar Process ATV900
|
|
---|---|---|
product or component type |
Variable speed drive
|
|
device application |
Industrial application
|
|
device short name |
ATV960
|
|
product destination |
Asynchronous motors
Synchronous motors |
|
assembly style |
In floor-standing enclosure compact version
|
|
provided equipment |
Graphical operating panel in the enclosure door
Frequency inverter Main switch Line choke Terminal block for main supply Terminal block for motor Enclosure for Spacial SF |
|
cable entry |
Bottom
|
|
colour of enclosure |
Light grey RAL 7035
|
|
IP degree of protection |
IP23 conforming to IEC 61800-5-1
|
|
type of cooling |
Forced convection
|
|
[Us] rated supply voltage |
480 V (+/- 10 %)
|
|
supply frequency |
50/60 Hz (+/- 5 %)
|
|
network number of phases |
3 phases
|
|
overvoltage category |
III
|
|
asynchronous motor control profile |
Constant torque standard
Variable torque standard Optimized torque mode |
|
synchronous motor control profile |
Permanent magnet motor
|
|
output voltage |
<= power supply voltage
|
|
permissible temporary current boost |
1.5 x In for 60 s (heavy duty)
1.2 x In for 60 s (normal duty) |
|
nominal switching frequency |
2.5 kHz
|
|
switching frequency |
2...8 kHz adjustable with derating factor
|
|
speed drive output frequency |
0.1...500 Hz
|
|
motor power kW |
220 kW (heavy duty)
280 kW (normal duty) |
|
continuous output current |
477 A at 2.5 kHz (normal duty)
370 A at 2.5 kHz (heavy duty) |
|
line current |
400 A at 480 V (normal duty)
323 A at 480 V (heavy duty) |
|
apparent power |
333 kVA at 480 V (normal duty)
268 kVA at 480 V (heavy duty) |
|
THDI |
<= 48 % full load conforming to IEC 61000-3-12
|
|
short-circuit protection |
Upstream : 500 A gG fuse (normal duty)
Upstream : 400 A gG fuse (heavy duty) Internal : 315 A 2 aR fuse |
|
power dissipation in W |
5750 W total (normal duty)
4340 W total (heavy duty) 730 W control part (normal duty) 520 W control part (heavy duty) |
|
volume of cooling air |
140 m3/h for control
1160 m3/h for power |
|
noise level |
70 dB 86/188/EEC - physical agents (noise) directive
|
|
prospective line Isc |
50 kA for 100 ms
|
|
electrical connection |
Control : removable screw terminals 0.5...1.5 mm²
Main supply : M12 bar Motor : M12 bar |
|
motor recommanded cable cross section |
2 x (3 x 150 mm²) (normal duty)
3 x (3 x 95 mm²) (normal duty) 2 x (3 x 120 mm²) (heavy duty) 3 x (3 x 70 mm²) (heavy duty) |
|
width |
600 mm
|
|
height |
2150 mm
|
|
depth |
664 mm
|
|
product weight |
400 kg
|
|
number of preset speeds |
16 preset speeds
|
|
communication port protocol |
Ethernet/IP
Modbus serial Modbus TCP |
|
option module |
Slot A : communication module for Profibus DP V1
Slot A : communication module for Profinet Slot A : communication module for DeviceNet Slot A : communication module for CANopen daisy chain RJ45 Slot A : communication module for CANopen SUB-D 9 Slot A : communication module for CANopen screw terminals Slot A : communication module for EtherCAT Slot A/slot B/slot C : digital and analog I/O extension module Slot A/slot B/slot C : output relay extension module Slot B : 5/12 V digital encoder interface module Slot B : analog encoder interface module Slot B : resolver encoder interface module |
|
safety function |
STO (safe torque off) SIL 3 for <= 100 ms
|
|
EMC filter |
Integrated conforming to EN/IEC 61800-3 category C3 shielded
cable with <= 50 m motor cable maxi
Integrated conforming to EN/IEC 61800-3 category C4 unshielded cable with <= 80 m motor cable maxi |
maximum transient current |
555 A 60 s per 10 min heavy duty
572 A 60 s per 10 min normal duty |
|
---|---|---|
motor slip compensation |
Adjustable
Automatic whatever the load Can be suppressed Not available in permanent magnet motor law |
|
acceleration and deceleration ramps |
Linear adjustable separately from 0.01 to 9000 s
S, U or customized |
|
braking to standstill |
By DC injection
|
|
protection type |
Motor : thermal protection
Motor : safe torque off Motor : motor phase break Drive : thermal protection Drive : safe torque off Drive : overheating Drive : short-circuit protection Drive : motor phase break Drive : line supply overvoltage Drive : line supply undervoltage Drive : line supply phase loss Drive : overspeed Drive : break on the control circuit Drive : overcurrent (between output phases and earth) Drive : overload (output) Drive : overvoltage (DC bus) Drive : short-circuit protection with semi-conductor fuse (main supply) Drive : fan monitoring |
