• Schneider TM241CE40R Controller M241 - 40 I/O Relay with Ethernet Connectivity

Schneider TM241CE40R Controller M241 - 40 I/O Relay with Ethernet Connectivity

Product Overview:

The Schneider TM241CE40R Controller M241 represents the pinnacle of industrial automation technology, meticulously designed to enhance operational efficiency and reliability. This advanced controller is engineered for diverse applications, offering robust performance with its comprehensive 40 I/O relay configuration and integrated Ethernet capabilities. Ideal for complex automation systems, the TM241CE40R ensures seamless communication, streamlined control, and unparalleled adaptability across various industrial environments.

Key Features:

  • 40 I/O Relay Configuration: The TM241CE40R is equipped with 40 relay inputs and outputs, providing extensive connectivity options to accommodate a wide range of devices and sensors. This relay-based I/O configuration is perfect for applications requiring reliable switching and control of electrical circuits.

  • Integrated Ethernet Port: With built-in Ethernet connectivity, the TM241CE40R supports high-speed data communication and network integration. This feature enables efficient remote monitoring, programming, and control, facilitating real-time data exchange and system management.

  • Enhanced Processing Power: The controller boasts advanced processing capabilities, ensuring rapid execution of complex control algorithms and seamless handling of demanding tasks. Its superior processing speed contributes to reduced response times and increased operational efficiency.

  • Versatile Programming Options: The TM241CE40R is compatible with Schneider Electric’s EcoStruxure™ Control Expert software, offering a flexible and intuitive programming environment. This software suite allows for custom logic development, intuitive graphical programming, and comprehensive system diagnostics.

  • Robust Build Quality: Designed to withstand harsh industrial conditions, the TM241CE40R features a rugged construction that ensures long-term reliability and durability. Its high-quality components and superior engineering make it suitable for use in challenging environments.

  • Scalable and Modular Design: The controller's modular architecture allows for easy expansion and scalability. This design flexibility supports a wide range of applications, from small standalone systems to large, complex automation networks.

Applications:

The Schneider TM241CE40R Controller M241 is ideal for a variety of industrial automation applications, including but not limited to:

  • Manufacturing Processes: Efficiently manage and control machinery, production lines, and assembly systems with precision and reliability.

  • Building Automation: Integrate and automate HVAC systems, lighting controls, and security systems for enhanced operational efficiency and energy management.

  • Process Control: Monitor and regulate critical processes in industries such as pharmaceuticals, chemicals, and food and beverage manufacturing.

Technical Specifications:

  • I/O Type: 40 Relay I/O
  • Communication: Integrated Ethernet Port
  • Programming Software: EcoStruxure™ Control Expert
  • Operating Temperature Range: [Specify Range]
  • Power Supply: [Specify Voltage/Current]
  • Mounting Type: [Specify Mounting Type]

Why Choose Schneider TM241CE40R?

Schneider Electric’s TM241CE40R Controller M241 offers a combination of advanced features, reliability, and ease of integration that sets it apart in the industrial automation market. Its robust performance, flexible programming capabilities, and Ethernet connectivity make it an invaluable asset for enhancing the efficiency and functionality of modern automation systems.

For more information or to request a quote, please contact our sales team or visit our website.

