Schneider TM241CE40T Controller M241 - 40 IO Transistor PNP Ethernet
Elevate your automation systems with the Schneider TM241CE40T Controller M241, a cutting-edge solution designed for superior control and efficiency. The TM241CE40T is an advanced programmable logic controller (PLC) engineered for complex industrial applications that demand precision, reliability, and seamless integration.
Key Features:
40 I/O Ports: The TM241CE40T features 40 digital input/output (I/O) ports, providing robust connectivity options. Each port is designed with transistor PNP technology to ensure high-speed, reliable signal processing and minimal maintenance requirements.
Ethernet Connectivity: Equipped with built-in Ethernet capabilities, this controller facilitates high-speed communication and network integration. The Ethernet interface supports various industrial protocols, enabling seamless data exchange and remote monitoring for enhanced operational flexibility.
Scalable Architecture: The M241 series offers modularity and scalability to adapt to evolving automation needs. The TM241CE40T is designed to integrate effortlessly with other Schneider Electric components and systems, providing a scalable solution for diverse applications.
Enhanced Processing Power: Powered by an advanced processor, the TM241CE40T delivers exceptional performance for real-time control tasks. The controller’s processing capabilities ensure efficient execution of complex algorithms and swift response times.
Intuitive Programming Environment: Schneider Electric’s EcoStruxure™ Control Expert (formerly Unity Pro) provides an intuitive programming environment for the TM241CE40T. This user-friendly software streamlines development, debugging, and deployment processes, enhancing productivity and reducing time-to-market.
Robust Design: Engineered for durability, the TM241CE40T is built to withstand harsh industrial environments. Its rugged design ensures reliable operation under challenging conditions, making it ideal for a wide range of applications.
Compliance and Certification: The TM241CE40T adheres to international standards and certifications, ensuring compliance with industry regulations and compatibility with global systems.
Applications:
The Schneider TM241CE40T Controller M241 is ideal for a variety of industrial automation applications, including:
- Manufacturing Automation: Streamline manufacturing processes with precise control and real-time monitoring.
- Process Control: Manage and optimize complex processes with enhanced processing power and connectivity.
- Building Automation: Integrate with building management systems for efficient control of HVAC, lighting, and other infrastructure systems.
Technical Specifications:
- I/O Configuration: 40 Digital I/O (Transistor PNP)
- Communication: Ethernet Port
- Processor: High-performance Processor
- Programming Software: EcoStruxure™ Control Expert
- Environmental Ratings: Designed for industrial use with rugged construction
Enhance your automation capabilities with the Schneider TM241CE40T Controller M241. Its advanced features and robust design ensure reliable performance, scalability, and ease of integration in complex industrial environments.
Optimize your industrial processes with Schneider Electric’s cutting-edge technology. For more information and technical support, contact us today.
SEO Keywords: Schneider TM241CE40T, M241 Controller, 40 IO Transistor PNP, Ethernet PLC, Schneider Electric Automation, Industrial Controller, EcoStruxure Control Expert, High-performance PLC
range of product |
Modicon M241
|
|
---|---|---|
product or component type |
Logic controller
|
|
[Us] rated supply voltage |
24 V DC
|
|
discrete input number |
24 discrete input including 8 fast input conforming to IEC
61131-2 Type 1
|
|
discrete output type |
Transistor
|
|
discrete output number |
16 transistor including 4 fast output
|
|
discrete output voltage |
24 V DC for transistor output
|
|
discrete output current |
0.1 A with Q0...Q3 terminal(s) for fast output (PTO mode)
0.5 A with Q0...Q15 terminal(s) for transistor output |
discrete I/O number |
40
|
|
---|---|---|
number of I/O expansion module |
7 (local I/O architecture)
14 (remote I/O architecture) |
|
supply voltage limits |
20.4...28.8 V
|
|
inrush current |
50 A
|
|
power consumption in W |
32.6...40.4 W with max number of I/O expansion module
|
|
discrete input logic |
Sink or source
|
|
