Schneider TM221CE40U M221-40IO Controller - NPN Transistor Outputs, Ethernet Connectivity
  • Brand: Schneider
  • Product Code: TM221CE40U
1000 |

Ex Tax: $0.00
Loading...

Description

Schneider TM221CE40U Controller M221-40IO TR.NPN Ethernet

Overview:

The Schneider TM221CE40U Controller M221-40IO TR.NPN Ethernet is an advanced, versatile programmable logic controller (PLC) designed to enhance the efficiency and reliability of automation systems. This high-performance PLC is part of Schneider Electric’s renowned M221 series, offering exceptional functionality for a wide range of industrial applications.

Key Features:

  • Compact and Robust Design: The TM221CE40U features a space-saving design with a robust build quality, making it ideal for integration into both small and large automation systems. Its compact footprint ensures easy installation in confined spaces while maintaining durability in demanding environments.

  • I/O Configuration: Equipped with 40 input/output (I/O) points, including 24 digital inputs, 16 digital outputs, and 4 analog inputs, the TM221CE40U provides flexible and comprehensive I/O capabilities to accommodate diverse application needs. This configuration supports various input and output types, including NPN (Negative-Positive-Negative) transistor outputs, ensuring compatibility with a wide range of field devices.

  • Ethernet Connectivity: The built-in Ethernet port facilitates seamless integration into networked environments, enabling efficient communication and control. With Ethernet connectivity, users can take advantage of remote monitoring, diagnostics, and program updates, enhancing system flexibility and reducing maintenance time.

  • Programming and Software Support: The TM221CE40U is compatible with Schneider Electric’s EcoStruxure™ Machine Expert software, a powerful programming environment that simplifies configuration and programming tasks. This software supports multiple programming languages, including ladder logic, function block diagram, and structured text, ensuring ease of use and adaptability for different automation requirements.

  • Advanced Functionality: The controller offers advanced features such as high-speed counters, pulse-width modulation (PWM) outputs, and a real-time clock, making it suitable for complex and time-sensitive applications. Its extensive range of functions and capabilities enables precise control and monitoring of various processes.

  • Scalability and Integration: The TM221CE40U is designed to integrate seamlessly with other Schneider Electric automation components, including HMIs, drives, and sensors. Its modular design allows for easy expansion and scalability, making it a versatile solution for evolving automation needs.

  • High Reliability and Performance: Built to meet industrial standards, the TM221CE40U ensures reliable operation and high performance even in harsh conditions. Its robust design and advanced features contribute to improved system uptime and operational efficiency.

Applications:

The Schneider TM221CE40U Controller M221-40IO TR.NPN Ethernet is ideal for a variety of industrial automation applications, including:

  • Manufacturing and production lines
  • Process control systems
  • Building automation
  • Machine control and monitoring
  • Energy management systems

Specifications:

  • Model: TM221CE40U
  • I/O Points: 40 (24 digital inputs, 16 digital outputs, 4 analog inputs)
  • Output Type: NPN Transistor
  • Connectivity: Ethernet
  • Software: EcoStruxure™ Machine Expert
  • Dimensions: [Insert dimensions here]
  • Operating Temperature Range: [Insert temperature range here]
  • Power Supply: [Insert power supply details here]

Conclusion:

The Schneider TM221CE40U Controller M221-40IO TR.NPN Ethernet is a powerful and versatile PLC solution designed to meet the demands of modern industrial automation. With its comprehensive I/O capabilities, advanced features, and reliable performance, it is an excellent choice for enhancing the efficiency and functionality of your automation systems.

