Schneider ATV9A0C11R4 Variable Speed Drive - Altivar Process Modular ATV900
Overview: The Schneider ATV9A0C11R4 Variable Speed Drive is an advanced solution designed for high-performance motor control in industrial applications. As part of the Altivar Process Modular ATV900 series, this drive offers superior functionality, efficiency, and reliability, making it ideal for demanding environments where precision and adaptability are crucial.
Key Features:
High Power Rating: Delivers robust performance with a power rating of 110 kW, capable of handling high-power loads and ensuring optimal operation in a wide range of industrial processes.
Voltage Compatibility: Operates seamlessly at 440V, providing versatility and ease of integration into existing electrical systems while maintaining stable performance.
Modular Design: The Altivar Process Modular design allows for flexible configuration and expansion, accommodating various application needs and future upgrades.
Enhanced Control: Equipped with advanced control algorithms that optimize motor performance, improve energy efficiency, and reduce operational costs.
Robust Construction: Engineered for durability and reliability, with a rugged construction that ensures long-term operation in harsh environments and under challenging conditions.
User-Friendly Interface: Features an intuitive interface for easy setup and monitoring, allowing operators to quickly configure and adjust settings to meet specific operational requirements.
Technical Specifications:
- Model: ATV9A0C11R4
- Series: Altivar Process Modular ATV900
- Type: Variable Speed Drive
- Power Rating: 110 kW
- Voltage: 440V
- Drive Configuration: Single Drive
- Protection Rating: Designed to withstand industrial environments
Applications:
The Schneider ATV9A0C11R4 is ideal for a variety of applications, including:
- Pumps: Efficient control of pump systems, enhancing performance and energy efficiency.
- Fans: Precision control for ventilation and cooling systems, ensuring optimal airflow and energy savings.
- Conveyors: Reliable speed regulation for conveyor systems, improving process flow and reducing downtime.
- Compressors: Effective control for compressors, enhancing performance and extending equipment life.
Benefits:
- Increased Efficiency: Reduces energy consumption through advanced control strategies, leading to cost savings and improved overall system efficiency.
- Enhanced Flexibility: Modular design allows for easy adaptation to changing needs and integration with other systems.
- Improved Reliability: Durable construction and advanced features ensure reliable operation in demanding industrial settings.
- Simplified Maintenance: Easy-to-use interface and modular components facilitate straightforward maintenance and troubleshooting.
Why Choose Schneider ATV9A0C11R4?
The Schneider ATV9A0C11R4 Variable Speed Drive stands out for its high performance, flexibility, and reliability. Its advanced features and robust design make it a top choice for industries requiring precise and efficient motor control. Choose Schneider for a drive that meets your high standards and supports your operational goals.
ATV9A0C80Q4 ATV9A0C71Q4 ATV9A0C63Q4 ATV9A0C56Q4 ATV9A0C35R4 ATV9A0C40R4 ATV9A0C45R4 ATV9A0C50R4 ATV9A0C56R4 ATV9A0C63R4 ATV9A0C71R4 ATV9A0C80R4 ATV9A0C11T4 ATV9A0C13T4
ATV9A0C16T4 ATV9A0C20T4 ATV9A0C25T4 ATV9A0C31T4 ATV9A0C35T4 ATV9A0C40T4 ATV9A0C45T4 ATV9A0C50T4 ATV9A0C56T4 ATV9A0C63T4 ATV9A0C71T4 ATV9A0C80T4
range of product |
Altivar Process ATV900
|
|
---|---|---|
product or component type |
Variable speed drive
|
|
product specific application |
Process and utilities
|
|
device short name |
ATV9A0
|
|
variant |
Modular version
|
|
product destination |
Synchronous motors
Asynchronous motors |
|
mounting mode |
Cabinet mount
|
|
kit composition |
Mechanical mounting kits
