Schneider TM241C40R Controller M241 - 40 I/O Relay Unit
Overview: Unlock the full potential of your automation projects with the Schneider TM241C40R Controller M241. This advanced programmable logic controller (PLC) is engineered to deliver high performance and reliability for complex control and monitoring applications. Featuring 40 I/O relay channels, the TM241C40R offers unparalleled flexibility and scalability to meet diverse industrial needs.
Key Features:
High-Density I/O Configuration: The TM241C40R is equipped with 40 integrated relay I/O points, providing robust and versatile input and output capabilities. This high-density configuration allows for efficient management of numerous control and monitoring functions within a compact unit.
Enhanced Processing Power: Powered by Schneider Electric’s state-of-the-art processing technology, the M241 controller ensures swift and accurate execution of complex control algorithms. Its advanced processing capabilities support high-speed operations and facilitate the seamless integration of multiple automation tasks.
Versatile Communication Options: The TM241C40R offers multiple communication interfaces, including Ethernet, Modbus, and CANopen. These options enable seamless connectivity with various devices and networks, enhancing system interoperability and data exchange.
User-Friendly Programming: Schneider Electric’s ecoStruxure™ Machine Expert programming software simplifies the development and deployment of control programs. With intuitive graphical tools and a comprehensive library of function blocks, users can quickly create, test, and optimize their automation solutions.
Robust Build Quality: Designed to withstand challenging industrial environments, the TM241C40R features a rugged construction with high-quality components. Its durability ensures reliable operation even in harsh conditions, reducing maintenance requirements and extending the lifespan of the controller.
Scalable and Flexible: The M241 series is designed for scalability, allowing for easy expansion and adaptation to evolving automation needs. The modular design supports a wide range of I/O modules and accessories, enabling customization to suit specific application requirements.
Technical Specifications:
- I/O Configuration: 40 Relay I/O
- Communication Ports: Ethernet, Modbus, CANopen
- Programming Software: ecoStruxure™ Machine Expert
- Operating Temperature Range: -10°C to 55°C
- Power Supply: 24V DC
- Dimensions (HxWxD): [Insert Dimensions]
- Weight: [Insert Weight]
Applications:
The Schneider TM241C40R Controller M241 is ideal for a variety of industrial automation applications, including:
- Manufacturing process control
- Building automation
- Energy management systems
- Machine control and monitoring
Why Choose Schneider TM241C40R?
Schneider Electric’s TM241C40R combines advanced functionality with unparalleled reliability, making it the preferred choice for industrial professionals seeking a high-performance PLC solution. Its comprehensive feature set, coupled with Schneider Electric’s industry-leading support and service, ensures that your automation projects are executed with precision and efficiency.
Get Started Today:
Enhance your automation capabilities with the Schneider TM241C40R Controller M241. Contact us to learn more about how this powerful PLC can drive your projects forward and explore the full range of Schneider Electric solutions.
SEO Keywords: Schneider TM241C40R Controller, M241 40 I/O Relay, Schneider Electric PLC, programmable logic controller, industrial automation controller, ecoStruxure Machine Expert, high-performance PLC, versatile I/O controller, reliable PLC solutions.
