Schneider TM241CEC24U Controller - M241 24 IO Transistor NPN Ethernet CAN Master
Enhance your automation systems with the Schneider TM241CEC24U Controller, a robust solution designed for sophisticated control applications. This state-of-the-art M241 controller is engineered to provide exceptional performance and reliability for industrial environments.
Key Features:
24 Digital Inputs/Outputs: The TM241CEC24U is equipped with 24 transistor NPN I/O points, offering flexible and high-speed control capabilities. Each I/O channel ensures rapid response times and precise signal processing, critical for demanding automation tasks.
Integrated Ethernet Port: Seamlessly integrate your automation system with the built-in Ethernet port. This feature facilitates high-speed communication, network integration, and remote management, optimizing operational efficiency and system connectivity.
CAN Bus Master Capability: The controller includes a CAN (Controller Area Network) master interface, enabling reliable and deterministic communication with other CAN-compatible devices. This functionality supports complex automation setups and enhances system coordination.
Scalable and Modular Design: The M241 series is designed with scalability in mind. The TM241CEC24U can be easily integrated into larger systems and expanded with additional modules, providing flexibility to adapt to evolving automation needs.
Advanced Programming and Diagnostics: The controller supports advanced programming features and diagnostics through Schneider Electric’s EcoStruxure™ Machine Expert software. This user-friendly environment allows for intuitive programming, configuration, and troubleshooting, streamlining development and maintenance processes.
Robust Industrial Standards: Built to withstand harsh industrial conditions, the TM241CEC24U adheres to stringent standards for durability and reliability. Its rugged construction ensures consistent performance even in challenging environments.
Applications:
Manufacturing Automation: Ideal for controlling machinery, assembly lines, and production processes, the TM241CEC24U delivers precise and reliable operation, ensuring optimal performance and productivity.
Process Control: The controller’s advanced features and I/O capabilities make it suitable for complex process control applications, providing accurate monitoring and management of industrial processes.
Building Automation: Leverage the Ethernet and CAN connectivity for integrating building management systems, including HVAC, lighting, and security systems, ensuring efficient and coordinated operations.
Specifications:
- I/O Type: 24 Transistor NPN
- Ethernet Port: Yes
- CAN Interface: Master
- Programming Software: EcoStruxure™ Machine Expert
- Operating Temperature Range: [Insert specific temperature range]
- Mounting: DIN Rail
Why Choose Schneider TM241CEC24U?
The Schneider TM241CEC24U Controller stands out with its high-speed I/O capabilities, seamless network integration, and robust design. It is an ideal choice for professionals seeking a reliable and versatile controller to meet the demands of modern industrial automation.
Optimize your automation solutions with the Schneider TM241CEC24U Controller. Contact us today to learn more about how this advanced controller can elevate your system performance.
range of product |
Modicon M241
|
|
---|---|---|
product or component type |
Logic controller
|
|
[Us] rated supply voltage |
24 V DC
|
|
discrete input number |
14 discrete input including 8 fast input conforming to IEC
61131-2 Type 1
|
|
discrete output type |
Transistor
|
|
discrete output number |
10 transistor including 4 fast output
|
|
discrete output voltage |
24 V DC for transistor output
|
|
discrete output current |
0.5 A with Q0...Q9 terminal(s) for transistor output
0.1 A with Q0...Q3 terminal(s) for fast output (PTO mode) |
discrete I/O number |
24
|
|
---|---|---|
number of I/O expansion module |
7 (local I/O architecture)
14 (remote I/O architecture) |
|
supply voltage limits |
20.4...28.8 V
|
|
inrush current |
50 A
|
|
power consumption in W |
32.6...40.4 W with max number of I/O expansion module
|
|
discrete input logic |
Sink or source
|
|
discrete input voltage |
24 V
|
|
discrete input voltage type |
DC
|
|
voltage state 1 guaranteed |
>= 15 V for input
|
|
voltage state 0 guaranteed |
<= 5 V for input
|
|
discrete input current |
5 mA for input
10.7 mA for fast input |
|
input impedance |