Power connection Set of fuses 1 power module 160 kW 1 control unit |
|
EMC filter |
Integrated conforming to EN/IEC 61800-3 category C3 with <= 300
m motor cable maxi
|
|
IP degree of protection |
IP00 conforming to IEC 61800-5-1 for IP21 or IP54 cabinet
integration
IP00 conforming to IEC 60529 for IP21 or IP54 cabinet integration |
|
type of cooling |
Forced convection
|
|
supply frequency |
50...60 Hz +/- 5 %
|
|
network number of phases |
3 phases
|
|
[Us] rated supply voltage |
440 V - 15...10 %
|
|
motor power kW |
110 kW at 440 V (normal duty)
90 kW at 440 V (heavy duty) |
|
line current |
183 A at 440 V (normal duty)
155 A at 440 V (heavy duty) |
|
prospective line Isc |
50 kA
|
|
apparent power |
139 kVA at 440 V (normal duty)
118 kVA at 440 V (heavy duty) |
|
continuous output current |
211 A at 2.5 kHz (normal duty)
173 A at 2.5 kHz (heavy duty) |
|
maximum transient current |
259.5 A during 60 s (heavy duty)
253.2 A during 60 s (normal duty) |
|
asynchronous motor control profile |
Optimized torque mode
Constant torque standard Variable torque standard |
|
synchronous motor control profile |
Permanent magnet motor
Synchronous reluctance motor |
|
speed drive output frequency |
0.1...599 Hz
|
|
nominal switching frequency |
2.5 kHz
|
|
switching frequency |
2...8 kHz adjustable
2.5...8 kHz with derating factor |
|
safety function |
STO (safe torque off) SIL 3
|
|
communication port protocol |
Ethernet/IP
Modbus TCP Modbus serial |
|
option module |
Slot A : communication module for Profibus DP V1
Slot A : communication module for Profinet Slot A : communication module for DeviceNet Slot A : communication module for CANopen daisy chain RJ45 Slot A : communication module for CANopen SUB-D 9 Slot A : communication module for CANopen screw terminals Slot A : communication module for EtherCAT Slot A/slot B/slot C : digital and analog I/O extension module Slot A/slot B/slot C : output relay extension module Slot B : analog encoder interface module Slot B : resolver encoder interface module Slot B : digital encoder interface module for 5/12 V |
motor slip compensation |
Not available in permanent magnet motor law
Adjustable Automatic whatever the load Can be suppressed |
|
---|---|---|
acceleration and deceleration ramps |
Linear adjustable separately from 0.01...9999 s
|
|
protection type |
Safe torque off motor
Motor phase break motor Safe torque off drive Overheating drive Short-circuit protection drive Motor phase break drive Overspeed drive Break on the control circuit drive Overvoltages on the DC bus drive Overload of output voltage drive Line supply overvoltage drive Line supply phase loss drive Line supply undervoltage drive Overcurrent between output phases and earth drive Thermal protection motor Thermal protection drive |
|
frequency resolution |
0.012/50 Hz analog input
0.1 Hz display unit |
|
electrical connection |
Removable screw terminals 0.5...1.5 mm² AWG 20...AWG 16 control
Screw terminal line side M10 x 2 bars motor |
|
connector type |
2 RJ45 for Ethernet IP/Modbus TCP on the control block
1 RJ45 for Modbus serial on the control block |
|
physical interface |
2-wire RS 485 for Modbus serial
|
|
transmission frame |
RTU for Modbus serial
|
|
transmission rate |
10/100 Mbit/s for Ethernet IP/Modbus TCP
4.8, 9.6, 19.2, 38.4 kbit/s for Modbus serial |
|
exchange mode |
Half duplex, full duplex, autonegotiation for Ethernet IP/Modbus
TCP
|
|
data format |
8 bits, configurable odd, even or no parity for Modbus serial
|
|
type of polarization |
No impedance for Modbus serial
|
|
number of addresses |
For Modbus serial
|
|
method of access |
Slave for Modbus TCP
|
|
supply |
External supply for digital inputs : 24 V DC 19...30 V <= 1.25
mA overload and short-circuit protection
Internal supply for reference potentiometer (1 to 10 kOhm) : 10.5 V DC +/- 5 % <= 10 mA overload and short-circuit protection Internal supply for digital inputs and STO : 24 V DC 21...27 V <= 200 mA overload and short-circuit protection |