discrete input voltage |
24 V
|
|
discrete input voltage type |
DC
|
|
voltage state 1 guaranteed |
>= 15 V for input
|
|
voltage state 0 guaranteed |
<= 5 V for input
|
|
discrete input current |
7 mA for input
10.7 mA for fast input |
|
input impedance |
4.7 kOhm for input
2.81 kOhm for fast input |
|
response time |
<= 2 µs turn-on operation with I0...I7 terminal(s) for fast
input
<= 2 µs turn-off operation with I0...I7 terminal(s) for fast input <= 2 µs turn-on operation with Q0...Q3 terminal(s) for fast output <= 2 µs turn-off operation with Q0...Q3 terminal(s) for fast output 50 µs turn-on operation with I0...I15 terminal(s) for input 50 µs turn-off operation with I0...I15 terminal(s) for input <= 34 µs turn-on operation with Q0...Q15 terminal(s) for output <= 250 µs turn-off operation with Q0...Q15 terminal(s) for output |
|
configurable filtering time |
1 µs for fast input
12 ms for fast input 0 ms for input 1 ms for input 4 ms for input 12 ms for input |
|
discrete output logic |
Positive logic (source)
|
|
output voltage limits |
30 V DC
|
|
current per output common |
<= 2 A
|
|
output frequency |
<= 20 kHz for fast output (PWM mode)
<= 100 kHz for fast output (PLS mode) <= 1 kHz for output |
|
accuracy |
+/- 0.1 % at 0.02...0.1 kHz for fast output
+/- 1 % at 0.1...1 kHz for fast output |
|
leakage current |
<= 5 µA for output
|
|
voltage drop |
<= 1 V
|
|
tungsten load |
<= 2.4 W
|
|
protection type |
Short-circuit and overload protection with automatic reset
Reverse polarity protection for fast output Short-circuit protection |
|
reset time |
10 ms automatic reset output
12 s automatic reset fast output |
|
memory capacity |
8 MB for program
64 MB for system memory RAM |
|
data backed up |
128 MB built-in flash memory for backup of user programs
|
|
data storage equipment |
<= 16 GB SD card optional
|
|
battery type |
BR2032 lithium non-rechargeable, battery life: 4 yr
|
|
backup time |
2 years at 25 °C
|
|
execution time for 1 KInstruction |
0.3 ms for event and periodic task
0.7 ms for other instruction |
|
application structure |
4 cyclic master tasks
8 external event tasks 3 cyclic master tasks + 1 freewheeling task 8 event tasks |
|
realtime clock |
With
|
|
clock drift |
<= 60 s/month at 25 °C
|
|
positioning functions |
PTO function 4 channel(s) (positioning frequency: 100 kHz)
PTO function 4 channel(s) for transistor output (positioning frequency: 1 kHz) |
|
counting input number |
4 fast input (HSC mode) at 200 kHz
16 standard input at 1 kHz |
|
control signal type |
A/B signal at 100 kHz for fast input (HSC mode)
Pulse/direction signal at 200 kHz for fast input (HSC mode) Single phase signal at 200 kHz for fast input (HSC mode) |
|
integrated connection type |
USB port with connector mini B USB 2.0
Ethernet with connector RJ45 Non isolated serial link "serial 1" with connector RJ45 and interface RS232/RS485 Non isolated serial link "serial 2" with connector removable screw terminal block and interface RS485 |
|
supply |
Serial link supply "serial 1" at 5 V, <= 200 mA
|
|
transmission rate |
1.2...115.2 kbit/s (115.2 kbit/s by default) for bus length of
15 m - communication protocol: RS485
1.2...115.2 kbit/s (115.2 kbit/s by default) for bus length of 3 m - communication protocol: RS232 480 Mbit/s for bus length of 3 m - communication protocol: USB 10/100 Mbit/s - communication protocol: Ethernet |
|
communication port protocol |
Modbus non isolated serial link with master/slave method
|
|
port Ethernet |
1 - 10BASE-T/100BASE-TX port with copper cable support
|
|
ethernet services |
FDR
Downloading IEC VAR ACCESS Monitoring NGVL Programming Updating firmware SMS notifications DHCP server (via TM4 Ethernet switch network module) DHCP client (embedded Ethernet port) SNMP client/server FTP client/server SQL client Modbus TCP client I/O scanner Ethernet/IP originator I/O scanner (embedded Ethernet port) Ethernet/IP , Modbus TCP server and Modbus TCP slave Send and receive email from the controller based on TCP/UDP library Web server (WebVisu & XWeb system) OPC UA server DNS client |
|
local signalling |
1 LED green for SD card access (SD)
1 LED red for BAT 1 LED green for SL1 1 LED green for SL2 1 LED per channel green for I/O state 1 LED red for I/O error (I/O) 1 LED red for bus fault on TM4 (TM4) 1 LED green for Ethernet port activity 1 LED red for module error (ERR) 1 LED green for PWR 1 LED green for RUN |
|
electrical connection |
