Schneider ATV9B0C25T6 Variable Speed Drive - Altivar Process Modular ATV900
Product Overview: The Schneider ATV9B0C25T6 Variable Speed Drive, part of the Altivar Process Modular ATV900 series, represents the pinnacle of performance in industrial variable speed drives. Engineered for superior efficiency, this drive integrates advanced low harmonic and regenerative technologies, making it ideal for demanding applications where power quality and energy savings are paramount.
Technical Specifications:
- Model: ATV9B0C25T6
- Type: Variable Speed Drive
- Series: Altivar Process Modular ATV900
- Voltage: 400V
- Power Rating: 250 kW
- Frequency Range: 0-600 Hz
- Protection Rating: IP20
- Harmonic Filtering: Low Harmonic
- Regenerative Capabilities: Yes
Key Features:
Low Harmonic Distortion: The ATV9B0C25T6 is designed with advanced harmonic filtering technology to minimize distortion and improve the overall power quality of your electrical system. This feature not only ensures compliance with stringent regulations but also enhances the reliability and efficiency of your operations.
Regenerative Drive Technology: This drive incorporates regenerative braking capabilities, enabling it to recover and reuse energy during deceleration phases. This reduces overall energy consumption and operational costs while extending the lifespan of mechanical components.
Enhanced Performance: With a robust power rating of 250 kW and a frequency range up to 600 Hz, the ATV9B0C25T6 delivers exceptional performance across a wide range of applications. Its precise control over speed and torque ensures optimal operation in complex processes.
Flexible Integration: The ATV9B0C25T6 is engineered for easy integration into various industrial environments. Its modular design allows for scalable and customizable solutions, accommodating different installation configurations and system requirements.
User-Friendly Interface: Equipped with a comprehensive user interface, this drive offers intuitive programming and monitoring capabilities. The interface provides real-time feedback, simplifying setup and maintenance while improving overall system management.
Reliability and Durability: Built to withstand harsh operating conditions, the ATV9B0C25T6 ensures long-term reliability and minimal downtime. Its robust construction and high-quality components guarantee consistent performance and durability.
Applications: The Schneider ATV9B0C25T6 is ideal for a wide range of industrial applications, including:
- HVAC systems
- Pump and fan control
- Process automation
- Material handling
- Water and wastewater management
range of product |
Altivar Process ATV900
|
|
---|---|---|
product or component type |
Variable speed drive
|
|
device short name |
ATV9B0
|
|
variant |
Modular version
|
|
product destination |
Synchronous motors
Asynchronous motors |
|
mounting mode |
Cabinet mount
|
|
kit composition |
Mechanical mounting kits
Power connection Set of fuses 1 control unit 1 front cover 2 power module 200 kW |
|
EMC filter |
Integrated conforming to EN/IEC 61800-3 category C3 with <= 300
m motor cable maxi
|
|
IP degree of protection |
IP00 conforming to IEC 61800-5-1 for IP21 or IP54 cabinet
integration
IP00 conforming to IEC 60529 for IP21 or IP54 cabinet integration |
|
degree of protection |
UL type 1 UL 61800-5-1 cabinet integration
UL type 12 UL 61800-5-1 cabinet integration |
|
type of cooling |
Forced convection
|
|
supply frequency |
50...60 Hz +/- 5 %
|
|
network number of phases |
3 phases
|
|
[Us] rated supply voltage |
600 V - 10...15 %
|
|
motor power hp |
250 hp at 600 V (normal duty)
200 hp at 600 V (heavy duty) 250 hp at 600 V (normal duty) regenerative mode 200 hp at 600 V (heavy duty) regenerative mode |
|
line current |
199 A at 600 V (normal duty)
160 A at 600 V (heavy duty) 162 A at 600 V (normal duty) regenerative mode 129 A at 600 V (heavy duty) regenerative mode |
|
prospective line Isc |
50 kA
|
|
apparent power |
166 kVA at 600 V (heavy duty)
207 kVA at 600 V (normal duty) 169 kVA at 600 V (normal duty) regenerative mode 134 kVA at 600 V (heavy duty) regenerative mode |