|
local signalling |
LED 3 mono/dual colour local diagnostic
LED 5 dual colour embedded communication status LED 2 dual colour communication module status |
|
analogue input type |
Software-configurable voltage AI1, AI3 0...10 V DC 30 kOhm 12
bits
Software-configurable current AI1, AI3 0...20 mA/4...20 mA 250 Ohm 12 bits Software-configurable voltage AI2 +/- 10 V DC 30 kOhm 12 bits Software-configurable voltage AI2 0...10 V DC 30 kOhm 12 bits |
|
discrete input type |
Safe torque off STOA, STOB 24 V DC <= 30 V > 2.2 kOhm
Programmable DI1...DI8 24 V DC <= 30 V 3.5 kOhm Programmable as pulse input DI7, DI8 0...30 kHz 24 V DC <= 30 V |
|
input compatibility |
Level 1 PLC EN/IEC 61131-2 STOA, STOB discrete input
Level 1 PLC EN/IEC 61131-2 DI1...DI8 discrete input Level 1 PLC IEC 65A-68 DI7, DI8 pulse input |
|
discrete input logic |
Positive logic (source) STOA, STOB < 5 V > 11 V
Positive logic (source) DI1...DI8 < 5 V > 11 V Negative logic (sink) DI1...DI8 > 16 V < 10 V Positive logic (source) DI7, DI8 < 0.6 V > 2.5 V |
|
analogue output type |
Software-configurable voltage AQ1, AQ2 0...10 V DC 470 Ohm 10
bits
Software-configurable current AQ1, AQ2 0...20 mA 500 Ohm 10 bits |
|
discrete output type |
Logic output DQ+ 0...1 kHz <= 30 V DC 100 mA
Programmable as pulse output DQ+ 0...30 kHz <= 30 V DC 20 mA Logic output DQ- 0...1 kHz <= 30 V DC 100 mA |
|
sampling duration |
2 ms +/- 0.5 ms DI1...DI8 discrete input
5 ms +/- 1 ms DI7, DI8 pulse input 1 ms +/- 1 ms AI1, AI2, AI3 analog input 5 ms +/- 1 ms AQ1, AQ2 analog output |
|
accuracy |
+/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog
input
+/- 1 % AQ1, AQ2 for a temperature variation 60 °C analog output |
|
linearity error |
+/- 0.15 % of maximum value analog input AI1, AI2, AI3
+/- 0.2 % analog output AQ1, AQ2 |
|
relay output type |
Configurable relay logic R1 fault relay NO/NC 100000 cycles
Configurable relay logic R2 sequence relay NO 1000000 cycles Configurable relay logic R3 sequence relay NO 1000000 cycles |
|
refresh time |
5 ms +/- 0.5 ms R1, R2, R3 relay output
|
|
minimum switching current |
5 mA 24 V DC R1, R2, R3 relay output
|
|
maximum switching current |
3 A 250 V AC resistive 1 R1 relay output
3 A 30 V DC resistive 1 R1 relay output 2 A 250 V AC inductive 0.4 7 ms R1 relay output 2 A 30 V DC inductive 0.4 7 ms R1 relay output 5 A 250 V AC resistive 1 R2, R3 relay output 5 A 30 V DC resistive 1 R2, R3 relay output 2 A 250 V AC inductive 0.4 7 ms R2, R3 relay output 2 A 30 V DC inductive 0.4 7 ms R2, R3 relay output |
insulation resistance |
> 1 MOhm 440 V DC 1 min earth
|
|
---|---|---|
noise level |
69 dB 86/188/EEC
|
|
power dissipation in W |
2390 W forced convection 2.5 kHz
|
|
THDI |
<= 48 % full load conforming to IEC 61000-3-12
|
|
electromagnetic compatibility |
1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to
IEC 61000-4-5
Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6 |
|
pollution degree |
2 EN/IEC 61800-5-1
|
|
vibration resistance |
0.5 gn 13...200 Hz IEC 60068-2-6
1.5 mm peak to peak 2...13 Hz IEC 44068-2-6 |
|
shock resistance |
7 gn 11 ms IEC 44068-2-27
|
|
relative humidity |
5...95 % without condensation conforming to IEC 44068-2-3
|
|
ambient air temperature for operation |
40...50 °C with derating factor
-10...40 °C without |
|
ambient air temperature for storage |
-40...70 °C
|
|
operating altitude |
1000...4800 m with current derating 1 % per 100 m
<= 1000 m without |
|
environmental characteristic |
Chemical pollution resistance class 3C3 EN/IEC 60721-3-3
Dust pollution resistance class 3S3 EN/IEC 60721-3-3 |
|
standards |
EN/IEC 61800-3
EN/IEC 61800-5-1 IEC 61000-3-12 IEC 60721-3 IEC 61508 IEC 13849-1 |
|
product certifications |
UL
CUL REACH TÜV |
|
marking |
CE
|