Schneider TM221CE16R Controller M221 - 16 I/O Relay, Ethernet Enabled
Overview: Elevate your industrial automation solutions with the Schneider TM221CE16R Controller M221. This robust and versatile programmable logic controller (PLC) is engineered to meet the demanding needs of modern industrial applications. With its 16 relay I/O channels and integrated Ethernet connectivity, the TM221CE16R offers exceptional performance, flexibility, and connectivity, making it an ideal choice for complex control systems and automation projects.
Key Features:
16 Relay I/O Channels: The TM221CE16R is equipped with 16 high-quality relay outputs and 16 digital inputs, providing reliable and precise control for a wide range of industrial processes. Each relay is rated for 2A, ensuring robust performance and long-term durability.
Integrated Ethernet Communication: The built-in Ethernet port allows for seamless network integration, enabling efficient data exchange and remote access. This feature supports various communication protocols, including Modbus TCP, facilitating easy integration with other devices and systems.
Compact Design: With its space-saving design, the TM221CE16R is perfect for installations with limited panel space. Its compact form factor does not compromise its performance or functionality, making it suitable for a variety of applications.
Enhanced Programming and Debugging: The controller supports Schneider Electric's ecoStruxure™ Machine Expert software, which provides a user-friendly programming environment. This software simplifies the development process with advanced debugging and diagnostic tools, ensuring efficient programming and maintenance.
Scalability and Flexibility: Designed to adapt to evolving needs, the TM221CE16R offers scalability with support for expansion modules. This flexibility allows for future upgrades and the addition of more I/O points as your system requirements grow.
Robust Performance: The TM221CE16R is built to operate reliably in demanding industrial environments. It features a wide operating temperature range, high immunity to electrical noise, and robust protection against surges and spikes, ensuring stable performance even in challenging conditions.
Ease of Use: The controller includes intuitive status indicators and a user-friendly interface for easy monitoring and configuration. This simplifies setup and reduces installation time, allowing for quick deployment and efficient system management.
Applications: The Schneider TM221CE16R Controller M221 is suitable for a wide array of industrial applications, including but not limited to:
- Manufacturing automation
- Process control systems
- Building management systems
- Machine control and monitoring
- Remote automation and control
Specifications:
- Model: TM221CE16R
- I/O Configuration: 16 relay outputs, 16 digital inputs
- Communication Ports: 1 Ethernet port
- Programming Software: ecoStruxure™ Machine Expert
- Operating Temperature Range: [Specify range]
- Protection Rating: [Specify rating]
Why Choose Schneider TM221CE16R? The Schneider TM221CE16R Controller M221 combines advanced features, reliable performance, and ease of integration, making it a premier choice for professionals seeking a high-quality PLC solution. Whether you’re upgrading an existing system or designing a new automation project, the TM221CE16R delivers the performance and flexibility required to meet your needs.
Contact Us: For more information about the Schneider TM221CE16R Controller M221 or to request a quote, please contact our sales team
range of product |
Modicon M221
|
|
---|---|---|
product or component type |
Logic controller
|
|
[Us] rated supply voltage |
100...240 V AC
|
|
discrete input number |
9 discrete input conforming to IEC 61131-2 Type 1
|
|
analogue input number |
2 at input range: 0...10 V
|
|
discrete output type |
Relay normally open
|
|
discrete output number |
7 relay
|
|
discrete output voltage |
5...125 V DC
5...250 V AC |
|
discrete output current |
2 A
|
discrete I/O number |
16
|
|
---|---|---|
number of I/O expansion module |
<= 4 for transistor output
<= 4 for relay output |
|
supply voltage limits |
85...264 V
|
|
network frequency |
50/60 Hz
|
|
inrush current |
<= 40 A
|
|
power consumption in VA |
<= 49 VA at 100...240 V with max number of I/O expansion module
<= 33 VA at 100...240 V without I/O expansion module |
|
power supply output current |
0.325 A at 5 V for expansion bus
0.12 A at 24 V for expansion bus |
|
discrete input logic |
Sink or source (positive/negative)
|
|
discrete input voltage |
24 V
|
|
discrete input voltage type |
DC
|
|
