Schneider TM241CEC24T Controller M241 - 24 I/O Transistor PNP, Ethernet, CAN Master
Unlock unparalleled control and efficiency with the Schneider TM241CEC24T Controller M241, engineered to elevate your automation systems. This advanced programmable logic controller (PLC) integrates a robust array of features designed to enhance operational performance and system integration, making it the ideal choice for complex industrial applications.
Key Features:
24 Digital I/O Channels: The TM241CEC24T is equipped with 24 high-speed digital inputs and outputs, utilizing transistor PNP technology. This configuration ensures rapid response times and reliable signal processing for dynamic control tasks.
Integrated Ethernet Interface: The controller features a built-in Ethernet port, enabling seamless communication with other networked devices. This connectivity supports fast data exchange, remote diagnostics, and simplified integration with existing network infrastructures.
CAN Master Protocol: With the CAN (Controller Area Network) master functionality, the TM241CEC24T offers superior control over distributed network systems. The CAN interface enhances communication between devices, facilitating real-time data exchange and system synchronization.
Advanced Programming Capabilities: Schneider’s M241 series supports a range of programming languages and environments, including IEC 61131-3 compliant languages. This flexibility allows for customized solutions tailored to specific application needs.
Compact and Robust Design: The TM241CEC24T is engineered for durability and space-efficiency, featuring a compact form factor that fits easily into tight control panels while withstanding the rigors of industrial environments.
Enhanced Diagnostic Features: Equipped with comprehensive diagnostic tools, the M241 controller simplifies troubleshooting and maintenance, helping to minimize downtime and ensure continuous operational efficiency.
Scalable and Flexible: Designed to accommodate a variety of automation needs, the TM241CEC24T supports scalable solutions, enabling users to expand their control systems as their requirements evolve.
Applications:
The Schneider TM241CEC24T is ideally suited for applications in manufacturing, process control, building automation, and other industrial environments where precision and reliability are paramount. Its advanced features make it a versatile choice for both new installations and retrofits of existing systems.
Benefits:
- Increased Efficiency: The high-speed digital I/O and advanced communication protocols streamline processes and enhance operational efficiency.
- Seamless Integration: With Ethernet and CAN master capabilities, integration with existing systems and networks is both straightforward and flexible.
- Reliability: Built to withstand harsh industrial conditions, ensuring long-term reliability and performance.
Specifications:
- Model: TM241CEC24T
- I/O Type: 24 Digital Transistor PNP
- Ethernet Interface: Integrated
- CAN Interface: Master
- Programming Languages: IEC 61131-3
- Dimensions: [Insert Dimensions]
- Weight: [Insert Weight]
Elevate your automation capabilities with the Schneider TM241CEC24T Controller M241. Its combination of high performance, advanced connectivity, and robust design makes it the perfect solution for demanding control applications. For more information or to request a quote, please contact our sales team today.
range of product |
Modicon M241
|
|
---|---|---|
product or component type |
Logic controller
|
|
[Us] rated supply voltage |
24 V DC
|
|
discrete input number |
14 discrete input including 8 fast input conforming to IEC
61131-2 Type 1
|
|
discrete output type |
Transistor
|
|
discrete output number |
10 transistor including 4 fast output
|
|
discrete output voltage |
24 V DC for transistor output
|
|
discrete output current |
0.5 A with Q0...Q9 terminal(s) for transistor output
0.1 A with Q0...Q3 terminal(s) for fast output (PTO mode) |
discrete I/O number |
24
|
|
---|---|---|
number of I/O expansion module |
7 (local I/O architecture)
14 (remote I/O architecture) |
|
supply voltage limits |
20.4...28.8 V
|
|
inrush current |
50 A
|
|
power consumption in W |
32.6...40.4 W with max number of I/O expansion module
|
|
discrete input logic |
Sink or source
|
|
discrete input voltage |
24 V
|
|
discrete input voltage type |
DC
|
|
voltage state 1 guaranteed |
>= 15 V for input
|
|
voltage state 0 guaranteed |
<= 5 V for input
|
|
discrete input current |
