Schneider TM221C16U Controller – M221-16IO TR.NPN
Overview: The Schneider TM221C16U Controller is an advanced programmable logic controller (PLC) designed for precise and reliable control in industrial automation applications. As part of the M221 series, this controller offers exceptional performance with its 16 digital input/output (I/O) channels, featuring NPN transistor outputs. It is engineered to meet the demands of modern automation systems, providing a versatile and robust solution for a wide range of control tasks.
Key Features:
Digital I/O Configuration: The TM221C16U is equipped with 16 I/O channels, including 8 digital inputs and 8 NPN transistor outputs. This configuration allows for flexible integration and control of various field devices and sensors.
High-Speed Processing: With its powerful processing capabilities, the TM221C16U ensures fast and accurate execution of control algorithms and real-time responses, enhancing the efficiency of your automation processes.
Versatile Communication Options: The controller supports multiple communication protocols, including Modbus, which facilitates seamless integration with other Schneider Electric devices and third-party systems. This ensures easy connectivity and interoperability within your automation network.
Compact and Robust Design: The compact form factor of the TM221C16U makes it ideal for space-constrained installations. Its robust construction ensures reliable operation in demanding industrial environments, with protection against dust and moisture.
User-Friendly Programming: Schneider's M221 series controllers are compatible with the EcoStruxure Machine Expert (formerly SoMachine) programming software. This intuitive software provides a graphical programming environment, simplifying the development of control applications and reducing programming time.
Enhanced Diagnostics: The TM221C16U features advanced diagnostic capabilities, allowing for real-time monitoring and troubleshooting of system performance. This helps in maintaining system uptime and reducing maintenance costs.
Energy Efficiency: Designed with energy efficiency in mind, the TM221C16U controller minimizes power consumption while delivering high performance, contributing to overall operational cost savings.
Applications:
The Schneider TM221C16U Controller is ideal for a variety of industrial automation applications, including:
- Manufacturing Processes: Efficiently manage and control manufacturing equipment and processes, ensuring optimal performance and quality.
- Packaging Systems: Integrate with packaging machinery to streamline operations and enhance productivity.
- Building Automation: Oversee and control HVAC systems, lighting, and other building services for improved energy management and operational efficiency.
- Material Handling: Coordinate conveyors, lifts, and other material handling equipment to optimize logistics and workflow.
Specifications:
- Model: TM221C16U
- Series: M221
- I/O Channels: 16 (8 digital inputs, 8 NPN transistor outputs)
- Communication Protocol: Modbus
- Programming Software: EcoStruxure Machine Expert
- Protection Rating: IP20
- Dimensions: Compact design suitable for limited space
Why Choose Schneider TM221C16U:
Choosing the Schneider TM221C16U Controller ensures you benefit from Schneider Electric’s renowned quality and reliability in industrial automation. With its robust features, user-friendly programming, and versatile communication options, this controller is an excellent choice for enhancing the performance and efficiency of your automation systems.
Order Now:
Enhance your automation capabilities with the Schneider TM221C16U Controller. Contact us today to learn more or to place your order.
range of product |
Modicon M221
|
|
---|---|---|
product or component type |
Logic controller
|
|
[Us] rated supply voltage |
24 V DC
|
|
discrete input number |
9 discrete input conforming to IEC 61131-2 Type 1 including 4
fast input
|
|
analogue input number |
2 at input range: 0...10 V
|
|
discrete output type |
Transistor
|
|
discrete output number |
7 transistor including 2 fast output
|
|
discrete output voltage |
24 V DC
|
|
discrete output current |
0.5 A
|
discrete I/O number |
16
|
|
---|---|---|
number of I/O expansion module |
<= 4 for transistor output
<= 4 for relay output |
|
supply voltage limits |
20.4...28.8 V
|
|
inrush current |
<= 35 A
|
|
power consumption in W |
