Product Overview:
The Schneider TM241CE40R Controller M241 represents the pinnacle of industrial automation technology, meticulously designed to enhance operational efficiency and reliability. This advanced controller is engineered for diverse applications, offering robust performance with its comprehensive 40 I/O relay configuration and integrated Ethernet capabilities. Ideal for complex automation systems, the TM241CE40R ensures seamless communication, streamlined control, and unparalleled adaptability across various industrial environments.
Key Features:
40 I/O Relay Configuration: The TM241CE40R is equipped with 40 relay inputs and outputs, providing extensive connectivity options to accommodate a wide range of devices and sensors. This relay-based I/O configuration is perfect for applications requiring reliable switching and control of electrical circuits.
Integrated Ethernet Port: With built-in Ethernet connectivity, the TM241CE40R supports high-speed data communication and network integration. This feature enables efficient remote monitoring, programming, and control, facilitating real-time data exchange and system management.
Enhanced Processing Power: The controller boasts advanced processing capabilities, ensuring rapid execution of complex control algorithms and seamless handling of demanding tasks. Its superior processing speed contributes to reduced response times and increased operational efficiency.
Versatile Programming Options: The TM241CE40R is compatible with Schneider Electric’s EcoStruxure™ Control Expert software, offering a flexible and intuitive programming environment. This software suite allows for custom logic development, intuitive graphical programming, and comprehensive system diagnostics.
Robust Build Quality: Designed to withstand harsh industrial conditions, the TM241CE40R features a rugged construction that ensures long-term reliability and durability. Its high-quality components and superior engineering make it suitable for use in challenging environments.
Scalable and Modular Design: The controller's modular architecture allows for easy expansion and scalability. This design flexibility supports a wide range of applications, from small standalone systems to large, complex automation networks.
Applications:
The Schneider TM241CE40R Controller M241 is ideal for a variety of industrial automation applications, including but not limited to:
Manufacturing Processes: Efficiently manage and control machinery, production lines, and assembly systems with precision and reliability.
Building Automation: Integrate and automate HVAC systems, lighting controls, and security systems for enhanced operational efficiency and energy management.
Process Control: Monitor and regulate critical processes in industries such as pharmaceuticals, chemicals, and food and beverage manufacturing.
Technical Specifications:
- I/O Type: 40 Relay I/O
- Communication: Integrated Ethernet Port
- Programming Software: EcoStruxure™ Control Expert
- Operating Temperature Range: [Specify Range]
- Power Supply: [Specify Voltage/Current]
- Mounting Type: [Specify Mounting Type]
Why Choose Schneider TM241CE40R?
Schneider Electric’s TM241CE40R Controller M241 offers a combination of advanced features, reliability, and ease of integration that sets it apart in the industrial automation market. Its robust performance, flexible programming capabilities, and Ethernet connectivity make it an invaluable asset for enhancing the efficiency and functionality of modern automation systems.
For more information or to request a quote, please contact our sales team or visit our website.
range of product |
Modicon M241
|
|
---|---|---|
product or component type |
Logic controller
|
|
[Us] rated supply voltage |
100...240 V AC
|
|
discrete input number |
24 discrete input including 8 fast input conforming to IEC
61131-2 Type 1
|
|
discrete output type |
Relay
Transistor |
|
discrete output number |
12 relay
4 transistor including 4 fast output |
|
discrete output voltage |
24 V DC for transistor output
5...125 V DC for relay output 5...250 V AC for relay output |
|
discrete output current |
0.1 A with TR0...TR3 terminal(s) for fast output (PTO mode)
2 A with Q4...Q15 terminal(s) for relay output 0.5 A with TR0...TR3 terminal(s) for transistor output |
discrete I/O number |
40
|
|
---|---|---|
