Schneider ATV9B0C16Q6 Altivar Process Modular Variable Speed Drive - Low Harmonic/Regen Drive
Product Overview: The Schneider ATV9B0C16Q6 Altivar Process Modular Variable Speed Drive is engineered to meet the demanding requirements of industrial applications with precision and efficiency. Designed as part of the renowned ATV900 series, this low harmonic/regen drive delivers exceptional performance and energy savings for a wide range of processes.
Key Features:
Low Harmonic Distortion: The ATV9B0C16Q6 is optimized to minimize harmonic distortion, ensuring cleaner operation and reduced impact on your facility’s power quality. This feature contributes to longer equipment life and lower maintenance costs.
Regenerative Braking Capability: Equipped with advanced regenerative braking technology, this drive recovers and reuses energy, enhancing overall system efficiency and reducing energy consumption. This regenerative feature is ideal for applications with frequent stopping and starting cycles.
Robust Performance: With a power rating of 16 kW and operating voltage capabilities designed to handle demanding industrial environments, the ATV9B0C16Q6 provides reliable and consistent performance, even under heavy loads.
Modular Design: The Altivar Process Modular design allows for flexible configuration and easy integration into various industrial setups. Its modularity supports easy upgrades and future expansions, making it a versatile choice for evolving needs.
Enhanced Control and Monitoring: The drive includes advanced control features that facilitate precise speed regulation and process monitoring. This results in improved operational efficiency and process optimization.
Durability and Reliability: Built with high-quality components, the ATV9B0C16Q6 ensures robust operation in harsh environments. Its durable design minimizes downtime and maintenance requirements, offering long-term reliability.
User-Friendly Interface: The drive features an intuitive interface for ease of setup and operation. Its user-friendly design reduces training time and operational complexity.
Applications: The Schneider ATV9B0C16Q6 is ideal for a variety of industrial applications, including pumps, fans, compressors, and other processes that require precise speed control and energy efficiency. Its low harmonic and regenerative capabilities make it especially suitable for applications where energy savings and power quality are critical.
Technical Specifications:
- Power Rating: 16 kW
- Voltage: Suitable for various industrial voltage requirements
- Control Method: Advanced speed and torque control
- Features: Low harmonic distortion, regenerative braking, modular design
- Environmental Protection: Designed for robust operation in challenging conditions
SEO Tags:
- Schneider ATV9B0C16Q6
- Altivar Process Modular Variable Speed Drive
- Low Harmonic Drive
- Regenerative Drive
- Schneider ATV900 Series
- Industrial Variable Speed Drive
- Energy Efficient Drive
- Regenerative Braking Drive
Enhance your industrial processes with the Schneider ATV9B0C16Q6 Altivar Process Modular Variable Speed Drive, combining advanced technology, efficiency, and reliability for optimal performance in demanding environments.
range of product |
Altivar Process ATV900
|
|
---|---|---|
product or component type |
Variable speed drive
|
|
device short name |
ATV9B0
|
|
variant |
Modular version
|
|
product destination |
Asynchronous motors
Synchronous motors |
|
mounting mode |
Cabinet mount
|
|
kit composition |
Mechanical mounting kits
Power connection Set of fuses 1 control unit 1 power module 200 kW |
|
EMC filter |
Integrated conforming to EN/IEC 61800-3 category C3 with <= 300
m motor cable maxi
|
|
IP degree of protection |
IP00 conforming to IEC 61800-5-1 for IP21 or IP54 cabinet
integration
IP00 conforming to IEC 60529 for IP21 or IP54 cabinet integration |
|
degree of protection |
UL type 1 UL 61800-5-1 cabinet integration
UL type 12 UL 61800-5-1 cabinet integration |
|
type of cooling |
Forced convection
|
|
supply frequency |
50...60 Hz +/- 5 %
|
|
network number of phases |
3 phases
|
|
[Us] rated supply voltage |
690 V - 10...15 %
|
|
motor power kW |
160 kW at 690 V (normal duty)
132 kW at 690 V (heavy duty) 160 kW at 690 V (normal duty) regenerative mode 132 kW at 690 V (heavy duty) regenerative mode |
|
line current |
148 A at 690 V (normal duty)
122 A at 690 V (heavy duty) 121 A at 690 V (normal duty) regenerative mode 99 A at 690 V (heavy duty) regenerative mode |
|
prospective line Isc |
50 kA
|
|
apparent power |
