Schneider HMISAC Rear Module Controller Panel – 16 Digital Inputs / 10 Digital Outputs
Overview
The Schneider HMISAC Rear Module Controller Panel is a high-performance, robust control solution designed to enhance the functionality and efficiency of industrial automation systems. This rear module offers a comprehensive set of features with 16 digital inputs and 10 digital outputs, providing versatile and reliable control for complex industrial processes.
Key Features
Digital Inputs (16): The HMISAC panel features 16 high-precision digital inputs, allowing for the seamless integration of various sensors and input devices. These inputs are designed to handle high-speed signals and ensure accurate data acquisition in real-time.
Digital Outputs (10): Equipped with 10 digital outputs, this module facilitates precise control over external devices such as actuators, relays, and alarms. The outputs are engineered to deliver reliable performance under demanding operational conditions.
Modular Design: The HMISAC rear module's modular design enables easy installation and maintenance, ensuring minimal downtime and increased operational efficiency. Its compatibility with Schneider's HMI range allows for flexible configuration and scalability.
High Durability: Constructed with high-quality materials and advanced engineering, this module is built to withstand harsh industrial environments. Its rugged design ensures long-term reliability and reduces the need for frequent replacements.
Enhanced Connectivity: The panel supports a wide range of industrial communication protocols, facilitating seamless integration with various automation systems and enhancing overall system interoperability.
Compact and Efficient: Designed to optimize space and improve system organization, the HMISAC rear module is compact yet powerful, offering high-density functionality in a streamlined form factor.
Technical Specifications
Digital Inputs:
- Number of Inputs: 16
- Input Type: Digital
- Input Voltage Range: [Specify Voltage Range]
Digital Outputs:
- Number of Outputs: 10
- Output Type: Digital
- Output Voltage Range: [Specify Voltage Range]
- Output Current Rating: [Specify Current Rating]
Operating Temperature Range: [Specify Temperature Range]
Dimensions: [Specify Dimensions]
Weight: [Specify Weight]
Enclosure Rating: [Specify Enclosure Rating]
Applications
The Schneider HMISAC Rear Module Controller Panel is ideal for use in various industrial applications, including:
- Manufacturing Automation: Facilitates precise control and monitoring of production processes.
- Process Control: Enhances the management of industrial processes by integrating diverse input and output devices.
- Building Automation: Supports automation systems in commercial and residential buildings for efficient operation and control.
Why Choose Schneider HMISAC?
The Schneider HMISAC Rear Module Controller Panel stands out for its exceptional performance, reliability, and ease of integration. Its robust design and advanced features make it a valuable asset for any industrial automation setup, ensuring optimal control and operational efficiency.
Optimize Your Industrial Automation Today
Elevate your control system with the Schneider HMISAC Rear Module Controller Panel. Explore its advanced features and discover how it can transform your automation processes. For more information or to request a quote, contact us today!
range of product |
Magelis SCU
|
|
---|---|---|
product or component type |
Controller
|
|
device presentation |
Basic element
|
supply |
External source
|
|
---|---|---|
[Us] rated supply voltage |
24 V at 20.4...28.8 V DC
|
|
immunity to microbreaks |
<= 10 ms
|
|
inrush current |
<= 30 A
|
|
power consumption in W |
15 W
|
|
local signalling |
No indicator
|
|
number of pages |
Limited by internal memory capacity
|
|
software designation |
SoMachine
|
|
operating system |
Magelis
|
|
processor name |
CPU RISC
|
|
processor frequency |
333 MHz
|
|
memory description |
128 MB flash memory, type: NAND
128 kB internal data storage memory, type: FRAM 128 MB application run memory, type: DRAM |
|
integrated connection type |
1 RJ45 connector serial link with RS232/RS485 interface at <=
115.2 kbits/s
1 RJ45 connector Ethernet TCP/IP 1 USB 2.0 type mini B 1 USB 2.0 type A SUB-D 9 connector CANopen master bus |
|
realtime clock |
Built-in
|
|
downloadable protocols |
CANopen
Modbus TCP/IP Modbus |
|
fixing mode |
By 1 nut - diameter: Ø 22 mm, mounting on: 1...6 mm thick panel
|
|
enclosure material |
PC/PBT
|
|
shock resistance |
147 m/s² (duration=11 ms) conforming to IEC 60068-2-27 on DIN
rail
294 m/s² (duration=6 ms) conforming to IEC 60068-2-27 on panel mounting |
|
vibration resistance |
+/- 3.5 mm (f=5...9 Hz) conforming to IEC 60068-2-6
1 gn (f=9...150 Hz) conforming to IEC 60068-2-6 |
|
electromagnetic compatibility |
Electrostatic discharge immunity test - test level: 8 kV, air
discharge conforming to IEC 61000-4-2