number of I/O expansion module |
7 (local I/O architecture)
14 (remote I/O architecture) |
|
supply voltage limits |
85...264 V
|
|
network frequency |
50/60 Hz
|
|
discrete input logic |
Sink or source
|
|
discrete input voltage |
24 V
|
|
discrete input voltage type |
DC
|
|
voltage state 1 guaranteed |
>= 15 V for input
|
|
voltage state 0 guaranteed |
<= 5 V for input
|
|
discrete input current |
7 mA for input
|
|
input impedance |
4.7 kOhm for input
|
|
response time |
50 µs turn-on operation with I0...I15 terminal(s) for input
|
|
configurable filtering time |
1 µs for fast input
|
|
discrete output logic |
Positive logic (source)
|
|
output voltage limits |
125 V DC relay output
30 V DC transistor output 277 V AC relay output |
|
output frequency |
<= 1 kHz for transistor output
<= 20 kHz for fast output (PWM mode) <= 100 kHz for fast output (PLS mode) |
|
accuracy |
+/- 0.1 % at 0.02...0.1 kHz for fast output
+/- 1 % at 0.1...1 kHz for fast output |
|
protection type |
Short-circuit protection for transistor output
Short-circuit and overload protection with automatic reset for transistor output Reverse polarity protection for transistor output Without protection for relay output |
|
reset time |
10 ms automatic reset output
12 s automatic reset fast output |
|
memory capacity |
8 MB for program
64 MB for system memory RAM |
|
data backed up |
128 MB built-in flash memory for backup of user programs
|
|
data storage equipment |
<= 16 GB SD card optional
|
|
battery type |
BR2032 lithium non-rechargeable, battery life: 4 yr
|
|
backup time |
2 years at 25 °C
|
|
execution time for 1 KInstruction |
0.3 ms for event and periodic task
0.7 ms for other instruction |
|
application structure |
4 cyclic master tasks
3 cyclic master tasks + 1 freewheeling task 8 event tasks 8 external event tasks |
|
realtime clock |
With
|
|
clock drift |
<= 60 s/month at 25 °C
|
|
positioning functions |
PTO function 4 channel(s) (positioning frequency: 100 kHz)
|
|
counting input number |
4 fast input (HSC mode) at 200 kHz
14 standard input at 1 kHz |
|
control signal type |
A/B signal at 100 kHz for fast input (HSC mode)
Pulse/direction signal at 200 kHz for fast input (HSC mode) Single phase signal at 200 kHz for fast input (HSC mode) |
|
integrated connection type |
USB port with connector mini B USB 2.0
Ethernet with connector RJ45 Non isolated serial link "serial 1" with connector RJ45 and interface RS232/RS485 Non isolated serial link "serial 2" with connector removable screw terminal block and interface RS485 |
|
supply |
Serial link supply "serial 1" at 5 V, <= 200 mA
|
|
transmission rate |
1.2...115.2 kbit/s (115.2 kbit/s by default) for bus length of
15 m - communication protocol: RS485
1.2...115.2 kbit/s (115.2 kbit/s by default) for bus length of 3 m - communication protocol: RS232 480 Mbit/s for bus length of 3 m - communication protocol: USB 10/100 Mbit/s - communication protocol: Ethernet |
|
communication port protocol |
Modbus non isolated serial link with master/slave method
|
|
port Ethernet |
1 - 10BASE-T/100BASE-TX port with copper cable support
|
|
ethernet services |
FDR
Downloading IEC VAR ACCESS Monitoring NGVL Programming Updating firmware SMS notifications DHCP server (via TM4 Ethernet switch network module) DHCP client (embedded Ethernet port) SNMP client/server FTP client/server SQL client Modbus TCP client I/O scanner Ethernet/IP originator I/O scanner (embedded Ethernet port) Ethernet/IP , Modbus TCP server and Modbus TCP slave Send and receive email from the controller based on TCP/UDP library Web server (WebVisu & XWeb system) OPC UA server DNS client |
|
local signalling |
1 LED green for SD card access (SD)
1 LED red for BAT 1 LED green for SL1 1 LED green for SL2 1 LED per channel green for I/O state 1 LED red for I/O error (I/O) 1 LED red for bus fault on TM4 (TM4) 1 LED green for Ethernet port activity 1 LED red for module error (ERR) 1 LED green for PWR 1 LED green for RUN |
|
electrical connection |
Removable screw terminal block for inputs and outputs (pitch
5.08 mm)
Removable screw terminal block for connecting the 24 V DC power supply (pitch 5.08 mm) |
|
cable distance between devices |
Unshielded cable: <= 50 m for input
Shielded cable: <= 10 m for fast input Unshielded cable: <= 50 m for output Shielded cable: <= 3 m for fast output |