4.7 kOhm for input
2.81 kOhm for fast input |
|
response time |
50 µs turn-on operation with I0...I13 terminal(s) for input
50 µs turn-off operation with I0...I13 terminal(s) for input <= 2 µs turn-on operation with I0...I7 terminal(s) for fast input <= 2 µs turn-off operation with I0...I7 terminal(s) for fast input <= 34 µs turn-on operation with Q0...Q9 terminal(s) for output <= 250 µs turn-off operation with Q0...Q9 terminal(s) for output <= 2 µs turn-on operation with Q0...Q3 terminal(s) for fast output <= 2 µs turn-off operation with Q0...Q3 terminal(s) for fast output |
|
configurable filtering time |
1 µs for fast input
12 ms for fast input 0 ms for input 1 ms for input 4 ms for input 12 ms for input |
|
discrete output logic |
Negative logic (sink)
|
|
output voltage limits |
30 V DC
|
|
current per output common |
<= 2 A with Q0...Q3 terminal for fast output
<= 2 A with Q4...Q7 terminal for output <= 1 A with Q8...Q9 terminal for output |
|
output frequency |
<= 20 kHz for fast output (PWM mode)
<= 100 kHz for fast output (PLS mode) <= 1 kHz for output |
|
accuracy |
+/- 0.1 % at 0.02...0.1 kHz for fast output
+/- 1 % at 0.1...1 kHz for fast output |
|
leakage current |
<= 5 µA for output
|
|
voltage drop |
<= 1 V
|
|
tungsten load |
<= 2.4 W
|
|
protection type |
Short-circuit and overload protection with automatic reset
Reverse polarity protection for fast output Short-circuit protection |
|
reset time |
10 ms automatic reset output
12 s automatic reset fast output |
|
memory capacity |
8 MB for program
64 MB for system memory RAM |
|
data backed up |
128 MB built-in flash memory for backup of user programs
|
|
data storage equipment |
<= 16 GB SD card optional
|
|
battery type |
BR2032 lithium non-rechargeable, battery life: 4 yr
|
|
backup time |
2 years at 25 °C
|
|
execution time for 1 KInstruction |
0.3 ms for event and periodic task
0.7 ms for other instruction |
|
application structure |
8 external event tasks
3 cyclic master tasks + 1 freewheeling task 8 event tasks 4 cyclic master tasks |
|
realtime clock |
With
|
|
clock drift |
<= 60 s/month at 25 °C
|
|
positioning functions |
PTO function 4 channel(s) (positioning frequency: 100 kHz)
PTO function 4 channel(s) for transistor output (positioning frequency: 1 kHz) |
|
counting input number |
4 fast input (HSC mode) at 200 kHz
14 standard input at 1 kHz |
|
control signal type |
A/B signal at 100 kHz for fast input (HSC mode)
Pulse/direction signal at 200 kHz for fast input (HSC mode) Single phase signal at 200 kHz for fast input (HSC mode) |
|
integrated connection type |
USB port with connector mini B USB 2.0
Ethernet with connector RJ45 Non isolated serial link "serial 1" with connector RJ45 and interface RS232/RS485 Non isolated serial link "serial 2" with connector removable screw terminal block and interface RS485 CANopen J1939 with connector male SUB-D 9 |
|
supply |
Serial link supply "serial 1" at 5 V, <= 200 mA
|
|
transmission rate |
1.2...115.2 kbit/s (115.2 kbit/s by default) for bus length of
15 m - communication protocol: RS485
1.2...115.2 kbit/s (115.2 kbit/s by default) for bus length of 3 m - communication protocol: RS232 480 Mbit/s for bus length of 3 m - communication protocol: USB 10/100 Mbit/s - communication protocol: Ethernet 1000 kbit/s for bus length of 20 m - communication protocol: CANopen 800 kbit/s for bus length of 40 m - communication protocol: CANopen 500 kbit/s for bus length of 100 m - communication protocol: CANopen 250 kbit/s for bus length of 250 m - communication protocol: CANopen 125 kbit/s for bus length of 500 m - communication protocol: CANopen 50 kbit/s for bus length of 1000 m - communication protocol: CANopen 20 kbit/s for bus length of 2500 m - communication protocol: CANopen |
|
communication port protocol |
Modbus non isolated serial link with master/slave method
|
|
port Ethernet |
1 - 10BASE-T/100BASE-TX port with copper cable support
|
|
ethernet services |
Ethernet/IP adapter
DHCP client IEC VAR ACCESS Modbus TCP client Modbus TCP server Modbus TCP slave device SNMP client/server FTP client/server SQL client Send and receive email from the controller based on TCP/UDP library Web server (WebVisu & XWeb system) OPC UA server DNS client |
|
local signalling |
1 LED green for SD card access (SD)