For more information or to request a quote, please contact us

Main
range of product
Modicon M221
product or component type
Logic controller
[Us] rated supply voltage
24 V DC
discrete input number
24 discrete input conforming to IEC 61131-2 Type 1 including 4 fast input
analogue input number
2 at input range: 0...10 V
discrete output type
Transistor
discrete output number
16 transistor including 4 fast output
discrete output voltage
24 V DC
discrete output current
0.5 A
Complementary
discrete I/O number
40
number of I/O expansion module
<= 7 for relay output
supply voltage limits
20.4...28.8 V
inrush current
<= 35 A
power consumption in W
<= 17 W at 24 V with max number of I/O expansion module
<= 4.9 W at 24 V without I/O expansion module
power supply output current
0.52 A at 5 V for expansion bus
0.3 A at 24 V for expansion bus
discrete input logic
Sink or source (positive/negative)
discrete input voltage
24 V
discrete input voltage type
DC
analogue input resolution
10 bits
LSB value
10 mV
conversion time
1 ms per channel + 1 controller cycle time for analog input
permitted overload on inputs
+/- 30 V DC for analog input with 5 min maximum
+/- 13 V DC for analog input permanent
voltage state 1 guaranteed
>= 15 V for input
voltage state 0 guaranteed
<= 5 V for input
discrete input current
7 mA for discrete input
5 mA for fast input
input impedance
4.9 kOhm for fast input
3.4 kOhm for discrete input
100 kOhm for analog input
response time
35 µs turn-off operation for input; I2...I5 terminal
5 µs turn-on operation for fast input; I0, I1, I6, I7 terminal
35 µs turn-on operation for input; other terminals terminal
5 µs turn-off operation for fast input; I0, I1, I6, I7 terminal
100 µs turn-off operation for input; other terminals terminal
300 µs turn-on, turn-off operation for output; other terminals terminal
5 µs turn-on, turn-off operation for output; Q0...Q3 terminal
configurable filtering time
0 ms for input
12 ms for input
3 ms for input
discrete output logic
Negative logic (sink)
current per output common
4 A
output frequency
0.1 kHz for output at Q4...Q15 termnal
100 kHz for fast output (PWM/PLS mode) at Q0...Q3 termnal
absolute accuracy error
+/- 1 % of full scale for analog input
leakage current
0.1 mA for transistor output
voltage drop
<= 1 V
mechanical durability
>= 20000000 cycles for transistor output
tungsten load
<= 12 W for output and fast output
protection type
Without protection
memory capacity
256 kB for user application and data RAM with 10000 instructions
256 kB for internal variables RAM
data backed up
256 kB built-in flash memory for backup of application and data
data storage equipment
2 GB SD card optional
battery type
BR2032 lithium non-rechargeable, battery life: 4 yr
backup time
1 year at 25 °C by interruption of power supply
execution time for 1 KInstruction
0.3 ms for event and periodic task
execution time per instruction
0.2 µs Boolean
exct time for event task
60 µs response time
maximum size of object areas
512 %M memory bits
255 %C counters
255 %TM timers
512 %KW constant words
8000 %MW memory words
realtime clock
With
clock drift
<= 30 s/month at 25 °C
regulation loop
Adjustable PID regulator up to 14 simultaneous loops
positioning functions
Position PTO 4 axe(s) pulse/direction mode (100 kHz)
Position PTO 2 axe(s) CW/CCW mode (100 kHz)
function available
PWM
Frequency generator
PLS
counting input number
4 fast input (HSC mode) (counting frequency: 100 kHz), counting capacity: 32 bits
counter function
Single phase
A/B
Pulse/direction
integrated connection type
USB port with connector mini B USB 2.0
Ethernet with connector RJ45
Non isolated serial link "serial 1" with connector RJ45 and interface RS232/RS485
supply
Serial serial link supply at 5 V 200 mA
transmission rate
1.2...115.2 kbit/s (115.2 kbit/s by default) for bus length of 15 m - communication protocol: RS485
1.2...115.2 kbit/s (115.2 kbit/s by default) for bus length of 3 m - communication protocol: RS232
480 Mbit/s - communication protocol: USB
communication port protocol
USB port : USB protocol - SoMachine-Network
Non isolated serial link : Modbus protocol master/slave - RTU/ASCII or SoMachine-Network
: Ethernet protocol
port Ethernet
10BASE-T/100BASE-TX 1 port with 100 m copper cable
communication service
DHCP client
Modbus TCP client
Ethernet/IP adapter
Modbus TCP server
Modbus TCP slave device
local signalling
1 LED green for SD card access (SD)
1 LED red for BAT
1 LED per channel green for I/O state
1 LED green for SL
Ethernet network activity green for ACT
Ethernet network link yellow for Link (Link Status)
1 LED red for module error (ERR)
1 LED green for PWR
1 LED green for RUN
electrical connection
Mini B USB 2.0 connector for a programming terminal
Terminal block, 3 terminal(s) for connecting the 24 V DC power supply
Connector, 4 terminal(s) for analogue inputs
Removable screw terminal block for inputs
Removable screw terminal block for outputs
cable distance between devices
Shielded cable: 10 m for fast input
Unshielded cable: 30 m for output
Unshielded cable: 30 m for digital input
Unshielded cable: 1 m for analog input
Shielded cable: 3 m for fast output
insulation
500 V AC between fast input and internal logic
Non-insulated between inputs
Non-insulated between analogue inputs
500 V AC between output and internal logic
500 V AC between input and internal logic
Non-insulated between analogue input and internal logic
marking
CE
mounting support
Top hat type TH35-15 rail conforming to IEC 60715
Top hat type TH35-7.5 rail conforming to IEC 60715
Plate or panel with fixing kit
height
90 mm
depth
70 mm
width
160 mm
product weight
0.78 kg