|
insulation |
500 V AC between supply and internal logic
Non-insulated between supply and ground |
|
marking |
CE
|
|
sensor power supply |
24 V DC at 400 mA supplied by the controller
|
|
surge withstand |
2 kV for power lines (AC) in common mode conforming to EN/IEC
61000-4-5
2 kV for relay output in common mode conforming to EN/IEC 61000-4-5 1 kV for shielded cable in common mode conforming to EN/IEC 61000-4-5 1 kV for power lines (AC) in differential mode conforming to EN/IEC 61000-4-5 1 kV for relay output in differential mode conforming to EN/IEC 61000-4-5 1 kV for input in common mode conforming to EN/IEC 61000-4-5 1 kV for transistor output in common mode conforming to EN/IEC 61000-4-5 |
|
web services |
Web server
|
|
maximum number of connections |
8 connection(s) for Modbus server
8 connection(s) for SoMachine protocol 10 connection(s) for web server 4 connection(s) for FTP server 16 connection(s) for Ethernet/IP 8 connection(s) for Modbus client |
|
number of slave |
16 Ethernet/IP
64 Modbus TCP |
|
cycle time |
10 ms 16 Ethernet/IP
64 ms 64 Modbus TCP |
|
mounting support |
Top hat type TH35-15 rail conforming to IEC 60715
Top hat type TH35-7.5 rail conforming to IEC 60715 Plate or panel with fixing kit |
|
height |
90 mm
|
|
depth |
95 mm
|
|
width |
190 mm
|
|
product weight |
0.62 kg
|
standards |
CSA C22.2 No 142
ANSI/ISA 12-12-01 UL 1604 CSA C22.2 No 213 EN/IEC 61131-2 : 2007 Marine specification (LR, ABS, DNV, GL) UL 508 |
|
---|---|---|
product certifications |
IACS E10
RCM CSA cULus |
|
resistance to electrostatic discharge |
4 kV on contact conforming to EN/IEC 61000-4-2
8 kV in air conforming to EN/IEC 61000-4-2 |
|
resistance to electromagnetic fields |
10 V/m (80 MHz...1 GHz) conforming to EN/IEC 61000-4-3
3 V/m (1.4 GHz...2 GHz) conforming to EN/IEC 61000-4-3 1 V/m (2 GHz...3 GHz) conforming to EN/IEC 61000-4-3 |
|
resistance to fast transients |
2 kV for power lines conforming to EN/IEC 61000-4-4
2 kV for relay output conforming to EN/IEC 61000-4-4 1 kV for Ethernet line conforming to EN/IEC 61000-4-4 1 kV for serial link conforming to EN/IEC 61000-4-4 1 kV for input conforming to EN/IEC 61000-4-4 1 kV for transistor output conforming to EN/IEC 61000-4-4 |
|
resistance to conducted disturbances |
10 V (0.15...80 MHz) conforming to EN/IEC 61000-4-6
3 V (0.1...80 MHz) conforming to Marine specification (LR, ABS, DNV, GL) 10 V (spot frequency (2, 3, 4, 6.2, 8.2, 12.6, 16.5, 18.8, 22, 25 MHz)) conforming to Marine specification (LR, ABS, DNV, GL) |
|
electromagnetic emission |
Conducted emissions, test level: 120...69 dBµV/m QP, condition
of test: power lines (radio frequency: 10...150 kHz) conforming
to EN/IEC 55011
Conducted emissions, test level: 63 dBμV/m QP, condition of test: power lines (radio frequency: 1.5...30 MHz) conforming to EN/IEC 55011 Conducted emissions, test level: 79 dBμV/m QP/66 dBμV/m AV, condition of test: power lines (radio frequency: 0.15...0.5 MHz) conforming to EN/IEC 55011 Conducted emissions, test level: 73 dBμV/m QP/60 dBμV/m AV, condition of test: power lines (radio frequency: 0.5...300 MHz) conforming to EN/IEC 55011 Radiated emissions, test level: 40 dBμV/m QP with class A, condition of test: 10 m (radio frequency: 30...230 MHz) conforming to EN/IEC 55011 Conducted emissions, test level: 79...63 dBμV/m QP, condition of test: power lines (radio frequency: 150...1500 kHz) conforming to EN/IEC 55011 Radiated emissions, test level: 47 dBμV/m QP with class A, condition of test: 10 m (radio frequency: 230...1000 MHz) conforming to EN/IEC 55011 |
|
immunity to microbreaks |
10 ms
|
|
ambient air temperature for operation |
-10...55 °C for horizontal installation
-10...50 °C for vertical installation |
|
ambient air temperature for storage |
-25...70 °C
|
|
relative humidity |
10...95 % without condensation in operation
10...95 % without condensation in storage |
|
IP degree of protection |
IP20 with protective cover in place
|
|
pollution degree |
2
|
|
operating altitude |
0...2000 m
|
|
storage altitude |
0...3000 m
|
|
vibration resistance |
3.5 mm (vibration frequency: 5...8.4 Hz) on symmetrical rail
3 gn (vibration frequency: 8.4...150 Hz) on symmetrical rail 3.5 mm (vibration frequency: 5...8.4 Hz) on panel mounting 3 gn (vibration frequency: 8.4...150 Hz) on panel mounting |
|
shock resistance |
15 gn for 11 ms
|