Schneider ATV9B0C25N6 Variable Speed Drive Altivar Process Modular:
The Schneider ATV9B0C25N6 Variable Speed Drive Altivar Process Modular is an exemplary innovation in the realm of industrial automation and control. Engineered as part of the renowned ATV900 series, this drive stands as a testament to precision, efficiency, and adaptability in power management and control.
Unparalleled Performance: At the heart of this system lies exceptional adaptability and performance, catering to diverse industrial applications with unparalleled accuracy and efficiency. Its cutting-edge technology ensures optimized operations, enabling seamless control over motors, maximizing productivity while minimizing energy consumption.
Low Harmonic/Regen Drive: A distinguishing feature of the ATV9B0C25N6 is its low harmonic/regenerative capability. The drive excels in mitigating harmonic distortions, ensuring a cleaner power supply and reducing electromagnetic interference, thereby prolonging equipment lifespan and ensuring operational reliability.
Modular Design: Crafted with a modular design ethos, the Altivar Process Modular drive offers flexibility and scalability, allowing seamless integration into varying operational setups. Its modular construction simplifies maintenance and future expansions, providing a cost-effective and customizable solution for evolving industrial needs.
Advanced Control Capabilities: Equipped with advanced control capabilities, this drive boasts precise speed and torque control, enhancing motor performance and optimizing process efficiency. The integrated control features enable swift adaptation to dynamic load changes, ensuring consistent and reliable operations across diverse industrial environments.
Environmental Efficiency: In alignment with eco-conscious initiatives, the ATV9B0C25N6 drive incorporates energy-saving functionalities, contributing to reduced carbon footprint and operational costs. Its intelligent design prioritizes energy efficiency without compromising on performance, making it an ideal choice for sustainable industrial operations.
Seamless Integration and Connectivity: The Altivar Process Modular drive seamlessly integrates with existing automation systems and offers comprehensive connectivity options. Its compatibility with various communication protocols enables effortless integration into Industry 4.0 frameworks, facilitating data exchange and remote monitoring for enhanced operational insights.
Conclusion: The Schneider ATV9B0C25N6 Variable Speed Drive Altivar Process Modular, ATV900, Low Harmonic/Regen Drive is a pinnacle of technological innovation in industrial automation. With its exceptional performance, adaptability, and sustainability features, it stands as a testament to Schneider’s commitment to delivering cutting-edge solutions for optimized industrial operations.
Experience unparalleled precision, efficiency, and adaptability with the ATV9B0C25N6, setting new standards in industrial power management and control.
range of product |
Altivar Process ATV900
|
|
---|---|---|
product or component type |
Variable speed drive
|
|
device short name |
ATV9B0
|
|
variant |
Modular version
|
|
product destination |
Asynchronous motors
Synchronous motors |
|
mounting mode |
Cabinet mount
|
|
kit composition |
Mechanical mounting kits
Power connection Set of fuses 1 control unit 1 front cover 2 power module 200 kW |
|
EMC filter |
Integrated conforming to EN/IEC 61800-3 category C3 with <= 300
m motor cable maxi
|
|
IP degree of protection |
IP00 conforming to IEC 61800-5-1 for IP21 or IP54 cabinet
integration
IP00 conforming to IEC 60529 for IP21 or IP54 cabinet integration |
|
degree of protection |
UL type 1 UL 61800-5-1 cabinet integration
UL type 12 UL 61800-5-1 cabinet integration |
|
type of cooling |
Forced convection
|
|
supply frequency |
50...60 Hz +/- 5 %
|
|
network number of phases |
3 phases
|
|
[Us] rated supply voltage |
500 V - 10...15 %
|
|
motor power kW |
160 kW at 500 V (normal duty)
132 kW at 500 V (heavy duty) 160 kW at 500 V (normal duty) regenerative mode 132 kW at 500 V (heavy duty) regenerative mode |
|
line current |
204 A at 500 V (normal duty)
169 A at 500 V (heavy duty) 167 A at 500 V (normal duty) regenerative mode 137 A at 500 V (heavy duty) regenerative mode |