|
continuous output current |
275 A at 2.5 kHz (normal duty)
215 A at 2.5 kHz (heavy duty) 275 A at 2.5 kHz (normal duty) regenerative mode 215 A at 2.5 kHz (heavy duty) regenerative mode |
|
maximum transient current |
330 A during 60 s (normal duty)
322.5 A during 60 s (heavy duty) 330 A during 60 s regenerative mode (normal duty) 322.5 A during 60 s regenerative mode (heavy duty) |
|
speed drive output frequency |
0.1...599 Hz
|
|
nominal switching frequency |
2.5 kHz
|
|
switching frequency |
2...4.9 kHz adjustable with derating factor
|
|
safety function |
STO (safe torque off) SIL 3
|
|
communication port protocol |
Ethernet/IP
Modbus serial Modbus TCP |
|
option module |
Slot A : communication module for Profibus DP V1
Slot A : communication module for Profinet Slot A : communication module for DeviceNet Slot A : communication module for CANopen daisy chain RJ45 Slot A : communication module for CANopen SUB-D 9 Slot A : communication module for CANopen screw terminals Slot A : communication module for EtherCAT Slot A/slot B/slot C : digital and analog I/O extension module Slot A/slot B/slot C : output relay extension module Slot B : analog encoder interface module Slot B : resolver encoder interface module Slot B : digital encoder interface module for 5/12 V |
motor slip compensation |
Can be suppressed
Not available in permanent magnet motor law Automatic whatever the load Adjustable |
|
---|---|---|
acceleration and deceleration ramps |
Linear adjustable separately from 0.01...9999 s
|
|
protection type |
Safe torque off motor
Motor phase break motor Safe torque off drive Overheating drive Short-circuit protection drive Motor phase break drive Overspeed drive Break on the control circuit drive Overvoltages on the DC bus drive Overload of output voltage drive Line supply overvoltage drive Line supply phase loss drive Line supply undervoltage drive Overcurrent between output phases and earth drive Thermal protection motor Thermal protection drive |
|
frequency resolution |
0.012/50 Hz analog input
0.1 Hz display unit |
|
electrical connection |
Removable screw terminals 0.5...1.5 mm² AWG 20...AWG 16 control
Screw terminal line side M10 x 2 bars motor |
|
connector type |
2 RJ45 for Ethernet IP/Modbus TCP on terminal
1 RJ45 for Modbus serial on terminal |
|
physical interface |
2-wire RS 485 for Modbus serial
|
|
transmission frame |
RTU for Modbus serial
|
|
transmission rate |
10/100 Mbit/s for Ethernet IP/Modbus TCP
4.8, 9.6, 19.2, 38.4 kbit/s for Modbus serial |
|
data format |
8 bits, configurable odd, even or no parity for Modbus serial
|
|
type of polarization |
No impedance for Modbus serial
|
|
number of addresses |
For Modbus serial
|
|
method of access |
Slave for Modbus TCP
|
|
analogue input type |
Software-configurable voltage AI1, AI3 0...10 V DC 30 kOhm 12
bits
Software-configurable current AI1, AI3 0...20 mA/4...20 mA 250 Ohm 12 bits Software-configurable voltage AI2 +/- 10 V DC 30 kOhm 12 bits Software-configurable voltage AI2 0...10 V DC 30 kOhm 12 bits |
THDI |
<= 5 % full load conforming to IEEE 519
|
|
---|---|---|
electromagnetic compatibility |
1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to
IEC 61000-4-5
Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6 |
|
pollution degree |
2 EN/IEC 61800-5-1
|
|
vibration resistance |
1.5 mm peak to peak 2...13 Hz IEC 60068-2-6
0.5 gn 13...200 Hz IEC 60068-2-6 |
|
shock resistance |
4 gn 11 ms IEC 60068-2-27
|
|
relative humidity |
5...95 % without condensation conforming to IEC 60068-2-3
|
|
ambient air temperature for operation |
40...50 °C with derating factor
-5...40 °C without |
|
ambient air temperature for storage |
-40...70 °C
|
|
operating altitude |
<= 2000 m with current derating above 1000m
|
|
environmental characteristic |
Chemical pollution resistance class 3C3 EN/IEC 60721-3-3
Dust pollution resistance class 3S3 EN/IEC 60721-3-3 |
|
standards |
EN/IEC 61800-3
EN/IEC 61800-5-1 IEC 61000-3-12 IEC 60721-3 IEC 61508 IEC 13849-1 UL 61800-5-1 |
|
product certifications |
TÜV
REACH CUL UL |
|
marking |
CE
|