5 mA for input
10.7 mA for fast input |
|
input impedance |
4.7 kOhm for input
2.81 kOhm for fast input |
|
response time |
50 µs turn-on operation with I0...I13 terminal(s) for input
50 µs turn-off operation with I0...I13 terminal(s) for input <= 2 µs turn-on operation with I0...I7 terminal(s) for fast input <= 2 µs turn-off operation with I0...I7 terminal(s) for fast input <= 34 µs turn-on operation with Q0...Q9 terminal(s) for output <= 250 µs turn-off operation with Q0...Q9 terminal(s) for output <= 2 µs turn-on operation with Q0...Q3 terminal(s) for fast output <= 2 µs turn-off operation with Q0...Q3 terminal(s) for fast output |
|
configurable filtering time |
1 µs for fast input
12 ms for fast input 0 ms for input 1 ms for input 4 ms for input 12 ms for input |
|
discrete output logic |
Positive logic (source)
|
|
output voltage limits |
30 V DC
|
|
current per output common |
<= 2 A with Q0...Q3 terminal for fast output
<= 2 A with Q4...Q7 terminal for output <= 1 A with Q8...Q9 terminal for output |
|
output frequency |
<= 20 kHz for fast output (PWM mode)
<= 100 kHz for fast output (PLS mode) <= 1 kHz for output |
|
accuracy |
+/- 0.1 % at 0.02...0.1 kHz for fast output
+/- 1 % at 0.1...1 kHz for fast output |
|
leakage current |
<= 5 µA for output
|
|
voltage drop |
<= 1 V
|
|
tungsten load |
<= 2.4 W
|
|
protection type |
Short-circuit and overload protection with automatic reset
Reverse polarity protection for fast output Short-circuit protection |
|
reset time |
10 ms automatic reset output
12 s automatic reset fast output |
|
memory capacity |
8 MB for program
64 MB for system memory RAM |
|
data backed up |
128 MB built-in flash memory for backup of user programs
|
|
data storage equipment |
<= 16 GB SD card optional
|
|
battery type |
BR2032 lithium non-rechargeable, battery life: 4 yr
|
|
backup time |
2 years at 25 °C
|
|
execution time for 1 KInstruction |
0.3 ms for event and periodic task
0.7 ms for other instruction |
|
application structure |
4 cyclic master tasks
8 event tasks 8 external event tasks 3 cyclic master tasks + 1 freewheeling task |
|
realtime clock |
With
|
|
clock drift |
<= 60 s/month at 25 °C
|
|
positioning functions |
PTO function 4 channel(s) (positioning frequency: 100 kHz)
PTO function 4 channel(s) for transistor output (positioning frequency: 1 kHz) |
|
counting input number |
4 fast input (HSC mode) at 200 kHz
14 standard input at 1 kHz |
|
control signal type |
A/B signal at 100 kHz for fast input (HSC mode)
Pulse/direction signal at 200 kHz for fast input (HSC mode) Single phase signal at 200 kHz for fast input (HSC mode) |
|
integrated connection type |
USB port with connector mini B USB 2.0
Ethernet with connector RJ45 Non isolated serial link "serial 1" with connector RJ45 and interface RS232/RS485 Non isolated serial link "serial 2" with connector removable screw terminal block and interface RS485 CANopen J1939 with connector male SUB-D 9 |
|
supply |
Serial link supply "serial 1" at 5 V, <= 200 mA
|
|
transmission rate |
1.2...115.2 kbit/s (115.2 kbit/s by default) for bus length of
15 m - communication protocol: RS485
1.2...115.2 kbit/s (115.2 kbit/s by default) for bus length of 3 m - communication protocol: RS232 480 Mbit/s for bus length of 3 m - communication protocol: USB 10/100 Mbit/s - communication protocol: Ethernet 1000 kbit/s for bus length of 20 m - communication protocol: CANopen 800 kbit/s for bus length of 40 m - communication protocol: CANopen 500 kbit/s for bus length of 100 m - communication protocol: CANopen 250 kbit/s for bus length of 250 m - communication protocol: CANopen 125 kbit/s for bus length of 500 m - communication protocol: CANopen 50 kbit/s for bus length of 1000 m - communication protocol: CANopen 20 kbit/s for bus length of 2500 m - communication protocol: CANopen |
|
communication port protocol |
Modbus non isolated serial link with master/slave method
|
|
port Ethernet |
1 - 10BASE-T/100BASE-TX port with copper cable support
|
|
ethernet services |
Ethernet/IP adapter
DHCP client IEC VAR ACCESS Modbus TCP client Modbus TCP server Modbus TCP slave device SNMP client/server FTP client/server SQL client Send and receive email from the controller based on TCP/UDP library Web server (WebVisu & XWeb system) OPC UA server DNS client |
|
local signalling |
1 LED green for SD card access (SD)