Removable screw terminal block for inputs and outputs (pitch
5.08 mm)
Removable screw terminal block for connecting the 24 V DC power supply (pitch 5.08 mm) |
|
cable distance between devices |
Unshielded cable: <= 50 m for input
Shielded cable: <= 10 m for fast input Unshielded cable: <= 50 m for output Shielded cable: <= 3 m for fast output |
|
insulation |
500 V AC between fast input and internal logic
Non-insulated between inputs 500 V AC between output and internal logic 500 V AC between fast output and internal logic Non-insulated between outputs 500 V AC between input and internal logic 500 V AC between output groups 500 V AC between supply and internal logic Non-insulated between supply and ground |
|
marking |
CE
|
|
surge withstand |
1 kV for power lines (DC) in common mode conforming to EN/IEC
61000-4-5
1 kV for shielded cable in common mode conforming to EN/IEC 61000-4-5 0.5 kV for power lines (DC) in differential mode conforming to EN/IEC 61000-4-5 1 kV for relay output in differential mode conforming to EN/IEC 61000-4-5 1 kV for input in common mode conforming to EN/IEC 61000-4-5 1 kV for transistor output in common mode conforming to EN/IEC 61000-4-5 |
|
web services |
Web server
|
|
maximum number of connections |
8 connection(s) for Modbus server
8 connection(s) for SoMachine protocol 10 connection(s) for web server 4 connection(s) for FTP server 16 connection(s) for Ethernet/IP 8 connection(s) for Modbus client |
|
number of slave |
16 Ethernet/IP
64 Modbus TCP |
|
cycle time |
10 ms 16 Ethernet/IP
64 ms 64 Modbus TCP |
|
mounting support |
Top hat type TH35-15 rail conforming to IEC 60715
Top hat type TH35-7.5 rail conforming to IEC 60715 Plate or panel with fixing kit |
|
height |
90 mm
|
|
depth |
95 mm
|
|
width |
190 mm
|
|
product weight |
0.62 kg
|
standards |
CSA C22.2 No 142
ANSI/ISA 12-12-01 UL 1604 CSA C22.2 No 213 EN/IEC 61131-2 : 2007 Marine specification (LR, ABS, DNV, GL) UL 508 |
|
---|---|---|
product certifications |
CSA
cULus RCM IACS E10 |
|
resistance to electrostatic discharge |
4 kV on contact conforming to EN/IEC 61000-4-2
8 kV in air conforming to EN/IEC 61000-4-2 |
|
resistance to electromagnetic fields |
10 V/m (80 MHz...1 GHz) conforming to EN/IEC 61000-4-3
3 V/m (1.4 GHz...2 GHz) conforming to EN/IEC 61000-4-3 1 V/m (2 GHz...3 GHz) conforming to EN/IEC 61000-4-3 |
|
resistance to fast transients |
2 kV for power lines conforming to EN/IEC 61000-4-4
1 kV for Ethernet line conforming to EN/IEC 61000-4-4 1 kV for serial link conforming to EN/IEC 61000-4-4 1 kV for input conforming to EN/IEC 61000-4-4 1 kV for transistor output conforming to EN/IEC 61000-4-4 |
|
resistance to conducted disturbances |
10 V (0.15...80 MHz) conforming to EN/IEC 61000-4-6
3 V (0.1...80 MHz) conforming to Marine specification (LR, ABS, DNV, GL) 10 V (spot frequency (2, 3, 4, 6.2, 8.2, 12.6, 16.5, 18.8, 22, 25 MHz)) conforming to Marine specification (LR, ABS, DNV, GL) |
|
electromagnetic emission |
Conducted emissions, test level: 120...69 dBµV/m QP, condition
of test: power lines (radio frequency: 10...150 kHz) conforming
to EN/IEC 55011
Conducted emissions, test level: 63 dBμV/m QP, condition of test: power lines (radio frequency: 1.5...30 MHz) conforming to EN/IEC 55011 Radiated emissions, test level: 40 dBμV/m QP with class A (radio frequency: 30...230 MHz) conforming to EN/IEC 55011 Conducted emissions, test level: 79...63 dBμV/m QP, condition of test: power lines (radio frequency: 150...1500 kHz) conforming to EN/IEC 55011 Radiated emissions, test level: 47 dBμV/m QP with class A (radio frequency: 230...1000 MHz) conforming to EN/IEC 55011 |
|
immunity to microbreaks |
10 ms
|
|
ambient air temperature for operation |
-10...55 °C for horizontal installation
-10...50 °C for vertical installation |
|
ambient air temperature for storage |
-25...70 °C
|
|
relative humidity |
10...95 % without condensation in operation
10...95 % without condensation in storage |
|
IP degree of protection |
IP20 with protective cover in place
|
|
pollution degree |
2
|
|
operating altitude |
0...2000 m
|
|
storage altitude |
0...3000 m
|
|
vibration resistance |
3.5 mm (vibration frequency: 5...8.4 Hz) on symmetrical rail
3 gn (vibration frequency: 8.4...150 Hz) on symmetrical rail 3.5 mm (vibration frequency: 5...8.4 Hz) on panel mounting 3 gn (vibration frequency: 8.4...150 Hz) on panel mounting |
|
shock resistance |
15 gn for 11 ms
|