|
frequency resolution |
Display unit : 0.1 Hz
Analog input : 0.012/50 Hz |
|
connector type |
2 RJ45 (on the control block) for Ethernet IP/Modbus TCP
1 RJ45 (on the control block) for Modbus serial |
|
physical interface |
2-wire RS 485 for Modbus serial
|
|
transmission frame |
RTU for Modbus serial
|
|
transmission rate |
10/100 Mbit/s for Ethernet IP/Modbus TCP
4.8, 9.6, 19.2, 38.4 kbit/s for Modbus serial |
|
exchange mode |
Half duplex, full duplex, autonegotiation for Ethernet IP/Modbus
TCP
|
|
data format |
8 bits, configurable odd, even or no parity for Modbus serial
|
|
type of polarization |
No impedance for Modbus serial
|
|
number of addresses |
1...247 for Modbus serial
|
|
method of access |
Slave for Modbus TCP
|
|
supply |
External supply for digital inputs : 24 V DC (19...30 V) current
<= 1.25 mA (overload and short-circuit protection)
Internal supply for reference potentiometer (1 to 10 kOhm) : 10.5 V DC +/- 5 % current <= 10 mA (overload and short-circuit protection) Internal supply for digital inputs and STO : 24 V DC (21...27 V) current <= 200 mA (overload and short-circuit protection) |
|
local signalling |
LCD display unit, located on front door for operation function,
status and configuration
|
|
analogue input type |
Software-configurable voltage AI1, AI2, AI3 : 0...10 V DC
impedance 30 kOhm, resolution 12 bits
Software-configurable current AI1, AI2, AI3 : 0...20 mA impedance 250 Ohm, resolution 12 bits |
|
discrete input number |
10
|
|
discrete input type |
Programmable DI1...DI8 : 24 V DC (<= 30 V) impedance 3.5 kOhm
Programmable as pulse input DI7, DI8 0...30 kHz : 24 V DC (<= 30 V) Safe torque off STOA, STOB : 24 V DC (<= 30 V) impedance > 2.2 kOhm |
|
input compatibility |
Discrete input STOA, STOB : level 1 PLC conforming to EN/IEC
61131-2
Discrete input DI1...DI8 : level 1 PLC conforming to EN/IEC 61131-2 Pulse input DI7, DI8 : level 1 PLC conforming to IEC 65A-68 |
|
discrete input logic |
STOA, STOB, positive logic (source) : < 5 V (state 0) > 11 V
(state 1)
DI1...DI8, positive logic (source) : < 5 V (state 0) > 11 V (state 1) DI1...DI8, negative logic (sink) : > 16 V (state 0) < 10 V (state 1) DI7, DI8, positive logic (source) : < 0.6 V (state 0) > 2.5 V (state 1) |
|
analogue output number |
2
|
|
analogue output type |
Software-configurable voltage AQ1, AQ2 : 0...10 V DC impedance
470 Ohm, resolution 10 bits
Software-configurable current AQ1, AQ2 : 0...20 mA impedance 500 Ohm, resolution 10 bits |
|
discrete output number |
2
|
|
discrete output type |
Logic output DQ+ : 0...1 kHz (<= 30 V) DC, 100 mA
Logic output DQ- : 0...1 kHz (<= 30 V) DC, 100 mA Programmable as pulse output DQ+ : 0...30 kHz (<= 30 V) DC, 100 mA |
|
sampling duration |
Discrete input DI1...DI8 : 2 ms (+/- 0.5 ms)
Pulse input DI7, DI8 : 5 ms (+/- 1 ms) Analog input AI1, AI2, AI3 : 1 ms (+/- 1 ms) Analog output AQ1, AQ2 : 5 ms (+/- 1 ms) |
|
accuracy |
Analog input AI1, AI2, AI3 : +/- 0.6 % for a temperature
variation 60 °C
Analog output AQ1, AQ2 : +/- 1 % for a temperature variation 60 °C |
|
linearity error |
Analog input AI1, AI2, AI3 : +/- 0.15 % of maximum value
Analog output AQ1, AQ2 : +/- 0.2 % |
|
relay output number |
3
|
|
relay output type |
Configurable relay logic R1 : fault relay NO/NC electrical
durability 100000 cycles
Configurable relay logic R2 : sequence relay NO electrical durability 1000000 cycles Configurable relay logic R3 : sequence relay NO electrical durability 1000000 cycles |
|
refresh time |
5 ms +/- 0.5 ms R1, R2, R3 relay output
|
|
minimum switching current |
Relay output R1, R2, R3 : 5 mA at 24 V DC
|
|
maximum switching current |
Relay output R1 on resistive load (cos phi = 1) : 3 mA at 250 V
AC
Relay output R1 on resistive load (cos phi = 1) : 3 mA at 30 V DC Relay output R1 on inductive load (cos phi = 0.4 and L/R = 7 ms) : 2 mA at 250 V AC Relay output R1 on inductive load (cos phi = 0.4 and L/R = 7 ms) : 2 mA at 30 V DC Relay output R2, R3 on resistive load (cos phi = 1) : 5 mA at 250 V AC Relay output R2, R3 on resistive load (cos phi = 1) : 5 mA at 30 V DC Relay output R2, R3 on inductive load (cos phi = 0.4 and L/R = 7 ms) : 2 mA at 250 V AC Relay output R2, R3 on inductive load (cos phi = 0.4 and L/R = 7 ms) : 2 mA at 30 V DC |
|
isolation |
Between power and control terminals
|