• Schneider TM221CE16R Controller M221 - 16 I/O Relay with Ethernet

Schneider TM221CE16R Controller M221 - 16 I/O Relay, Ethernet Enabled

Overview: Elevate your industrial automation solutions with the Schneider TM221CE16R Controller M221. This robust and versatile programmable logic controller (PLC) is engineered to meet the demanding needs of modern industrial applications. With its 16 relay I/O channels and integrated Ethernet connectivity, the TM221CE16R offers exceptional performance, flexibility, and connectivity, making it an ideal choice for complex control systems and automation projects.

Key Features:

  • 16 Relay I/O Channels: The TM221CE16R is equipped with 16 high-quality relay outputs and 16 digital inputs, providing reliable and precise control for a wide range of industrial processes. Each relay is rated for 2A, ensuring robust performance and long-term durability.

  • Integrated Ethernet Communication: The built-in Ethernet port allows for seamless network integration, enabling efficient data exchange and remote access. This feature supports various communication protocols, including Modbus TCP, facilitating easy integration with other devices and systems.

  • Compact Design: With its space-saving design, the TM221CE16R is perfect for installations with limited panel space. Its compact form factor does not compromise its performance or functionality, making it suitable for a variety of applications.

  • Enhanced Programming and Debugging: The controller supports Schneider Electric's ecoStruxure™ Machine Expert software, which provides a user-friendly programming environment. This software simplifies the development process with advanced debugging and diagnostic tools, ensuring efficient programming and maintenance.

  • Scalability and Flexibility: Designed to adapt to evolving needs, the TM221CE16R offers scalability with support for expansion modules. This flexibility allows for future upgrades and the addition of more I/O points as your system requirements grow.

  • Robust Performance: The TM221CE16R is built to operate reliably in demanding industrial environments. It features a wide operating temperature range, high immunity to electrical noise, and robust protection against surges and spikes, ensuring stable performance even in challenging conditions.

  • Ease of Use: The controller includes intuitive status indicators and a user-friendly interface for easy monitoring and configuration. This simplifies setup and reduces installation time, allowing for quick deployment and efficient system management.

Applications: The Schneider TM221CE16R Controller M221 is suitable for a wide array of industrial applications, including but not limited to:

  • Manufacturing automation
  • Process control systems
  • Building management systems
  • Machine control and monitoring
  • Remote automation and control

Specifications:

  • Model: TM221CE16R
  • I/O Configuration: 16 relay outputs, 16 digital inputs
  • Communication Ports: 1 Ethernet port
  • Programming Software: ecoStruxure™ Machine Expert
  • Operating Temperature Range: [Specify range]
  • Protection Rating: [Specify rating]

Why Choose Schneider TM221CE16R? The Schneider TM221CE16R Controller M221 combines advanced features, reliable performance, and ease of integration, making it a premier choice for professionals seeking a high-quality PLC solution. Whether you’re upgrading an existing system or designing a new automation project, the TM221CE16R delivers the performance and flexibility required to meet your needs.

Contact Us: For more information about the Schneider TM221CE16R Controller M221 or to request a quote, please contact our sales team