<= 10 W at 24 V with max number of I/O expansion module
<= 3.9 W at 24 V without I/O expansion module |
|
power supply output current |
0.325 A at 5 V for expansion bus
0.15 A at 24 V for expansion bus |
|
discrete input logic |
Sink or source (positive/negative)
|
|
discrete input voltage |
24 V
|
|
discrete input voltage type |
DC
|
|
analogue input resolution |
10 bits
|
|
LSB value |
10 mV
|
|
conversion time |
1 ms per channel + 1 controller cycle time for analog input
|
|
permitted overload on inputs |
+/- 30 V DC for analog input with 5 min maximum
+/- 13 V DC for analog input permanent |
|
voltage state 1 guaranteed |
>= 15 V for input
|
|
voltage state 0 guaranteed |
<= 5 V for input
|
|
discrete input current |
7 mA for discrete input
5 mA for fast input |
|
input impedance |
4.9 kOhm for fast input
3.4 kOhm for discrete input 100 kOhm for analog input |
|
response time |
35 µs turn-off operation for input; I2...I5 terminal
5 µs turn-on operation for fast input; I0, I1, I6, I7 terminal 35 µs turn-on operation for input; other terminals terminal 5 µs turn-off operation for fast input; I0, I1, I6, I7 terminal 100 µs turn-off operation for input; other terminals terminal 5 µs turn-on, turn-off operation for output; Q0...Q1 terminal 50 µs turn-on, turn-off operation for output; Q2...Q3 terminal 300 µs turn-on, turn-off operation for output; other terminals terminal |
|
configurable filtering time |
0 ms for input
12 ms for input 3 ms for input |
|
discrete output logic |
Negative logic (sink)
|
|
current per output common |
3.5 A
|
|
output frequency |
100 kHz for fast output (PWM/PLS mode) at Q0...Q1 termnal
5 kHz for output at Q2...Q3 termnal 0.1 kHz for output at Q4...Q6 termnal |
|
absolute accuracy error |
+/- 1 % of full scale for analog input
|
|
leakage current |
0.1 mA for transistor output
|
|
voltage drop |
<= 1 V
|
|
mechanical durability |
>= 20000000 cycles for transistor output
|
|
tungsten load |
<= 12 W for output and fast output
|
|
protection type |
Without protection
|
|
memory capacity |
256 kB for user application and data RAM with 10000 instructions
256 kB for internal variables RAM |
|
data backed up |
256 kB built-in flash memory for backup of application and data
|
|
data storage equipment |
2 GB SD card optional
|
|
battery type |
BR2032 lithium non-rechargeable, battery life: 4 yr
|
|
backup time |
1 year at 25 °C by interruption of power supply
|
|
execution time for 1 KInstruction |
0.3 ms for event and periodic task
|
|
execution time per instruction |
0.2 µs Boolean
|
|
exct time for event task |
60 µs response time
|
|
maximum size of object areas |
8000 %MW memory words
255 %C counters 512 %KW constant words 255 %TM timers 512 %M memory bits |
|
realtime clock |
With
|
|
clock drift |
<= 30 s/month at 25 °C
|
|
regulation loop |
Adjustable PID regulator up to 14 simultaneous loops
|
|
positioning functions |
Position PTO 2 axe(s) pulse/direction mode (100 kHz)
Position PTO 1 axe(s) CW/CCW mode (100 kHz) |
|
function available |
PLS
PWM Frequency generator |
|
counting input number |
4 fast input (HSC mode) (counting frequency: 100 kHz), counting
capacity: 32 bits
|
|
counter function |
Single phase
Pulse/direction A/B |
|
integrated connection type |
USB port with connector mini B USB 2.0
Non isolated serial link "serial 1" with connector RJ45 and interface RS485 Non isolated serial link "serial 2" with connector RJ45 and interface RS232/RS485 |
|
supply |
Serial serial link supply at 5 V 200 mA
|
|
transmission rate |
1.2...115.2 kbit/s (115.2 kbit/s by default) for bus length of
15 m - communication protocol: RS485
1.2...115.2 kbit/s (115.2 kbit/s by default) for bus length of 3 m - communication protocol: RS232 480 Mbit/s - communication protocol: USB |
|
communication port protocol |
USB port : USB protocol - SoMachine-Network
Non isolated serial link : Modbus protocol master/slave - RTU/ASCII or SoMachine-Network |
|
local signalling |
1 LED green for SD card access (SD)
1 LED red for BAT 1 LED green for SL1 1 LED green for SL2 1 LED per channel green for I/O state 1 LED red for module error (ERR) 1 LED green for PWR 1 LED green for RUN |
|
electrical connection |
Mini B USB 2.0 connector for a programming terminal
Terminal block, 3 terminal(s) for connecting the 24 V DC power supply Connector, 4 terminal(s) for analogue inputs Removable screw terminal block for inputs Removable screw terminal block for outputs |