|
prospective line Isc |
50 kA
|
|
apparent power |
176 kVA at 500 V (normal duty)
146 kVA at 500 V (heavy duty) 145 kVA at 500 V (normal duty) regenerative mode 119 kVA at 500 V (heavy duty) regenerative mode |
|
continuous output current |
275 A at 2.5 kHz (normal duty)
215 A at 2.5 kHz (heavy duty) 275 A at 2.5 kHz (normal duty) regenerative mode 215 A at 2.5 kHz (heavy duty) regenerative mode |
|
maximum transient current |
330 A during 60 s (normal duty)
322.5 A during 60 s (heavy duty) 330 A during 60 s regenerative mode (normal duty) 322.5 A during 60 s regenerative mode (heavy duty) |
|
speed drive output frequency |
0.1...599 Hz
|
|
nominal switching frequency |
2.5 kHz
|
|
switching frequency |
2...4.9 kHz adjustable with derating factor
|
|
safety function |
STO (safe torque off) SIL 3
|
|
communication port protocol |
Ethernet/IP
Modbus serial Modbus TCP |
|
option module |
Slot A : communication module for Profibus DP V1
Slot A : communication module for Profinet Slot A : communication module for DeviceNet Slot A : communication module for CANopen daisy chain RJ45 Slot A : communication module for CANopen SUB-D 9 Slot A : communication module for CANopen screw terminals Slot A : communication module for EtherCAT Slot A/slot B/slot C : digital and analog I/O extension module Slot A/slot B/slot C : output relay extension module Slot B : analog encoder interface module Slot B : resolver encoder interface module Slot B : digital encoder interface module for 5/12 V |
motor slip compensation |
Adjustable
Automatic whatever the load Can be suppressed Not available in permanent magnet motor law |
|
---|---|---|
acceleration and deceleration ramps |
Linear adjustable separately from 0.01...9999 s
|
|
protection type |
Safe torque off motor
Motor phase break motor Safe torque off drive Overheating drive Short-circuit protection drive Motor phase break drive Overspeed drive Break on the control circuit drive Overvoltages on the DC bus drive Overload of output voltage drive Line supply overvoltage drive Line supply phase loss drive Line supply undervoltage drive Overcurrent between output phases and earth drive Thermal protection motor Thermal protection drive |
|
frequency resolution |
0.012/50 Hz analog input
0.1 Hz display unit |
|
electrical connection |
Removable screw terminals 0.5...1.5 mm² AWG 20...AWG 16 control
Screw terminal line side M10 x 2 bars motor |
|
connector type |
2 RJ45 for Ethernet IP/Modbus TCP on terminal
1 RJ45 for Modbus serial on terminal |
|
physical interface |
2-wire RS 485 for Modbus serial
|
|
transmission frame |
RTU for Modbus serial
|
|
transmission rate |
10/100 Mbit/s for Ethernet IP/Modbus TCP
4.8, 9.6, 19.2, 38.4 kbit/s for Modbus serial |
|
data format |
8 bits, configurable odd, even or no parity for Modbus serial
|
|
type of polarization |
No impedance for Modbus serial
|
|
number of addresses |
For Modbus serial
|
|
method of access |
Slave for Modbus TCP
|
|
analogue input type |
Software-configurable voltage AI1, AI3 0...10 V DC 30 kOhm 12
bits
Software-configurable current AI1, AI3 0...20 mA/4...20 mA 250 Ohm 12 bits Software-configurable voltage AI2 +/- 10 V DC 30 kOhm 12 bits Software-configurable voltage AI2 0...10 V DC 30 kOhm 12 bits |
THDI |
<= 5 % full load conforming to IEEE 519
|
|
---|---|---|
electromagnetic compatibility |
1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to
IEC 61000-4-5
Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6 |
|
pollution degree |
2 EN/IEC 61800-5-1
|
|
vibration resistance |
1.5 mm peak to peak 2...13 Hz IEC 60068-2-6
0.5 gn 13...200 Hz IEC 60068-2-6 |
|
shock resistance |
4 gn 11 ms IEC 60068-2-27
|
|
relative humidity |
5...95 % without condensation conforming to IEC 60068-2-3
|
|
ambient air temperature for operation |
40...50 °C with derating factor
-5...40 °C without |
|
ambient air temperature for storage |
-40...70 °C
|
|
operating altitude |
<= 2000 m with current derating above 1000m
|
|
environmental characteristic |
Chemical pollution resistance class 3C3 EN/IEC 60721-3-3
Dust pollution resistance class 3S3 EN/IEC 60721-3-3 |
|
standards |
EN/IEC 61800-3
EN/IEC 61800-5-1 IEC 61000-3-12 IEC 60721-3 IEC 61508 IEC 13849-1 |
|
product certifications |
CUL
TÜV UL REACH |
|
marking |
CE
|