Main
range of product
Modicon M221
product or component type
Logic controller
[Us] rated supply voltage
100...240 V AC
discrete input number
9 discrete input conforming to IEC 61131-2 Type 1
analogue input number
2 at input range: 0...10 V
discrete output type
Relay normally open
discrete output number
7 relay
discrete output voltage
5...125 V DC
5...250 V AC
discrete output current
2 A
Complementary
discrete I/O number
16
number of I/O expansion module
<= 4 for transistor output
<= 4 for relay output
supply voltage limits
85...264 V
network frequency
50/60 Hz
inrush current
<= 40 A
power consumption in VA
<= 49 VA at 100...240 V with max number of I/O expansion module
<= 33 VA at 100...240 V without I/O expansion module
power supply output current
0.325 A at 5 V for expansion bus
0.12 A at 24 V for expansion bus
discrete input logic
Sink or source (positive/negative)
discrete input voltage
24 V
discrete input voltage type
DC
analogue input resolution
10 bits
LSB value
10 mV
conversion time
1 ms per channel + 1 controller cycle time for analog input
permitted overload on inputs
+/- 30 V DC for analog input with 5 min maximum
+/- 13 V DC for analog input permanent
voltage state 1 guaranteed
>= 15 V for input
voltage state 0 guaranteed
<= 5 V for input
discrete input current
7 mA for discrete input
5 mA for fast input
input impedance
4.9 kOhm for fast input
3.4 kOhm for discrete input
100 kOhm for analog input
response time
10 ms turn-on operation for output
35 µs turn-off operation for input; I2...I5 terminal
10 ms turn-off operation for output
5 µs turn-on operation for fast input; I0, I1, I6, I7 terminal
35 µs turn-on operation for input; other terminals terminal
5 µs turn-off operation for fast input; I0, I1, I6, I7 terminal
100 µs turn-off operation for input; other terminals terminal
configurable filtering time
0 ms for input
12 ms for input
3 ms for input
output voltage limits
125 V DC
277 V AC
current per output common
6 A at COM 1 termnal
7 A at COM 0 termnal
absolute accuracy error
+/- 1 % of full scale for analog input
electrical durability
Inductive AC-15, (cos phi = 0.35) 240 V / 120 VA : 100000 cycles
Resistive DC-12, 24 V / 48 W : 100000 cycles
Resistive AC-12, 120 V / 240 VA : 100000 cycles
Inductive AC-15, (cos phi = 0.35) 240 V / 36 VA : 300000 cycles
Resistive AC-12, 120 V / 80 VA : 300000 cycles
Inductive (L/R = 7 ms) DC-13, 24 V / 24 W : 100000 cycles
Resistive DC-12, 24 V / 16 W : 300000 cycles
Inductive (L/R = 7 ms) DC-13, 24 V / 7.2 W : 300000 cycles
Inductive AC-14, (cos phi = 0.7) 240 V / 240 VA : 100000 cycles
Inductive AC-15, (cos phi = 0.35) 120 V / 60 VA : 100000 cycles
Inductive AC-14, (cos phi = 0.7) 240 V / 72 VA : 300000 cycles
Inductive AC-15, (cos phi = 0.35) 120 V / 18 VA : 300000 cycles
Resistive AC-12, 240 V / 480 VA : 100000 cycles
Inductive AC-14, (cos phi = 0.7) 120 V / 120 VA : 100000 cycles
Resistive AC-12, 240 V / 160 VA : 300000 cycles
Inductive AC-14, (cos phi = 0.7) 120 V / 36 VA : 300000 cycles
switching frequency
20 switching operations/minute with maximum load
mechanical durability
>= 20000000 cycles for relay output
minimum load
1 mA at 5 V DC for relay output
protection type
Without protection at 5 A
reset time
1 s
memory capacity
256 kB for user application and data RAM with 10000 instructions
256 kB for internal variables RAM
data backed up
256 kB built-in flash memory for backup of application and data
data storage equipment
2 GB SD card optional
battery type
BR2032 lithium non-rechargeable, battery life: 4 yr
backup time
1 year at 25 °C by interruption of power supply
execution time for 1 KInstruction
0.3 ms for event and periodic task
execution time per instruction
0.2 µs Boolean
exct time for event task
60 µs response time
maximum size of object areas
8000 %MW memory words
512 %M memory bits
255 %C counters
512 %KW constant words
255 %TM timers
realtime clock
With
clock drift
<= 30 s/month at 25 °C
regulation loop
Adjustable PID regulator up to 14 simultaneous loops
counting input number
4 fast input (HSC mode) (counting frequency: 100 kHz), counting capacity: 32 bits
counter function
Single phase
A/B
Pulse/direction
integrated connection type
USB port with connector mini B USB 2.0
Ethernet with connector RJ45
Non isolated serial link "serial 1" with connector RJ45 and interface RS232/RS485
supply
Serial serial link supply at 5 V 200 mA
transmission rate
1.2...115.2 kbit/s (115.2 kbit/s by default) for bus length of 15 m - communication protocol: RS485
1.2...115.2 kbit/s (115.2 kbit/s by default) for bus length of 3 m - communication protocol: RS232
480 Mbit/s - communication protocol: USB
communication port protocol
USB port : USB protocol - SoMachine-Network
Non isolated serial link : Modbus protocol master/slave - RTU/ASCII or SoMachine-Network
: Ethernet protocol
port Ethernet
10BASE-T/100BASE-TX 1 port with 100 m copper cable
communication service
Modbus TCP client
Modbus TCP server
DHCP client
Modbus TCP slave device
Ethernet/IP adapter
local signalling
1 LED green for SD card access (SD)
1 LED red for BAT
1 LED per channel green for I/O state
1 LED green for SL
Ethernet network activity green for ACT
Ethernet network link yellow for Link (Link Status)
1 LED red for module error (ERR)
1 LED green for PWR
1 LED green for RUN
electrical connection
Mini B USB 2.0 connector for a programming terminal
Terminal block, 3 terminal(s) for connecting the 24 V DC power supply
Connector, 4 terminal(s) for analogue inputs
Removable screw terminal block for inputs
Removable screw terminal block for outputs
cable distance between devices
Shielded cable: 10 m for fast input
Unshielded cable: 30 m for output
Unshielded cable: 30 m for digital input
Unshielded cable: 1 m for analog input
insulation
2300 V AC between output and internal logic
Non-insulated between analogue inputs
500 V AC between input and internal logic
Non-insulated between analogue input and internal logic
1500 V AC between supply and ground
500 V AC between sensor power supply and ground
500 V AC between input and ground
1500 V AC between output and ground
2300 V AC between supply and internal logic
500 V AC between sensor power supply and internal logic
500 V AC between Ethernet terminal and internal logic
2300 V AC between supply and sensor power supply
marking
CE
sensor power supply
24 V DC at 250 mA supplied by the controller
mounting support
Top hat type TH35-15 rail conforming to IEC 60715
Top hat type TH35-7.5 rail conforming to IEC 60715
Plate or panel with fixing kit
height
90 mm
depth
70 mm
width
95 mm
product weight
0.346 kg