analogue input resolution |
10 bits
|
|
LSB value |
10 mV
|
|
conversion time |
1 ms per channel + 1 controller cycle time for analog input
|
|
permitted overload on inputs |
+/- 30 V DC for analog input with 5 min maximum
+/- 13 V DC for analog input permanent |
|
voltage state 1 guaranteed |
>= 15 V for input
|
|
voltage state 0 guaranteed |
<= 5 V for input
|
|
discrete input current |
7 mA for discrete input
5 mA for fast input |
|
input impedance |
4.9 kOhm for fast input
3.4 kOhm for discrete input 100 kOhm for analog input |
|
response time |
10 ms turn-on operation for output
35 µs turn-off operation for input; I2...I5 terminal 10 ms turn-off operation for output 5 µs turn-on operation for fast input; I0, I1, I6, I7 terminal 35 µs turn-on operation for input; other terminals terminal 5 µs turn-off operation for fast input; I0, I1, I6, I7 terminal 100 µs turn-off operation for input; other terminals terminal |
|
configurable filtering time |
0 ms for input
12 ms for input 3 ms for input |
|
output voltage limits |
125 V DC
277 V AC |
|
current per output common |
6 A at COM 1 termnal
7 A at COM 0 termnal |
|
absolute accuracy error |
+/- 1 % of full scale for analog input
|
|
electrical durability |
Inductive AC-15, (cos phi = 0.35) 240 V / 120 VA : 100000 cycles
Resistive DC-12, 24 V / 48 W : 100000 cycles Resistive AC-12, 120 V / 240 VA : 100000 cycles Inductive AC-15, (cos phi = 0.35) 240 V / 36 VA : 300000 cycles Resistive AC-12, 120 V / 80 VA : 300000 cycles Inductive (L/R = 7 ms) DC-13, 24 V / 24 W : 100000 cycles Resistive DC-12, 24 V / 16 W : 300000 cycles Inductive (L/R = 7 ms) DC-13, 24 V / 7.2 W : 300000 cycles Inductive AC-14, (cos phi = 0.7) 240 V / 240 VA : 100000 cycles Inductive AC-15, (cos phi = 0.35) 120 V / 60 VA : 100000 cycles Inductive AC-14, (cos phi = 0.7) 240 V / 72 VA : 300000 cycles Inductive AC-15, (cos phi = 0.35) 120 V / 18 VA : 300000 cycles Resistive AC-12, 240 V / 480 VA : 100000 cycles Inductive AC-14, (cos phi = 0.7) 120 V / 120 VA : 100000 cycles Resistive AC-12, 240 V / 160 VA : 300000 cycles Inductive AC-14, (cos phi = 0.7) 120 V / 36 VA : 300000 cycles |
|
switching frequency |
20 switching operations/minute with maximum load
|
|
mechanical durability |
>= 20000000 cycles for relay output
|
|
minimum load |
1 mA at 5 V DC for relay output
|
|
protection type |
Without protection at 5 A
|
|
reset time |
1 s
|
|
memory capacity |
256 kB for user application and data RAM with 10000 instructions
256 kB for internal variables RAM |
|
data backed up |
256 kB built-in flash memory for backup of application and data
|
|
data storage equipment |
2 GB SD card optional
|
|
battery type |
BR2032 lithium non-rechargeable, battery life: 4 yr
|
|
backup time |
1 year at 25 °C by interruption of power supply
|
|
execution time for 1 KInstruction |
0.3 ms for event and periodic task
|
|
execution time per instruction |
0.2 µs Boolean
|
|
exct time for event task |
60 µs response time
|
|
maximum size of object areas |
8000 %MW memory words
512 %M memory bits 255 %C counters 512 %KW constant words 255 %TM timers |
|
realtime clock |
With
|
|
clock drift |
<= 30 s/month at 25 °C
|
|
regulation loop |
Adjustable PID regulator up to 14 simultaneous loops
|
|
counting input number |
4 fast input (HSC mode) (counting frequency: 100 kHz), counting
capacity: 32 bits
|
|
counter function |
Single phase
A/B Pulse/direction |
|
integrated connection type |
USB port with connector mini B USB 2.0
Ethernet with connector RJ45 Non isolated serial link "serial 1" with connector RJ45 and interface RS232/RS485 |
|
supply |
Serial serial link supply at 5 V 200 mA
|
|
transmission rate |
1.2...115.2 kbit/s (115.2 kbit/s by default) for bus length of
15 m - communication protocol: RS485
1.2...115.2 kbit/s (115.2 kbit/s by default) for bus length of 3 m - communication protocol: RS232 480 Mbit/s - communication protocol: USB |
|
communication port protocol |
USB port : USB protocol - SoMachine-Network
Non isolated serial link : Modbus protocol master/slave - RTU/ASCII or SoMachine-Network : Ethernet protocol |
|
port Ethernet |
10BASE-T/100BASE-TX 1 port with 100 m copper cable
|
|
communication service |
Modbus TCP client
Modbus TCP server DHCP client Modbus TCP slave device Ethernet/IP adapter |
|
local signalling |
1 LED green for SD card access (SD)
1 LED red for BAT 1 LED per channel green for I/O state 1 LED green for SL Ethernet network activity green for ACT Ethernet network link yellow for Link (Link Status) 1 LED red for module error (ERR) 1 LED green for PWR 1 LED green for RUN |
|
electrical connection |
Mini B USB 2.0 connector for a programming terminal
