Schneider TM221C40U CONTROLLER M221-40IO TR.NPN | Advanced Programmable Logic Controller (PLC) for Precision Automation
Elevate your automation processes with the Schneider TM221C40U CONTROLLER M221-40IO TR.NPN, a state-of-the-art programmable logic controller (PLC) designed for optimal performance in demanding industrial environments. The TM221C40U is engineered to deliver reliable and efficient control with its comprehensive I/O capabilities and advanced features, making it an ideal solution for a variety of automation applications.
Key Features:
High-Performance Processing:
- The TM221C40U boasts a powerful processor that ensures fast and accurate control of complex processes, improving overall system efficiency and responsiveness.
Versatile I/O Configuration:
- With 40 digital I/O points, including both inputs and outputs, this PLC offers exceptional flexibility in interfacing with a wide range of sensors, actuators, and other devices. The combination of transistor (NPN) and relay outputs allows for versatile application in various industrial scenarios.
Integrated Communication Ports:
- The TM221C40U is equipped with built-in communication ports, including Modbus and Ethernet, providing seamless integration with other devices and systems. This facilitates easy network connectivity and data exchange, enhancing your system’s interoperability.
Robust Build Quality:
- Designed to withstand harsh industrial conditions, the TM221C40U features a durable enclosure that protects against dust, moisture, and temperature variations, ensuring long-term reliability and performance.
User-Friendly Programming:
- Schneider’s intuitive programming environment simplifies the configuration and deployment of your automation tasks. The controller supports standard programming languages and offers extensive libraries of pre-configured functions to accelerate development and reduce time-to-market.
Advanced Diagnostics and Monitoring:
- The TM221C40U includes advanced diagnostic tools and real-time monitoring capabilities, allowing for proactive maintenance and swift troubleshooting. This minimizes downtime and ensures continuous operation of your automation system.
Scalable and Flexible:
- The modular design of the TM221C40U allows for easy expansion and adaptation to evolving automation needs. Additional I/O modules and communication interfaces can be seamlessly integrated to enhance system functionality as required.
Applications:
- Manufacturing Automation: Ideal for controlling production lines, conveyor systems, and robotic cells.
- Process Control: Suitable for managing processes in industries such as chemicals, pharmaceuticals, and food and beverage.
- Building Management: Efficiently handles HVAC systems, lighting control, and energy management in commercial buildings.
- Machine Control: Perfect for custom machinery and equipment requiring precise control and monitoring.
Technical Specifications:
- Model: Schneider TM221C40U CONTROLLER M221-40IO TR.NPN
- Inputs/Outputs: 20 Digital Inputs, 20 Digital Outputs (Transistor NPN), Relay Outputs
- Communication Ports: Modbus, Ethernet
- Operating Temperature: -10°C to 55°C
- Power Supply: 24V DC
- Dimensions: [Specify dimensions]
- Weight: [Specify weight]
Why Choose Schneider TM221C40U?
The Schneider TM221C40U CONTROLLER M221-40IO TR.NPN stands out for its high reliability, advanced features, and ease of integration, making it a superior choice for demanding industrial applications. Whether you are upgrading existing systems or developing new automation solutions, this PLC offers the performance and flexibility required to meet your operational goals.
Enhance your automation capabilities with the Schneider TM221C40U and experience unparalleled control and efficiency. For more information or to request a quote, please contact our sales team today.
range of product |
Modicon M221
|
|
---|---|---|
product or component type |
Logic controller
|
|
[Us] rated supply voltage |
24 V DC
|
|
discrete input number |
24 discrete input conforming to IEC 61131-2 Type 1 including 4
fast input
|
|
analogue input number |
2 at input range: 0...10 V
|
|
discrete output type |
Transistor
|
|
discrete output number |
16 transistor including 4 fast output
|
|
discrete output voltage |
24 V DC
|
|
discrete output current |
0.5 A
|
discrete I/O number |
40
|
|
---|---|---|
number of I/O expansion module |
<= 7 for relay output
|
|
supply voltage limits |