Environment
standards
EN/IEC 61131-2
EN/IEC 60664-1
EN/IEC 61010-2-201
product certifications
cULus
CSA
EAC
LR
DNV-GL
RCM
ABS
IACS E10
environmental characteristic
Ordinary and hazardous location
resistance to electrostatic discharge
4 kV on contact conforming to EN/IEC 61000-4-2
8 kV in air conforming to EN/IEC 61000-4-2
resistance to electromagnetic fields
10 V/m ( 80 MHz...1 GHz) conforming to EN/IEC 61000-4-3
3 V/m ( 1.4 GHz...2 GHz) conforming to EN/IEC 61000-4-3
1 V/m ( 2...2.7 GHz) conforming to EN/IEC 61000-4-3
resistance to magnetic fields
30 A/m 50/60 Hz conforming to EN/IEC 61000-4-8
resistance to fast transients
2 kV for power lines conforming to EN/IEC 61000-4-4
2 kV for relay output conforming to EN/IEC 61000-4-4
1 kV for Ethernet line conforming to EN/IEC 61000-4-4
1 kV for serial link conforming to EN/IEC 61000-4-4
1 kV for I/O conforming to EN/IEC 61000-4-4
surge withstand
2 kV for power lines (AC) in common mode conforming to EN/IEC 61000-4-5
2 kV for relay output in common mode conforming to EN/IEC 61000-4-5
1 kV for I/O in common mode conforming to EN/IEC 61000-4-5
1 kV for shielded cable in common mode conforming to EN/IEC 61000-4-5
0.5 kV for power lines (DC) in differential mode conforming to EN/IEC 61000-4-5
1 kV for power lines (AC) in differential mode conforming to EN/IEC 61000-4-5
1 kV for relay output in differential mode conforming to EN/IEC 61000-4-5
0.5 kV for power lines (DC) in common mode conforming to EN/IEC 61000-4-5
resistance to conducted disturbances
10 Vrms (0.15...80 MHz) conforming to EN/IEC 61000-4-6
3 Vrms (0.1...80 MHz) conforming to Marine specification (LR, ABS, DNV, GL)
10 Vrms (spot frequency (2, 3, 4, 6.2, 8.2, 12.6, 16.5, 18.8, 22, 25 MHz)) conforming to Marine specification (LR, ABS, DNV, GL)
electromagnetic emission
Conducted emissions conforming to EN/IEC 55011 power lines (AC), 0.15...0.5 MHz : 79 dBμV/m QP/66 dBμV/m AV
Conducted emissions conforming to EN/IEC 55011 power lines (AC), 0.5...300 MHz : 73 dBμV/m QP/60 dBμV/m AV
Conducted emissions conforming to EN/IEC 55011 power lines, 10...150 kHz : 120...69 dBµV/m QP
Conducted emissions conforming to EN/IEC 55011 power lines, 1.5...30 MHz : 63 dBμV/m QP
Radiated emissions conforming to EN/IEC 55011 class A 10 m, 30...230 MHz : 40 dBμV/m QP
Conducted emissions conforming to EN/IEC 55011 power lines, 150...1500 kHz : 79...63 dBμV/m QP
Radiated emissions conforming to EN/IEC 55011 class A 10 m, 200...1000 MHz : 47 dBμV/m QP
immunity to microbreaks
10 ms
ambient air temperature for operation
-10...55 °C for horizontal installation
-10...35 °C for vertical installation
ambient air temperature for storage
-25...70 °C
relative humidity
10...95 % without condensation in operation
10...95 % without condensation in storage
IP degree of protection
IP20 with protective cover in place
pollution degree
<= 2
operating altitude
0...2000 m
storage altitude
0...3000 m
<

Schneider TM221CE16R Controller M221 - 16 I/O Relay with Ethernet

  • Brand: Schneider
  • Product Code: TM221CE16R
  • Availability: 1000

Tags: Schneider TM221CE16R, Controller M221, 16 I/O Relay, Ethernet PLC, Industrial Automation, Programmable Logic Controller, PLC with Ethernet, Schneider Electric, Automation Control, Relay I/O PLC