|
cable distance between devices |
Shielded cable: 10 m for fast input
Unshielded cable: 30 m for output Unshielded cable: 30 m for digital input Unshielded cable: 1 m for analog input Shielded cable: 3 m for fast output |
|
insulation |
500 V AC between fast input and internal logic
Non-insulated between inputs Non-insulated between analogue inputs 500 V AC between output and internal logic 500 V AC between input and internal logic Non-insulated between analogue input and internal logic |
|
marking |
CE
|
|
mounting support |
Top hat type TH35-15 rail conforming to IEC 60715
Top hat type TH35-7.5 rail conforming to IEC 60715 Plate or panel with fixing kit |
|
height |
90 mm
|
|
depth |
70 mm
|
|
width |
95 mm
|
|
product weight |
0.558 kg
|
standards |
EN/IEC 60664-1
EN/IEC 61131-2 EN/IEC 61010-2-201 |
|
---|---|---|
product certifications |
CSA
IACS E10 DNV-GL ABS cULus EAC RCM LR |
|
environmental characteristic |
Ordinary and hazardous location
|
|
resistance to electrostatic discharge |
4 kV on contact conforming to EN/IEC 61000-4-2
8 kV in air conforming to EN/IEC 61000-4-2 |
|
resistance to electromagnetic fields |
10 V/m ( 80 MHz...1 GHz) conforming to EN/IEC 61000-4-3
3 V/m ( 1.4 GHz...2 GHz) conforming to EN/IEC 61000-4-3 1 V/m ( 2...2.7 GHz) conforming to EN/IEC 61000-4-3 |
|
resistance to magnetic fields |
30 A/m 50/60 Hz conforming to EN/IEC 61000-4-8
|
|
resistance to fast transients |
2 kV for power lines conforming to EN/IEC 61000-4-4
2 kV for relay output conforming to EN/IEC 61000-4-4 1 kV for Ethernet line conforming to EN/IEC 61000-4-4 1 kV for serial link conforming to EN/IEC 61000-4-4 1 kV for I/O conforming to EN/IEC 61000-4-4 |
|
surge withstand |
2 kV for power lines (AC) in common mode conforming to EN/IEC
61000-4-5
2 kV for relay output in common mode conforming to EN/IEC 61000-4-5 1 kV for I/O in common mode conforming to EN/IEC 61000-4-5 1 kV for shielded cable in common mode conforming to EN/IEC 61000-4-5 0.5 kV for power lines (DC) in differential mode conforming to EN/IEC 61000-4-5 1 kV for power lines (AC) in differential mode conforming to EN/IEC 61000-4-5 1 kV for relay output in differential mode conforming to EN/IEC 61000-4-5 0.5 kV for power lines (DC) in common mode conforming to EN/IEC 61000-4-5 |
|
resistance to conducted disturbances |
10 Vrms (0.15...80 MHz) conforming to EN/IEC 61000-4-6
3 Vrms (0.1...80 MHz) conforming to Marine specification (LR, ABS, DNV, GL) 10 Vrms (spot frequency (2, 3, 4, 6.2, 8.2, 12.6, 16.5, 18.8, 22, 25 MHz)) conforming to Marine specification (LR, ABS, DNV, GL) |
|
electromagnetic emission |
Conducted emissions conforming to EN/IEC 55011 power lines (AC),
0.15...0.5 MHz : 79 dBμV/m QP/66 dBμV/m AV
Conducted emissions conforming to EN/IEC 55011 power lines (AC), 0.5...300 MHz : 73 dBμV/m QP/60 dBμV/m AV Conducted emissions conforming to EN/IEC 55011 power lines, 10...150 kHz : 120...69 dBµV/m QP Conducted emissions conforming to EN/IEC 55011 power lines, 1.5...30 MHz : 63 dBμV/m QP Radiated emissions conforming to EN/IEC 55011 class A 10 m, 30...230 MHz : 40 dBμV/m QP Conducted emissions conforming to EN/IEC 55011 power lines, 150...1500 kHz : 79...63 dBμV/m QP Radiated emissions conforming to EN/IEC 55011 class A 10 m, 200...1000 MHz : 47 dBμV/m QP |
|
immunity to microbreaks |
10 ms
|
|
ambient air temperature for operation |
-10...55 °C for horizontal installation
-10...35 °C for vertical installation |
|
ambient air temperature for storage |
-25...70 °C
|
|
relative humidity |
10...95 % without condensation in operation
10...95 % without condensation in storage |
|
IP degree of protection |
IP20 with protective cover in place
|
|
pollution degree |
<= 2
|
|
operating altitude |
0...2000 m
|
|
storage altitude |
0...3000 m
|
|
vibration resistance |
3.5 mm (vibration frequency: 5...8.4 Hz) on symmetrical rail
1 gn (vibration frequency: 8.4...150 Hz) on symmetrical rail 3.5 mm (vibration frequency: 5...8.4 Hz) on panel mounting 1 gn (vibration frequency: 8.4...150 Hz) on panel mounting |
|
shock resistance |
147 m/s² (test wave duration:11 ms)
|
Schneider TM221C16U Controller - M221 16IO TR.NPN
- Brand: Schneider
- Product Code: TM221C16U
- Availability: 1000
Tags: Schneider TM221C16U, M221-16IO TR.NPN, Industrial Automation, PLC Controller, Digital I/O Controller, NPN Transistor Outputs, Compact PLC, Schneider Electric, Automation Systems, Manufacturing Control