1 LED red for BAT 1 LED green for SL1 1 LED green for SL2 1 LED per channel green for I/O state 1 LED red for I/O error (I/O) 1 LED red for bus fault on TM4 (TM4) 1 LED green for Ethernet port activity 1 LED green for CANopen run 1 LED green for CANopen error 1 LED red for module error (ERR) 1 LED green for PWR 1 LED green for RUN |
|
electrical connection |
Removable screw terminal block for inputs and outputs (pitch
5.08 mm)
Removable screw terminal block for connecting the 24 V DC power supply (pitch 5.08 mm) |
|
cable distance between devices |
Unshielded cable: <= 50 m for input
Shielded cable: <= 10 m for fast input Unshielded cable: <= 50 m for output Shielded cable: <= 3 m for fast output |
|
insulation |
500 V AC between fast input and internal logic
Non-insulated between inputs 500 V AC between output and internal logic 500 V AC between fast output and internal logic Non-insulated between outputs 500 V AC between input and internal logic 500 V AC between supply and internal logic Non-insulated between supply and ground |
|
marking |
CE
|
|
surge withstand |
1 kV for power lines (DC) in common mode conforming to EN/IEC
61000-4-5
1 kV for shielded cable in common mode conforming to EN/IEC 61000-4-5 0.5 kV for power lines (DC) in differential mode conforming to EN/IEC 61000-4-5 1 kV for relay output in differential mode conforming to EN/IEC 61000-4-5 1 kV for input in common mode conforming to EN/IEC 61000-4-5 1 kV for transistor output in common mode conforming to EN/IEC 61000-4-5 |
|
web services |
Web server
|
|
maximum number of connections |
16 connection(s) for Ethernet/IP device
8 connection(s) for Modbus server |
|
CANopen feature profile |
DS 301 V4.02
DR 303-1 |
|
number of slave |
63 CANopen
|
|
mounting support |
Top hat type TH35-15 rail conforming to IEC 60715
Top hat type TH35-7.5 rail conforming to IEC 60715 Plate or panel with fixing kit |
|
height |
90 mm
|
|
depth |
95 mm
|
|
width |
150 mm
|
|
product weight |
0.53 kg
|
standards |
CSA C22.2 No 142
ANSI/ISA 12-12-01 UL 1604 CSA C22.2 No 213 EN/IEC 61131-2 : 2007 Marine specification (LR, ABS, DNV, GL) UL 508 |
|
---|---|---|
product certifications |
CSA
IACS E10 RCM cULus |
|
resistance to electrostatic discharge |
4 kV on contact conforming to EN/IEC 61000-4-2
8 kV in air conforming to EN/IEC 61000-4-2 |
|
resistance to electromagnetic fields |
10 V/m (80 MHz...1 GHz) conforming to EN/IEC 61000-4-3
3 V/m (1.4 GHz...2 GHz) conforming to EN/IEC 61000-4-3 1 V/m (2 GHz...3 GHz) conforming to EN/IEC 61000-4-3 |
|
resistance to fast transients |
2 kV for power lines conforming to EN/IEC 61000-4-4
1 kV for Ethernet line conforming to EN/IEC 61000-4-4 1 kV for serial link conforming to EN/IEC 61000-4-4 1 kV for input conforming to EN/IEC 61000-4-4 1 kV for transistor output conforming to EN/IEC 61000-4-4 |
|
resistance to conducted disturbances |
10 V (0.15...80 MHz) conforming to EN/IEC 61000-4-6
3 V (0.1...80 MHz) conforming to Marine specification (LR, ABS, DNV, GL) 10 V (spot frequency (2, 3, 4, 6.2, 8.2, 12.6, 16.5, 18.8, 22, 25 MHz)) conforming to Marine specification (LR, ABS, DNV, GL) |
|
electromagnetic emission |
Conducted emissions, test level: 120...69 dBµV/m QP, condition
of test: power lines (radio frequency: 10...150 kHz) conforming
to EN/IEC 55011
Conducted emissions, test level: 63 dBμV/m QP, condition of test: power lines (radio frequency: 1.5...30 MHz) conforming to EN/IEC 55011 Radiated emissions, test level: 40 dBμV/m QP with class A (radio frequency: 30...230 MHz) conforming to EN/IEC 55011 Conducted emissions, test level: 79...63 dBμV/m QP, condition of test: power lines (radio frequency: 150...1500 kHz) conforming to EN/IEC 55011 Radiated emissions, test level: 47 dBμV/m QP with class A (radio frequency: 230...1000 MHz) conforming to EN/IEC 55011 |
|
immunity to microbreaks |
10 ms
|
|
ambient air temperature for operation |
-10...55 °C for horizontal installation
-10...50 °C for vertical installation |
|
ambient air temperature for storage |
-25...70 °C
|
|
relative humidity |
10...95 % without condensation in operation
10...95 % without condensation in storage |
|
IP degree of protection |
IP20 with protective cover in place
|
|
pollution degree |
2
|
|
operating altitude |
0...2000 m
|
|
storage altitude |
0...3000 m
|
|
vibration resistance |
3.5 mm (vibration frequency: 5...8.4 Hz) on symmetrical rail
3 gn (vibration frequency: 8.4...150 Hz) on symmetrical rail 3.5 mm (vibration frequency: 5...8.4 Hz) on panel mounting 3 gn (vibration frequency: 8.4...150 Hz) on panel mounting |
|
shock resistance |
15 gn for 11 ms
|