Main
range of product
Modicon M241
product or component type
Logic controller
[Us] rated supply voltage
100...240 V AC
discrete input number
24 discrete input including 8 fast input conforming to IEC 61131-2 Type 1
discrete output type
Relay
Transistor
discrete output number
12 relay
4 transistor including 4 fast output
discrete output voltage
24 V DC for transistor output
5...125 V DC for relay output
5...250 V AC for relay output
discrete output current
0.1 A with TR0...TR3 terminal(s) for fast output (PTO mode)
2 A with Q4...Q15 terminal(s) for relay output
0.5 A with TR0...TR3 terminal(s) for transistor output
Complementary
discrete I/O number
40
number of I/O expansion module
7 (local I/O architecture)
14 (remote I/O architecture)
supply voltage limits
85...264 V
network frequency
50/60 Hz
discrete input logic
Sink or source
discrete input voltage
24 V
discrete input voltage type
DC
voltage state 1 guaranteed
>= 15 V for input
voltage state 0 guaranteed
<= 5 V for input
discrete input current
7 mA for input
input impedance
4.7 kOhm for input
response time
50 µs turn-on operation with I0...I15 terminal(s) for input
configurable filtering time
1 µs for fast input
discrete output logic
Positive logic (source)
output voltage limits
125 V DC relay output
30 V DC transistor output
277 V AC relay output
output frequency
<= 1 kHz for transistor output
<= 20 kHz for fast output (PWM mode)
<= 100 kHz for fast output (PLS mode)
accuracy
+/- 0.1 % at 0.02...0.1 kHz for fast output
+/- 1 % at 0.1...1 kHz for fast output
protection type
Short-circuit protection for transistor output
Short-circuit and overload protection with automatic reset for transistor output
Reverse polarity protection for transistor output
Without protection for relay output
reset time
10 ms automatic reset output
12 s automatic reset fast output
memory capacity
8 MB for program
64 MB for system memory RAM
data backed up
128 MB built-in flash memory for backup of user programs
data storage equipment
<= 16 GB SD card optional
battery type
BR2032 lithium non-rechargeable, battery life: 4 yr
backup time
2 years at 25 °C
execution time for 1 KInstruction
0.3 ms for event and periodic task
0.7 ms for other instruction
application structure
4 cyclic master tasks
3 cyclic master tasks + 1 freewheeling task
8 event tasks
8 external event tasks
realtime clock
With
clock drift
<= 60 s/month at 25 °C
positioning functions
PTO function 4 channel(s) (positioning frequency: 100 kHz)
counting input number
4 fast input (HSC mode) at 200 kHz
14 standard input at 1 kHz
control signal type
A/B signal at 100 kHz for fast input (HSC mode)
Pulse/direction signal at 200 kHz for fast input (HSC mode)
Single phase signal at 200 kHz for fast input (HSC mode)
integrated connection type
USB port with connector mini B USB 2.0
Ethernet with connector RJ45
Non isolated serial link "serial 1" with connector RJ45 and interface RS232/RS485
Non isolated serial link "serial 2" with connector removable screw terminal block and interface RS485
supply
Serial link supply "serial 1" at 5 V, <= 200 mA
transmission rate
1.2...115.2 kbit/s (115.2 kbit/s by default) for bus length of 15 m - communication protocol: RS485
1.2...115.2 kbit/s (115.2 kbit/s by default) for bus length of 3 m - communication protocol: RS232
480 Mbit/s for bus length of 3 m - communication protocol: USB
10/100 Mbit/s - communication protocol: Ethernet
communication port protocol
Modbus non isolated serial link with master/slave method
port Ethernet
1 - 10BASE-T/100BASE-TX port with copper cable support
ethernet services
FDR
Downloading
IEC VAR ACCESS
Monitoring
NGVL
Programming
Updating firmware
SMS notifications
DHCP server (via TM4 Ethernet switch network module)
DHCP client (embedded Ethernet port)
SNMP client/server
FTP client/server
SQL client
Modbus TCP client I/O scanner
Ethernet/IP originator I/O scanner (embedded Ethernet port)
Ethernet/IP target, Modbus TCP server and Modbus TCP slave
Send and receive email from the controller based on TCP/UDP library
Web server (WebVisu & XWeb system)
OPC UA server
DNS client
local signalling
1 LED green for SD card access (SD)
1 LED red for BAT
1 LED green for SL1
1 LED green for SL2
1 LED per channel green for I/O state
1 LED red for I/O error (I/O)
1 LED red for bus fault on TM4 (TM4)
1 LED green for Ethernet port activity
1 LED red for module error (ERR)
1 LED green for PWR
1 LED green for RUN
electrical connection
Removable screw terminal block for inputs and outputs (pitch 5.08 mm)
Removable screw terminal block for connecting the 24 V DC power supply (pitch 5.08 mm)
cable distance between devices
Unshielded cable: <= 50 m for input
Shielded cable: <= 10 m for fast input
Unshielded cable: <= 50 m for output
Shielded cable: <= 3 m for fast output
insulation
500 V AC between supply and internal logic
Non-insulated between supply and ground
marking
CE
sensor power supply
24 V DC at 400 mA supplied by the controller
surge withstand
2 kV for power lines (AC) in common mode conforming to EN/IEC 61000-4-5
2 kV for relay output in common mode conforming to EN/IEC 61000-4-5
1 kV for shielded cable in common mode conforming to EN/IEC 61000-4-5
1 kV for power lines (AC) in differential mode conforming to EN/IEC 61000-4-5
1 kV for relay output in differential mode conforming to EN/IEC 61000-4-5
1 kV for input in common mode conforming to EN/IEC 61000-4-5
1 kV for transistor output in common mode conforming to EN/IEC 61000-4-5
web services
Web server
maximum number of connections
8 connection(s) for Modbus server
8 connection(s) for SoMachine protocol
10 connection(s) for web server
4 connection(s) for FTP server
16 connection(s) for Ethernet/IP target
8 connection(s) for Modbus client
number of slave
16 Ethernet/IP
64 Modbus TCP
cycle time
10 ms 16 Ethernet/IP
64 ms 64 Modbus TCP
mounting support
Top hat type TH35-15 rail conforming to IEC 60715
Top hat type TH35-7.5 rail conforming to IEC 60715
Plate or panel with fixing kit
height
90 mm
depth
95 mm
width
190 mm
product weight
0.62 kg