20.4...28.8 V
|
|
inrush current |
<= 35 A
|
|
power consumption in W |
<= 4.1 W at 24 V without I/O expansion module
<= 16 W at 24 V with max number of I/O expansion module |
|
power supply output current |
0.52 A at 5 V for expansion bus
0.3 A at 24 V for expansion bus |
|
discrete input logic |
Sink or source (positive/negative)
|
|
discrete input voltage |
24 V
|
|
discrete input voltage type |
DC
|
|
analogue input resolution |
10 bits
|
|
LSB value |
10 mV
|
|
conversion time |
1 ms per channel + 1 controller cycle time for analog input
|
|
permitted overload on inputs |
+/- 30 V DC for analog input with 5 min maximum
+/- 13 V DC for analog input permanent |
|
voltage state 1 guaranteed |
>= 15 V for input
|
|
voltage state 0 guaranteed |
<= 5 V for input
|
|
discrete input current |
7 mA for discrete input
5 mA for fast input |
|
input impedance |
4.9 kOhm for fast input
3.4 kOhm for discrete input 100 kOhm for analog input |
|
response time |
35 µs turn-off operation for input; I2...I5 terminal
5 µs turn-on operation for fast input; I0, I1, I6, I7 terminal 35 µs turn-on operation for input; other terminals terminal 5 µs turn-off operation for fast input; I0, I1, I6, I7 terminal 100 µs turn-off operation for input; other terminals terminal 300 µs turn-on, turn-off operation for output; other terminals terminal 5 µs turn-on, turn-off operation for output; Q0...Q3 terminal |
|
configurable filtering time |
0 ms for input
12 ms for input 3 ms for input |
|
discrete output logic |
Negative logic (sink)
|
|
current per output common |
4 A
|
|
output frequency |
0.1 kHz for output at Q4...Q15 termnal
100 kHz for fast output (PWM/PLS mode) at Q0...Q3 termnal |
|
absolute accuracy error |
+/- 1 % of full scale for analog input
|
|
leakage current |
0.1 mA for transistor output
|
|
voltage drop |
<= 1 V
|
|
mechanical durability |
>= 20000000 cycles for transistor output
|
|
tungsten load |
<= 12 W for output and fast output
|
|
protection type |
Without protection
|
|
memory capacity |
256 kB for user application and data RAM with 10000 instructions
256 kB for internal variables RAM |
|
data backed up |
256 kB built-in flash memory for backup of application and data
|
|
data storage equipment |
2 GB SD card optional
|
|
battery type |
BR2032 lithium non-rechargeable, battery life: 4 yr
|
|
backup time |
1 year at 25 °C by interruption of power supply
|
|
execution time for 1 KInstruction |
0.3 ms for event and periodic task
|
|
execution time per instruction |
0.2 µs Boolean
|
|
exct time for event task |
60 µs response time
|
|
maximum size of object areas |
512 %M memory bits
255 %TM timers 512 %KW constant words 8000 %MW memory words 255 %C counters |
|
realtime clock |
With
|
|
clock drift |
<= 30 s/month at 25 °C
|
|
regulation loop |
Adjustable PID regulator up to 14 simultaneous loops
|
|
positioning functions |
Position PTO 4 axe(s) pulse/direction mode (100 kHz)
Position PTO 2 axe(s) CW/CCW mode (100 kHz) |
|
function available |
Frequency generator
PWM PLS |
|
counting input number |
4 fast input (HSC mode) (counting frequency: 100 kHz), counting
capacity: 32 bits
|
|
counter function |
Pulse/direction
A/B Single phase |
|
integrated connection type |
USB port with connector mini B USB 2.0
Non isolated serial link "serial 1" with connector RJ45 and interface RS485 Non isolated serial link "serial 2" with connector RJ45 and interface RS232/RS485 |
|
supply |
Serial serial link supply at 5 V 200 mA
|
|
transmission rate |
1.2...115.2 kbit/s (115.2 kbit/s by default) for bus length of
15 m - communication protocol: RS485
1.2...115.2 kbit/s (115.2 kbit/s by default) for bus length of 3 m - communication protocol: RS232 480 Mbit/s - communication protocol: USB |
|
communication port protocol |
USB port : USB protocol - SoMachine-Network
Non isolated serial link : Modbus protocol master/slave - RTU/ASCII or SoMachine-Network |
|
local signalling |
1 LED green for SD card access (SD)
1 LED red for BAT 1 LED green for SL1 1 LED green for SL2 1 LED per channel green for I/O state 1 LED red for module error (ERR) 1 LED green for PWR 1 LED green for RUN |
|
electrical connection |
Mini B USB 2.0 connector for a programming terminal
Terminal block, 3 terminal(s) for connecting the 24 V DC power supply Connector, 4 terminal(s) for analogue inputs Removable screw terminal block for inputs Removable screw terminal block for outputs |
|
cable distance between devices |