Environment
standards
EN/IEC 61010-2-201
EN/IEC 61131-2
EN/IEC 60664-1
product certifications
DNV-GL
CSA
IACS E10
RCM
cULus
EAC
LR
ABS
environmental characteristic
Ordinary and hazardous location
resistance to electrostatic discharge
4 kV on contact conforming to EN/IEC 61000-4-2
8 kV in air conforming to EN/IEC 61000-4-2
resistance to electromagnetic fields
10 V/m ( 80 MHz...1 GHz) conforming to EN/IEC 61000-4-3
3 V/m ( 1.4 GHz...2 GHz) conforming to EN/IEC 61000-4-3
1 V/m ( 2 GHz...3 GHz) conforming to EN/IEC 61000-4-3
resistance to magnetic fields
30 A/m 50/60 Hz conforming to EN/IEC 61000-4-8
resistance to fast transients
2 kV for power lines conforming to EN/IEC 61000-4-4
2 kV for relay output conforming to EN/IEC 61000-4-4
1 kV for Ethernet line conforming to EN/IEC 61000-4-4
1 kV for serial link conforming to EN/IEC 61000-4-4
1 kV for I/O conforming to EN/IEC 61000-4-4
surge withstand
2 kV for power lines (AC) in common mode conforming to EN/IEC 61000-4-5
2 kV for relay output in common mode conforming to EN/IEC 61000-4-5
1 kV for I/O in common mode conforming to EN/IEC 61000-4-5
1 kV for shielded cable in common mode conforming to EN/IEC 61000-4-5
0.5 kV for power lines (DC) in differential mode conforming to EN/IEC 61000-4-5
1 kV for power lines (AC) in differential mode conforming to EN/IEC 61000-4-5
1 kV for relay output in differential mode conforming to EN/IEC 61000-4-5
0.5 kV for power lines (DC) in common mode conforming to EN/IEC 61000-4-5
resistance to conducted disturbances
10 Vrms (0.15...80 MHz) conforming to EN/IEC 61000-4-6
3 Vrms (0.1...80 MHz) conforming to Marine specification (LR, ABS, DNV, GL)
10 Vrms (spot frequency (2, 3, 4, 6.2, 8.2, 12.6, 16.5, 18.8, 22, 25 MHz)) conforming to Marine specification (LR, ABS, DNV, GL)
electromagnetic emission
Conducted emissions conforming to EN/IEC 55011 power lines (AC), 0.15...0.5 MHz : 79 dBμV/m QP/66 dBμV/m AV
Conducted emissions conforming to EN/IEC 55011 power lines (AC), 0.5...300 MHz : 73 dBμV/m QP/60 dBμV/m AV
Conducted emissions conforming to EN/IEC 55011 power lines, 10...150 kHz : 120...69 dBµV/m QP
Conducted emissions conforming to EN/IEC 55011 power lines, 1.5...30 MHz : 63 dBμV/m QP
Radiated emissions conforming to EN/IEC 55011 class A 10 m, 30...230 MHz : 40 dBμV/m QP
Conducted emissions conforming to EN/IEC 55011 power lines, 150...1500 kHz : 79...63 dBμV/m QP
Radiated emissions conforming to EN/IEC 55011 class A 10 m, 200...1000 MHz : 47 dBμV/m QP
immunity to microbreaks
10 ms
ambient air temperature for operation
-10...55 °C for horizontal installation
-10...35 °C for vertical installation
ambient air temperature for storage
-25...70 °C
relative humidity
10...95 % without condensation in operation
10...95 % without condensation in storage
IP degree of protection
IP20 with protective cover in place
pollution degree
<= 2
operating altitude
0...2000 m
storage altitude
0...3000 m
vibration resistance
3.5 mm (vibration frequency: 5...8.4 Hz) on symmetrical rail
1 gn (vibration frequency: 8.4...150 Hz) on symmetrical rail
3.5 mm (vibration frequency: 5...8.4 Hz) on panel mounting
1 gn (vibration frequency: 8.4...150 Hz) on panel mounting
shock resistance