range of product |
Modicon M241
|
|
---|---|---|
product or component type |
Logic controller
|
|
[Us] rated supply voltage |
100...240 V AC
|
|
discrete input number |
24 discrete input including 8 fast input conforming to IEC
61131-2 Type 1
|
|
discrete output type |
Transistor
Relay |
|
discrete output number |
12 relay
4 transistor including 4 fast output |
|
discrete output voltage |
24 V DC for transistor output
5...125 V DC for relay output 5...250 V AC for relay output |
|
discrete output current |
0.1 A with TR0...TR3 terminal(s) for fast output (PTO mode)
2 A with Q4...Q15 terminal(s) for relay output 0.5 A with TR0...TR3 terminal(s) for transistor output |
discrete I/O number |
40
|
|
---|---|---|
number of I/O expansion module |
7 (local I/O architecture)
14 (remote I/O architecture) |
|
supply voltage limits |
85...264 V
|
|
network frequency |
50/60 Hz
|
|
discrete input logic |
Sink or source
|
|
discrete input voltage |
24 V
|
|
discrete input voltage type |
DC
|
|
voltage state 1 guaranteed |
>= 15 V for input
|
|
voltage state 0 guaranteed |
<= 5 V for input
|
|
discrete input current |
7 mA for input
|
|
input impedance |
4.7 kOhm for input
|
|
response time |
50 µs turn-on operation with I0...I15 terminal(s) for input
|
|
configurable filtering time |
1 µs for fast input
|
|
discrete output logic |
Positive logic (source)
|
|
output voltage limits |
125 V DC relay output
30 V DC transistor output 277 V AC relay output |
|
output frequency |
<= 1 kHz for transistor output
<= 20 kHz for fast output (PWM mode) <= 100 kHz for fast output (PLS mode) |
|
accuracy |
+/- 0.1 % at 0.02...0.1 kHz for fast output
|
|
protection type |
Short-circuit protection for transistor output
Short-circuit and overload protection with automatic reset for transistor output Reverse polarity protection for transistor output Without protection for relay output |
|
reset time |
10 ms automatic reset output
12 s automatic reset fast output |
|
memory capacity |
8 MB for program
64 MB for system memory RAM |
|
data backed up |
128 MB built-in flash memory for backup of user programs
|
|
data storage equipment |
<= 16 GB SD card optional
|
|
battery type |
BR2032 lithium non-rechargeable, battery life: 4 yr
|
|
backup time |
2 years at 25 °C
|
|
execution time for 1 KInstruction |
0.3 ms for event and periodic task
0.7 ms for other instruction |
|
application structure |
4 cyclic master tasks
8 external event tasks 8 event tasks 3 cyclic master tasks + 1 freewheeling task |
|
realtime clock |
With
|
|
clock drift |
<= 60 s/month at 25 °C
|
|
positioning functions |
PTO function 4 channel(s) (positioning frequency: 100 kHz)
|
|
counting input number |
4 fast input (HSC mode) at 200 kHz
14 standard input at 1 kHz |
|
control signal type |
A/B signal at 100 kHz for fast input (HSC mode)
Pulse/direction signal at 200 kHz for fast input (HSC mode) Single phase signal at 200 kHz for fast input (HSC mode) |
|
integrated connection type |
USB port with connector mini B USB 2.0
Non isolated serial link "serial 1" with connector RJ45 and interface RS232/RS485 Non isolated serial link "serial 2" with connector removable screw terminal block and interface RS485 |
|
supply |
Serial link supply "serial 1" at 5 V, <= 200 mA
|
|
transmission rate |
1.2...115.2 kbit/s (115.2 kbit/s by default) for bus length of
15 m - communication protocol: RS485
1.2...115.2 kbit/s (115.2 kbit/s by default) for bus length of 3 m - communication protocol: RS232 480 Mbit/s for bus length of 3 m - communication protocol: USB |
|
communication port protocol |
Modbus non isolated serial link with master/slave method
|
|
local signalling |
1 LED green for SD card access (SD)
1 LED red for BAT 1 LED green for SL1 1 LED green for SL2 1 LED per channel green for I/O state 1 LED red for I/O error (I/O) 1 LED red for bus fault on TM4 (TM4) 1 LED red for module error (ERR) 1 LED green for PWR 1 LED green for RUN |
|
electrical connection |
Removable screw terminal block for inputs and outputs (pitch
5.08 mm)
Removable screw terminal block for connecting the 24 V DC power supply (pitch 5.08 mm) |