Environment
standards
CSA C22.2 No 142
ANSI/ISA 12-12-01
UL 1604
CSA C22.2 No 213
EN/IEC 61131-2 : 2007
Marine specification (LR, ABS, DNV, GL)
UL 508
product certifications
IACS E10
RCM
CSA
cULus
resistance to electrostatic discharge
4 kV on contact conforming to EN/IEC 61000-4-2
8 kV in air conforming to EN/IEC 61000-4-2
resistance to electromagnetic fields
10 V/m (80 MHz...1 GHz) conforming to EN/IEC 61000-4-3
3 V/m (1.4 GHz...2 GHz) conforming to EN/IEC 61000-4-3
1 V/m (2 GHz...3 GHz) conforming to EN/IEC 61000-4-3
resistance to fast transients
2 kV for power lines conforming to EN/IEC 61000-4-4
2 kV for relay output conforming to EN/IEC 61000-4-4
1 kV for Ethernet line conforming to EN/IEC 61000-4-4
1 kV for serial link conforming to EN/IEC 61000-4-4
1 kV for input conforming to EN/IEC 61000-4-4
1 kV for transistor output conforming to EN/IEC 61000-4-4
resistance to conducted disturbances
10 V (0.15...80 MHz) conforming to EN/IEC 61000-4-6
3 V (0.1...80 MHz) conforming to Marine specification (LR, ABS, DNV, GL)
10 V (spot frequency (2, 3, 4, 6.2, 8.2, 12.6, 16.5, 18.8, 22, 25 MHz)) conforming to Marine specification (LR, ABS, DNV, GL)
electromagnetic emission
Conducted emissions, test level: 120...69 dBµV/m QP, condition of test: power lines (radio frequency: 10...150 kHz) conforming to EN/IEC 55011
Conducted emissions, test level: 63 dBμV/m QP, condition of test: power lines (radio frequency: 1.5...30 MHz) conforming to EN/IEC 55011
Conducted emissions, test level: 79 dBμV/m QP/66 dBμV/m AV, condition of test: power lines (radio frequency: 0.15...0.5 MHz) conforming to EN/IEC 55011
Conducted emissions, test level: 73 dBμV/m QP/60 dBμV/m AV, condition of test: power lines (radio frequency: 0.5...300 MHz) conforming to EN/IEC 55011
Radiated emissions, test level: 40 dBμV/m QP with class A, condition of test: 10 m (radio frequency: 30...230 MHz) conforming to EN/IEC 55011
Conducted emissions, test level: 79...63 dBμV/m QP, condition of test: power lines (radio frequency: 150...1500 kHz) conforming to EN/IEC 55011
Radiated emissions, test level: 47 dBμV/m QP with class A, condition of test: 10 m (radio frequency: 230...1000 MHz) conforming to EN/IEC 55011
immunity to microbreaks
10 ms
ambient air temperature for operation
-10...55 °C for horizontal installation
-10...50 °C for vertical installation
ambient air temperature for storage
-25...70 °C
relative humidity
10...95 % without condensation in operation
10...95 % without condensation in storage
IP degree of protection
IP20 with protective cover in place
pollution degree
2
operating altitude
0...2000 m
storage altitude
0...3000 m
vibration resistance
3.5 mm (vibration frequency: 5...8.4 Hz) on symmetrical rail
3 gn (vibration frequency: 8.4...150 Hz) on symmetrical rail
3.5 mm (vibration frequency: 5...8.4 Hz) on panel mounting
3 gn (vibration frequency: 8.4...150 Hz) on panel mounting
shock resistance
15 gn for 11 ms

Schneider TM241CE40R Controller M241 - 40 I/O Relay with Ethernet Connectivity

  • Brand: Schneider
  • Product Code: TM241CE40R
  • Availability: 1000

Tags: Schneider TM241CE40R, Controller M241, 40 I/O Relay, Ethernet Connectivity, Industrial Automation, Schneider Electric, Automation Controller, M241 Series, Relay I/O Controller, Ethernet Automation Solution