Electrostatic discharge immunity test - test level: 6 kV, contact discharge conforming to IEC 61000-4-2 Susceptibility to electromagnetic fields - test level: 10 V/m, 80 MHz...3 GHz conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test - test level: 2 kV, power lines conforming to IEC 61000-4-4 Electrical fast transient/burst immunity test - test level: 1 kV, between analogue I/O and operating voltage conforming to IEC 61000-4-4 Electrical fast transient/burst immunity test - test level: 2 kV, relay wires conforming to IEC 61000-4-4 Electrical fast transient/burst immunity test - test level: 1 kV, Ethernet line conforming to IEC 61000-4-4 Electrical fast transient/burst immunity test - test level: 1 kV, COM line conforming to IEC 61000-4-4 Electrical fast transient/burst immunity test - test level: 1 kV, CAN line conforming to IEC 61000-4-4 Surge immunity test - test level: 2 kV, power supply (common mode) conforming to IEC 61000-4-5 Surge immunity test - test level: 1 kV, power supply (differential mode) conforming to IEC 61000-4-5 Surge immunity test - test level: 1 kV common mode, digital I/O conforming to IEC 61000-4-5 Surge immunity test - test level: 0.5 kV differential mode, digital I/O conforming to IEC 61000-4-5 Conducted RF disturbances - test level: 10 V, 0.15...80 MHz conforming to IEC 61000-4-6 Conducted emission - test level: 150 kHz...30 MHz conforming to EN 55011 Radiated emission - test level: 30 MHz...1 GHz conforming to EN 55011 |
|
discrete input number |
2 for fast input (normal mode) conforming to IEC 61131-2 Type 1
14 for digital input conforming to IEC 61131-2 Type 1 |
|
discrete input voltage |
24 V DC discrete input logic:sink or source (positive/negative)
|
|
number of common point |
1 for fast input (HSC mode)
2 for digital input |
|
discrete input current |
7.83 mA for fast input
5 mA for digital |
|
input impedance |
4.7 kOhm
2.81 kOhm |
|
sensor power supply |
15...28.8 V DC, voltage (state 1): >= 15 V, current (state 1):
>= 5 mA, voltage (state 0): <= 5 V, current (state 0): <= 1.5 mA
15...28.8 V DC, voltage (state 1): >= 15 V, current (state 1): >= 2.5 mA, voltage (state 0): <= 5 V, current (state 0): <= 1 mA |
|
configurable filtering time |
0 ms no filter (none)
0.004...0.04 ms bounce filter (latch/event and cumulative filter by step Nx0.5ms (64>=N>=2)) 3...12 ms integrator (none/run/stop) |
|
input frequency |
100 kHz for fast input (encoder mode) - control type A/B
100 kHz for fast input - control type single phase 100 kHz for fast input - control type pulse/direction |
|
cable distance between devices |
Shielded cable: 10 m for fast input
Shielded cable: 100 m for digital input Unshielded cable: 50 m for digital input |
|
connection pitch |
3.5 mm
|
|
overvoltage protection |
With
|
|
isolation between channels and internal logic |
500 V DC
|
|
isolation between channels |
None
|
|
discrete output number |
2 fast output (normal mode), output logic: source
8 digital output, output logic: source |
|
discrete output voltage |
24 V DC (voltage limit: 19.2...28.8 V) with transistor discrete
output(s)
24 V DC (voltage limit: 5...30 V) with relay discrete output(s) 220 V AC (voltage limit: 100...250 V) with relay discrete output(s) |
|
input/output number |
2 for fast input, terminal(s): FI0...FI1
14 for digital input, terminal(s): DI0...DI13 2 for fast output, terminal(s): FQ0...FQ1 8 for digital output, terminal(s): DQ0...DQ7 |
|
discrete output current |
300 mA, response time 2 ms for fast output (normal mode)
50 mA, response time 2 ms for fast output (PWM or PTO mode) 2 A (current per output common:4 A), response time 5 ms with opening contact for digital output 2 A (current per output common:4 A), response time 2 ms with closing contact for digital output |
|
insulation resistance |
> 10 MOhm between the I/O and internal logic
> 10 MOhm between power supply and earth |
|
output frequency |
<= 100 kHz for fast output (PTO mode)
<= 1 kHz for fast output (PWM mode) |
|
absolute accuracy error |
+/- 0.1 % of full scale of cyclic ratio 1...99% for fast output
(PWM or PTO mode)
1 % of full scale of cyclic ratio 1...99% for fast output (PWM or PTO mode) +/- 5 % of full scale of cyclic ratio 10...90% for fast output (PWM or PTO mode) +/- 10 % of full scale of cyclic ratio 20...80% for fast output (PWM or PTO mode) +/- 15 % of full scale of cyclic ratio 30...70% for fast output (PWM or PTO mode) |
|
height |
50.65 mm
|
|
width |
128 mm
|
|
depth |
102 mm
|
|
product weight |
0.359 kg
|
standards |
CSA C22.2 No 213 Class I Division 2
UL 508 WEEE directive 2002/96/EC EN 61131-2 ANSI/ISA 12-12-01 RoHS compliant IEC 61000-6-2 RoHS China SJ/T 11363-2006 FCC Class A |
|
---|---|---|
product certifications |
CUL 1604 Class 1 Division 2
GOST KCC CULus 508 C-Tick CULus CSA 22-2 No 142 |
|
marking |
CE
|
|
ambient air temperature for operation |
0...50 °C
|
|
ambient air temperature for storage |
-20...60 °C
|
|
relative humidity |
5...85 % without condensation
|
|
operating altitude |
<= 2000 m
|
|
storage altitude |
0...10000 m
|
|
maximum pressure |
800...1114 hPa
|
|
IP degree of protection |
IP65 for front panel conforming to IEC 60529
IP20 for rear panel conforming to IEC 60529 |
|
NEMA degree of protection |
NEMA 4X for front panel
|
|
pollution degree |
2 conforming to IEC 60664
|
|
environmental characteristic |
Corrosive gas free
|