|
cable distance between devices |
Unshielded cable: <= 50 m for input
Shielded cable: <= 10 m for fast input Unshielded cable: <= 50 m for output Shielded cable: <= 3 m for fast output |
|
insulation |
500 V AC between supply and internal logic
Non-insulated between supply and ground |
|
marking |
CE
|
|
sensor power supply |
24 V DC at 400 mA supplied by the controller
|
|
surge withstand |
2 kV for power lines (AC) in common mode conforming to EN/IEC
61000-4-5
2 kV for relay output in common mode conforming to EN/IEC 61000-4-5 1 kV for shielded cable in common mode conforming to EN/IEC 61000-4-5 1 kV for power lines (AC) in differential mode conforming to EN/IEC 61000-4-5 1 kV for relay output in differential mode conforming to EN/IEC 61000-4-5 1 kV for input in common mode conforming to EN/IEC 61000-4-5 1 kV for transistor output in common mode conforming to EN/IEC 61000-4-5 |
|
mounting support |
Top hat type TH35-15 rail conforming to IEC 60715
Top hat type TH35-7.5 rail conforming to IEC 60715 Plate or panel with fixing kit |
|
height |
90 mm
|
|
depth |
95 mm
|
|
width |
190 mm
|
|
product weight |
0.62 kg
|
standards |
CSA C22.2 No 142
ANSI/ISA 12-12-01 UL 1604 CSA C22.2 No 213 EN/IEC 61131-2 : 2007 Marine specification (LR, ABS, DNV, GL) UL 508 |
|
---|---|---|
product certifications |
CSA
RCM IACS E10 cULus |
|
resistance to electrostatic discharge |
4 kV on contact conforming to EN/IEC 61000-4-2
8 kV in air conforming to EN/IEC 61000-4-2 |
|
resistance to electromagnetic fields |
10 V/m (80 MHz...1 GHz) conforming to EN/IEC 61000-4-3
3 V/m (1.4 GHz...2 GHz) conforming to EN/IEC 61000-4-3 1 V/m (2 GHz...3 GHz) conforming to EN/IEC 61000-4-3 |
|
resistance to fast transients |
2 kV for power lines conforming to EN/IEC 61000-4-4
2 kV for relay output conforming to EN/IEC 61000-4-4 1 kV for serial link conforming to EN/IEC 61000-4-4 1 kV for input conforming to EN/IEC 61000-4-4 1 kV for transistor output conforming to EN/IEC 61000-4-4 |
|
resistance to conducted disturbances |
10 V (0.15...80 MHz) conforming to EN/IEC 61000-4-6
3 V (0.1...80 MHz) conforming to Marine specification (LR, ABS, DNV, GL) 10 V (spot frequency (2, 3, 4, 6.2, 8.2, 12.6, 16.5, 18.8, 22, 25 MHz)) conforming to Marine specification (LR, ABS, DNV, GL) |
|
electromagnetic emission |
Conducted emissions, test level: 120...69 dBµV/m QP, condition
of test: power lines (radio frequency: 10...150 kHz) conforming
to EN/IEC 55011
Conducted emissions, test level: 63 dBμV/m QP, condition of test: power lines (radio frequency: 1.5...30 MHz) conforming to EN/IEC 55011 Conducted emissions, test level: 79 dBμV/m QP/66 dBμV/m AV, condition of test: power lines (radio frequency: 0.15...0.5 MHz) conforming to EN/IEC 55011 Conducted emissions, test level: 73 dBμV/m QP/60 dBμV/m AV, condition of test: power lines (radio frequency: 0.5...300 MHz) conforming to EN/IEC 55011 Radiated emissions, test level: 40 dBμV/m QP with class A, condition of test: 10 m (radio frequency: 30...230 MHz) conforming to EN/IEC 55011 Conducted emissions, test level: 79...63 dBμV/m QP, condition of test: power lines (radio frequency: 150...1500 kHz) conforming to EN/IEC 55011 Radiated emissions, test level: 47 dBμV/m QP with class A, condition of test: 10 m (radio frequency: 230...1000 MHz) conforming to EN/IEC 55011 |
|
immunity to microbreaks |
10 ms
|
|
ambient air temperature for operation |
-10...55 °C for horizontal installation
-10...50 °C for vertical installation |
|
ambient air temperature for storage |
-25...70 °C
|
|
relative humidity |
10...95 % without condensation in operation
10...95 % without condensation in storage |
|
IP degree of protection |
IP20 with protective cover in place
|
|
pollution degree |
2
|
|
operating altitude |
0...2000 m
|
|
storage altitude |
0...3000 m
|
|
vibration resistance |
3.5 mm (vibration frequency: 5...8.4 Hz) on symmetrical rail
3 gn (vibration frequency: 8.4...150 Hz) on symmetrical rail 3.5 mm (vibration frequency: 5...8.4 Hz) on panel mounting 3 gn (vibration frequency: 8.4...150 Hz) on panel mounting |
|
shock resistance |
15 gn for 11 ms
|