Shielded cable: 10 m for fast input
Unshielded cable: 30 m for output Unshielded cable: 30 m for digital input Unshielded cable: 1 m for analog input Shielded cable: 3 m for fast output |
|
insulation |
500 V AC between fast input and internal logic
Non-insulated between inputs Non-insulated between analogue inputs 500 V AC between output and internal logic 500 V AC between input and internal logic Non-insulated between analogue input and internal logic |
|
marking |
CE
|
|
mounting support |
Top hat type TH35-15 rail conforming to IEC 60715
Top hat type TH35-7.5 rail conforming to IEC 60715 Plate or panel with fixing kit |
|
height |
90 mm
|
|
depth |
70 mm
|
|
width |
160 mm
|
|
product weight |
0.63 kg
|
standards |
EN/IEC 60664-1
EN/IEC 61010-2-201 EN/IEC 61131-2 |
|
---|---|---|
product certifications |
cULus
RCM IACS E10 ABS CSA LR DNV-GL EAC |
|
environmental characteristic |
Ordinary and hazardous location
|
|
resistance to electrostatic discharge |
4 kV on contact conforming to EN/IEC 61000-4-2
8 kV in air conforming to EN/IEC 61000-4-2 |
|
resistance to electromagnetic fields |
10 V/m ( 80 MHz...1 GHz) conforming to EN/IEC 61000-4-3
3 V/m ( 1.4 GHz...2 GHz) conforming to EN/IEC 61000-4-3 1 V/m ( 2...2.7 GHz) conforming to EN/IEC 61000-4-3 |
|
resistance to magnetic fields |
30 A/m 50/60 Hz conforming to EN/IEC 61000-4-8
|
|
resistance to fast transients |
2 kV for power lines conforming to EN/IEC 61000-4-4
2 kV for relay output conforming to EN/IEC 61000-4-4 1 kV for Ethernet line conforming to EN/IEC 61000-4-4 1 kV for serial link conforming to EN/IEC 61000-4-4 1 kV for I/O conforming to EN/IEC 61000-4-4 |
|
surge withstand |
2 kV for power lines (AC) in common mode conforming to EN/IEC
61000-4-5
2 kV for relay output in common mode conforming to EN/IEC 61000-4-5 1 kV for I/O in common mode conforming to EN/IEC 61000-4-5 1 kV for shielded cable in common mode conforming to EN/IEC 61000-4-5 0.5 kV for power lines (DC) in differential mode conforming to EN/IEC 61000-4-5 1 kV for power lines (AC) in differential mode conforming to EN/IEC 61000-4-5 1 kV for relay output in differential mode conforming to EN/IEC 61000-4-5 0.5 kV for power lines (DC) in common mode conforming to EN/IEC 61000-4-5 |
|
resistance to conducted disturbances |
10 Vrms (0.15...80 MHz) conforming to EN/IEC 61000-4-6
3 Vrms (0.1...80 MHz) conforming to Marine specification (LR, ABS, DNV, GL) 10 Vrms (spot frequency (2, 3, 4, 6.2, 8.2, 12.6, 16.5, 18.8, 22, 25 MHz)) conforming to Marine specification (LR, ABS, DNV, GL) |
|
electromagnetic emission |
Conducted emissions conforming to EN/IEC 55011 power lines (AC),
0.15...0.5 MHz : 79 dBμV/m QP/66 dBμV/m AV
Conducted emissions conforming to EN/IEC 55011 power lines (AC), 0.5...300 MHz : 73 dBμV/m QP/60 dBμV/m AV Conducted emissions conforming to EN/IEC 55011 power lines, 10...150 kHz : 120...69 dBµV/m QP Conducted emissions conforming to EN/IEC 55011 power lines, 1.5...30 MHz : 63 dBμV/m QP Radiated emissions conforming to EN/IEC 55011 class A 10 m, 30...230 MHz : 40 dBμV/m QP Conducted emissions conforming to EN/IEC 55011 power lines, 150...1500 kHz : 79...63 dBμV/m QP Radiated emissions conforming to EN/IEC 55011 class A 10 m, 200...1000 MHz : 47 dBμV/m QP |
|
immunity to microbreaks |
10 ms
|
|
ambient air temperature for operation |
-10...55 °C for horizontal installation
-10...35 °C for vertical installation |
|
ambient air temperature for storage |
-25...70 °C
|
|
relative humidity |
10...95 % without condensation in operation
10...95 % without condensation in storage |
|
IP degree of protection |
IP20 with protective cover in place
|
|
pollution degree |
<= 2
|
|
operating altitude |
0...2000 m
|
|
storage altitude |
0...3000 m
|
|
vibration resistance |
3.5 mm (vibration frequency: 5...8.4 Hz) on symmetrical rail
1 gn (vibration frequency: 8.4...150 Hz) on symmetrical rail 3.5 mm (vibration frequency: 5...8.4 Hz) on panel mounting 1 gn (vibration frequency: 8.4...150 Hz) on panel mounting |
|
shock resistance |
147 m/s² (test wave duration:11 ms)
|
Schneider TM221C40U Controller M221-40IO TR.NPN | Advanced Programmable Logic Controller
- Brand: Schneider
- Product Code: TM221C40U
- Availability: 1000
Tags: Schneider TM221C40U, M221-40IO TR.NPN, PLC, Programmable Logic Controller, Industrial Automation, Digital I/O Controller, High-Performance PLC, Modbus PLC, Ethernet PLC, Automation Solutions, Industrial Control