1 LED red for BAT 1 LED green for SL1 1 LED green for SL2 1 LED per channel green for I/O state 1 LED red for I/O error (I/O) 1 LED red for bus fault on TM4 (TM4) 1 LED green for Ethernet port activity 1 LED green for CANopen run 1 LED green for CANopen error 1 LED red for module error (ERR) 1 LED green for PWR 1 LED green for RUN |
|
electrical connection |
Removable screw terminal block for inputs and outputs (pitch
5.08 mm)
Removable screw terminal block for connecting the 24 V DC power supply (pitch 5.08 mm) |
|
cable distance between devices |
Unshielded cable: <= 50 m for input
Shielded cable: <= 10 m for fast input Unshielded cable: <= 50 m for output Shielded cable: <= 3 m for fast output |
|
insulation |
500 V AC between fast input and internal logic
Non-insulated between inputs 500 V AC between output and internal logic 500 V AC between fast output and internal logic Non-insulated between outputs 500 V AC between input and internal logic 500 V AC between supply and internal logic Non-insulated between supply and ground |
|
marking |
CE
|
|
surge withstand |
1 kV for power lines (DC) in common mode conforming to EN/IEC
61000-4-5
1 kV for shielded cable in common mode conforming to EN/IEC 61000-4-5 0.5 kV for power lines (DC) in differential mode conforming to EN/IEC 61000-4-5 1 kV for relay output in differential mode conforming to EN/IEC 61000-4-5 1 kV for input in common mode conforming to EN/IEC 61000-4-5 1 kV for transistor output in common mode conforming to EN/IEC 61000-4-5 |
|
web services |
Web server
|
|
maximum number of connections |
16 connection(s) for Ethernet/IP device
8 connection(s) for Modbus server |
|
CANopen feature profile |
DS 301 V4.02
DR 303-1 |
|
number of slave |
63 CANopen
|
|
mounting support |
Top hat type TH35-15 rail conforming to IEC 60715
Top hat type TH35-7.5 rail conforming to IEC 60715 Plate or panel with fixing kit |
|
height |
90 mm
|
|
depth |
95 mm
|
|
width |
150 mm
|
|
product weight |
0.53 kg
|
standards |
CSA C22.2 No 142
ANSI/ISA 12-12-01 UL 1604 CSA C22.2 No 213 EN/IEC 61131-2 : 2007 Marine specification (LR, ABS, DNV, GL) UL 508 |
|
---|---|---|
product certifications |
cULus
RCM IACS E10 CSA |
|
resistance to electrostatic discharge |
4 kV on contact conforming to EN/IEC 61000-4-2
8 kV in air conforming to EN/IEC 61000-4-2 |
|
resistance to electromagnetic fields |
10 V/m (80 MHz...1 GHz) conforming to EN/IEC 61000-4-3
3 V/m (1.4 GHz...2 GHz) conforming to EN/IEC 61000-4-3 1 V/m (2 GHz...3 GHz) conforming to EN/IEC 61000-4-3 |
|
resistance to fast transients |
2 kV for power lines conforming to EN/IEC 61000-4-4
1 kV for Ethernet line conforming to EN/IEC 61000-4-4 1 kV for serial link conforming to EN/IEC 61000-4-4 1 kV for input conforming to EN/IEC 61000-4-4 1 kV for transistor output conforming to EN/IEC 61000-4-4 |
|
resistance to conducted disturbances |
10 V (0.15...80 MHz) conforming to EN/IEC 61000-4-6
3 V (0.1...80 MHz) conforming to Marine specification (LR, ABS, DNV, GL) 10 V (spot frequency (2, 3, 4, 6.2, 8.2, 12.6, 16.5, 18.8, 22, 25 MHz)) conforming to Marine specification (LR, ABS, DNV, GL) |
|
electromagnetic emission |
Conducted emissions, test level: 120...69 dBµV/m QP, condition
of test: power lines (radio frequency: 10...150 kHz) conforming
to EN/IEC 55011
Conducted emissions, test level: 63 dBμV/m QP, condition of test: power lines (radio frequency: 1.5...30 MHz) conforming to EN/IEC 55011 Radiated emissions, test level: 40 dBμV/m QP with class A (radio frequency: 30...230 MHz) conforming to EN/IEC 55011 Conducted emissions, test level: 79...63 dBμV/m QP, condition of test: power lines (radio frequency: 150...1500 kHz) conforming to EN/IEC 55011 Radiated emissions, test level: 47 dBμV/m QP with class A (radio frequency: 230...1000 MHz) conforming to EN/IEC 55011 |
|
immunity to microbreaks |
10 ms
|
|
ambient air temperature for operation |
-10...55 °C for horizontal installation
-10...50 °C for vertical installation |
|
ambient air temperature for storage |
-25...70 °C
|
|
relative humidity |
10...95 % without condensation in operation
10...95 % without condensation in storage |
|
IP degree of protection |
IP20 with protective cover in place
|
|
pollution degree |
2
|
|
operating altitude |
0...2000 m
|
|
storage altitude |
0...3000 m
|
|
vibration resistance |
3.5 mm (vibration frequency: 5...8.4 Hz) on symmetrical rail
3 gn (vibration frequency: 8.4...150 Hz) on symmetrical rail 3.5 mm (vibration frequency: 5...8.4 Hz) on panel mounting 3 gn (vibration frequency: 8.4...150 Hz) on panel mounting |
|
shock resistance |
15 gn for 11 ms
|