Terminal block, 3 terminal(s) for connecting the 24 V DC power supply Connector, 4 terminal(s) for analogue inputs Removable screw terminal block for inputs Removable screw terminal block for outputs |
|
cable distance between devices |
Shielded cable: 10 m for fast input
Unshielded cable: 30 m for output Unshielded cable: 30 m for digital input Unshielded cable: 1 m for analog input |
|
insulation |
2300 V AC between output and internal logic
Non-insulated between analogue inputs 500 V AC between input and internal logic Non-insulated between analogue input and internal logic 1500 V AC between supply and ground 500 V AC between sensor power supply and ground 500 V AC between input and ground 1500 V AC between output and ground 2300 V AC between supply and internal logic 500 V AC between sensor power supply and internal logic 500 V AC between Ethernet terminal and internal logic 2300 V AC between supply and sensor power supply |
|
marking |
CE
|
|
sensor power supply |
24 V DC at 250 mA supplied by the controller
|
|
mounting support |
Top hat type TH35-15 rail conforming to IEC 60715
Top hat type TH35-7.5 rail conforming to IEC 60715 Plate or panel with fixing kit |
|
height |
90 mm
|
|
depth |
70 mm
|
|
width |
95 mm
|
|
product weight |
0.346 kg
|
standards |
EN/IEC 61131-2
EN/IEC 60664-1 EN/IEC 61010-2-201 |
|
---|---|---|
product certifications |
cULus
CSA EAC LR DNV-GL RCM ABS IACS E10 |
|
environmental characteristic |
Ordinary and hazardous location
|
|
resistance to electrostatic discharge |
4 kV on contact conforming to EN/IEC 61000-4-2
8 kV in air conforming to EN/IEC 61000-4-2 |
|
resistance to electromagnetic fields |
10 V/m ( 80 MHz...1 GHz) conforming to EN/IEC 61000-4-3
3 V/m ( 1.4 GHz...2 GHz) conforming to EN/IEC 61000-4-3 1 V/m ( 2...2.7 GHz) conforming to EN/IEC 61000-4-3 |
|
resistance to magnetic fields |
30 A/m 50/60 Hz conforming to EN/IEC 61000-4-8
|
|
resistance to fast transients |
2 kV for power lines conforming to EN/IEC 61000-4-4
2 kV for relay output conforming to EN/IEC 61000-4-4 1 kV for Ethernet line conforming to EN/IEC 61000-4-4 1 kV for serial link conforming to EN/IEC 61000-4-4 1 kV for I/O conforming to EN/IEC 61000-4-4 |
|
surge withstand |
2 kV for power lines (AC) in common mode conforming to EN/IEC
61000-4-5
2 kV for relay output in common mode conforming to EN/IEC 61000-4-5 1 kV for I/O in common mode conforming to EN/IEC 61000-4-5 1 kV for shielded cable in common mode conforming to EN/IEC 61000-4-5 0.5 kV for power lines (DC) in differential mode conforming to EN/IEC 61000-4-5 1 kV for power lines (AC) in differential mode conforming to EN/IEC 61000-4-5 1 kV for relay output in differential mode conforming to EN/IEC 61000-4-5 0.5 kV for power lines (DC) in common mode conforming to EN/IEC 61000-4-5 |
|
resistance to conducted disturbances |
10 Vrms (0.15...80 MHz) conforming to EN/IEC 61000-4-6
3 Vrms (0.1...80 MHz) conforming to Marine specification (LR, ABS, DNV, GL) 10 Vrms (spot frequency (2, 3, 4, 6.2, 8.2, 12.6, 16.5, 18.8, 22, 25 MHz)) conforming to Marine specification (LR, ABS, DNV, GL) |
|
electromagnetic emission |
Conducted emissions conforming to EN/IEC 55011 power lines (AC),
0.15...0.5 MHz : 79 dBμV/m QP/66 dBμV/m AV
Conducted emissions conforming to EN/IEC 55011 power lines (AC), 0.5...300 MHz : 73 dBμV/m QP/60 dBμV/m AV Conducted emissions conforming to EN/IEC 55011 power lines, 10...150 kHz : 120...69 dBµV/m QP Conducted emissions conforming to EN/IEC 55011 power lines, 1.5...30 MHz : 63 dBμV/m QP Radiated emissions conforming to EN/IEC 55011 class A 10 m, 30...230 MHz : 40 dBμV/m QP Conducted emissions conforming to EN/IEC 55011 power lines, 150...1500 kHz : 79...63 dBμV/m QP Radiated emissions conforming to EN/IEC 55011 class A 10 m, 200...1000 MHz : 47 dBμV/m QP |
|
immunity to microbreaks |
10 ms
|
|
ambient air temperature for operation |
-10...55 °C for horizontal installation
-10...35 °C for vertical installation |
|
ambient air temperature for storage |
-25...70 °C
|
|
relative humidity |
10...95 % without condensation in operation
10...95 % without condensation in storage |
|
IP degree of protection |
IP20 with protective cover in place
|
|
pollution degree |
<= 2
|
|
operating altitude |
0...2000 m
|
|
storage altitude |
0...3000 m
|
< |
Schneider TM221CE16R Controller M221 - 16 I/O Relay with Ethernet
- Brand: Schneider
- Product Code: TM221CE16R
- Availability: 1000
Tags: Schneider TM221CE16R, Controller M221, 16 I/O Relay, Ethernet PLC, Industrial Automation, Programmable Logic Controller, PLC with Ethernet, Schneider Electric, Automation Control, Relay I/O PLC