177 kVA at 690 V (normal duty)
146 kVA at 690 V (heavy duty) 145 kVA at 690 V (normal duty) regenerative mode 119 kVA at 690 V (heavy duty) regenerative mode |
|
continuous output current |
145 A at 2.5 kHz (heavy duty)
175 A at 2.5 kHz (normal duty) 175 A at 2.5 kHz (normal duty) regenerative mode 145 A at 2.5 kHz (heavy duty) regenerative mode |
|
maximum transient current |
217.5 A during 60 s (heavy duty)
210 A during 60 s (normal duty) 210 A during 60 s regenerative mode (normal duty) 217.5 A during 60 s regenerative mode (heavy duty) |
|
speed drive output frequency |
0.1...599 Hz
|
|
nominal switching frequency |
2.5 kHz
|
|
switching frequency |
2...4.9 kHz adjustable with derating factor
|
|
safety function |
STO (safe torque off) SIL 3
|
|
communication port protocol |
Ethernet/IP
Modbus serial Modbus TCP |
|
option module |
Slot A : communication module for Profibus DP V1
Slot A : communication module for Profinet Slot A : communication module for DeviceNet Slot A : communication module for CANopen daisy chain RJ45 Slot A : communication module for CANopen SUB-D 9 Slot A : communication module for CANopen screw terminals Slot A : communication module for EtherCAT Slot A/slot B/slot C : digital and analog I/O extension module Slot A/slot B/slot C : output relay extension module Slot B : analog encoder interface module Slot B : resolver encoder interface module Slot B : digital encoder interface module for 5/12 V |
motor slip compensation |
Can be suppressed
Automatic whatever the load Adjustable Not available in permanent magnet motor law |
|
---|---|---|
acceleration and deceleration ramps |
Linear adjustable separately from 0.01...9999 s
|
|
protection type |
Safe torque off motor
Motor phase break motor Safe torque off drive Overheating drive Short-circuit protection drive Motor phase break drive Overspeed drive Break on the control circuit drive Overvoltages on the DC bus drive Overload of output voltage drive Line supply overvoltage drive Line supply phase loss drive Line supply undervoltage drive Overcurrent between output phases and earth drive Thermal protection motor Thermal protection drive |
|
frequency resolution |
0.012/50 Hz analog input
0.1 Hz display unit |
|
electrical connection |
Removable screw terminals 0.5...1.5 mm² AWG 20...AWG 16 control
Screw terminal line side M10 x 2 bars motor |
|
connector type |
2 RJ45 for Ethernet IP/Modbus TCP on terminal
1 RJ45 for Modbus serial on terminal |
|
physical interface |
2-wire RS 485 for Modbus serial
|
|
transmission frame |
RTU for Modbus serial
|
|
transmission rate |
10/100 Mbit/s for Ethernet IP/Modbus TCP
4.8, 9.6, 19.2, 38.4 kbit/s for Modbus serial |
|
data format |
8 bits, configurable odd, even or no parity for Modbus serial
|
|
type of polarization |
No impedance for Modbus serial
|
|
number of addresses |
For Modbus serial
|
|
method of access |
Slave for Modbus TCP
|
|
analogue input type |
Software-configurable voltage AI1, AI3 0...10 V DC 30 kOhm 12
bits
Software-configurable current AI1, AI3 0...20 mA/4...20 mA 250 Ohm 12 bits Software-configurable voltage AI2 +/- 10 V DC 30 kOhm 12 bits Software-configurable voltage AI2 0...10 V DC 30 kOhm 12 bits |
THDI |
<= 5 % full load conforming to IEEE 519
|
|
---|---|---|
electromagnetic compatibility |
1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to
IEC 61000-4-5
Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6 |
|
pollution degree |
2 EN/IEC 61800-5-1
|
|
vibration resistance |
1.5 mm peak to peak 2...13 Hz IEC 60068-2-6
0.5 gn 13...200 Hz IEC 60068-2-6 |
|
shock resistance |
4 gn 11 ms IEC 60068-2-27
|
|
relative humidity |
5...95 % without condensation conforming to IEC 60068-2-3
|
|
ambient air temperature for operation |
40...50 °C with derating factor
-5...40 °C without |
|
ambient air temperature for storage |
-40...70 °C
|
|
operating altitude |
<= 2000 m with current derating above 1000m
|
|
environmental characteristic |
Chemical pollution resistance class 3C3 EN/IEC 60721-3-3
Dust pollution resistance class 3S3 EN/IEC 60721-3-3 |
|
standards |
EN/IEC 61800-3
EN/IEC 61800-5-1 IEC 61000-3-12 IEC 60721-3 IEC 61508 IEC 13849-1 |
|
product certifications |
TÜV
REACH CUL UL |
|
marking |
CE
|
Schneider ATV9B0C16Q6 Altivar Process Modular Variable Speed Drive - Low Harmonic/Regen
- Brand: Schneider
- Product Code: ATV9B0C16Q6
- Availability: 1000
Tags: Schneider ATV9B0C16Q6, Altivar Process Modular, Variable Speed Drive, Low Harmonic Drive, Regenerative Drive, ATV900 Series, Industrial Drive, Energy Efficient, Regenerative Braking