Schneider TM3SAC5R Safety Module for PLC TM2xx: 1 Function, Cat 3, Screw Terminals
Overview: The Schneider TM3SAC5R Safety Module is a high-performance safety solution designed for use with the Schneider Electric TM2xx PLC series. This module provides advanced safety functions in compliance with Category 3 of the ISO 13849-1 safety standard, ensuring robust protection and reliability for industrial automation applications.
Key Features:
Single Function Safety Module: The TM3SAC5R is engineered to deliver a specific safety function, offering a streamlined solution for applications requiring precise and reliable safety controls.
Category 3 Safety Compliance: Adheres to the rigorous safety standards of Category 3, providing enhanced protection against hazardous conditions and reducing the risk of accidents in automated systems.
Screw Terminals for Secure Connections: Equipped with screw terminals, this module ensures secure and stable electrical connections, facilitating easy installation and maintenance in industrial environments.
Compatibility: Specifically designed for seamless integration with Schneider Electric’s TM2xx PLC series, ensuring a smooth setup and operation within your existing control system.
Robust Performance: The module’s design emphasizes durability and high performance, suitable for demanding industrial settings where safety and reliability are paramount.
Applications:
The Schneider TM3SAC5R Safety Module is ideal for various industrial automation applications, including:
Machine Safety Systems: Ensures compliance with safety regulations and protects operators from potential hazards.
Industrial Automation: Integrates effortlessly with PLC systems to enhance overall safety and control in automated processes.
Manufacturing Lines: Provides reliable safety functions for machinery and equipment, contributing to a safer working environment.
Technical Specifications:
- Function: Single Safety Function
- Safety Category: Cat 3 (ISO 13849-1)
- Connection Type: Screw Terminals
- PLC Compatibility: Schneider Electric TM2xx Series
Benefits:
Enhanced Safety: Complies with international safety standards to mitigate risks and enhance operator safety.
Ease of Installation: Screw terminals simplify wiring and connection, reducing installation time and effort.
Reliability: Designed to perform consistently in challenging industrial conditions, ensuring long-term safety and performance.
Why Choose Schneider TM3SAC5R?
The Schneider TM3SAC5R Safety Module is a critical component for achieving safety compliance and protecting personnel in industrial automation environments. Its adherence to Category 3 standards, combined with its easy-to-install screw terminals, makes it an exceptional choice for enhancing the safety and reliability of your automation systems.
For more information or to integrate the Schneider TM3SAC5R into your automation setup, contact our experts or visit our product page.
range of product |
Modicon TM3 Safety
|
|
---|---|---|
product or component type |
Safety module
|
|
device short name |
TM3SAC
|
|
safety module application |
For emergency stop and switch monitoring
|
|
function of module |
Emergency stop monitoring 1-channel wiring
Emergency stop monitoring 2-channel wiring Monitoring of a movable guard with 2 switches and automatic start |
|
safety level |
Can reach PL d/category 3 EN/ISO 13849-1:2008
Can reach PL d/category 3 EN/ISO 13849-2:2012 Can reach SILCL 2 EN/IEC 62061:2005 Can reach SIL 2 EN/IEC 61508:2010 |
safety reliability data |
DC = 95 % EN/ISO 13849-1
PFHd = 5E-9 1/h IEC 61508-1 1 operation/hour DC-13 24 V DC 4 A PFHd = 30E-9 1/h IEC 61508-1 60 operations/hour DC-13 24 V DC 1 A MTTFd = 500 years EN/ISO 13849-1 1 operation/hour DC-13 24 V DC 4 A MTTFd = 85 years EN/ISO 13849-1 60 operations/hour DC-13 24 V DC 1 A SFF = 95 % IEC 61508-1 HFT = 1 IEC 61508-1 Type = A IEC 61508-1 |
|
---|---|---|
synchronisation time between inputs |
Unlimited
|
|
connections - terminals |
Captive screw clamp terminals, removable terminal block 1 x
0.2...1 x 2.5 mm² flexible without cable end 13-14, 23-24, 33-34
Captive screw clamp terminals, removable terminal block 1 x 0.2...1 x 2.5 mm² solid without cable end 13-14, 23-24, 33-34 Captive screw clamp terminals, removable terminal block 1 x 0.25...1 x 2.5 mm² flexible with cable end, with bezel 13-14, 23-24, 33-34 Captive screw clamp terminals, removable terminal block 1 x 0.25...1 x 2.5 mm² flexible with cable end, without bezel 13-14, 23-24, 33-34 Captive screw clamp terminals, removable terminal block 2 x 0.2...2 x 1.5 mm² flexible without cable end 13-14, 23-24, 33-34 Captive screw clamp terminals, removable terminal block 2 x 0.2...2 x 1.5 mm² solid without cable end 13-14, 23-24, 33-34 Captive screw clamp terminals, removable terminal block 2 x 0.25...2 x 1 mm² flexible with cable end, without bezel 13-14, 23-24, 33-34 Captive screw clamp terminals, removable terminal block 2 x 0.5...2 x 1.5 mm² flexible with cable end, with double bezel 13-14, 23-24, 33-34 Captive screw clamp terminals, removable terminal block 1 x 0.14...1 x 1.5 mm² flexible without cable end other terminals Captive screw clamp terminals, removable terminal block 1 x 0.14...1 x 1.5 mm² solid without cable end other terminals Captive screw clamp terminals, removable terminal block 1 x 0.25...1 x 0.5 mm² flexible with cable end, with bezel other terminals Captive screw clamp terminals, removable terminal block 1 x 0.25...1 x 1.5 mm² flexible with cable end, without bezel other terminals Captive screw clamp terminals, removable terminal block 2 x 0.14...2 x 0.5 mm² flexible without cable end other terminals Captive screw clamp terminals, removable terminal block 2 x 0.14...2 x 0.75 mm² solid without cable end other terminals Captive screw clamp terminals, removable terminal block 2 x 0.25...2 x 0.34 mm² flexible with cable end, without bezel other terminals Captive screw clamp terminals, removable terminal block 2 x 0.5 mm² flexible with cable end, with double bezel other terminals |
|
output type |
Relay instantaneous opening 3 NO potential free
|
|
number of safety circuits |
3 NO (relay instantaneous opening)
|
|
maximum switching voltage |
230 V utilisation category AC-15 at 50 Hz (relay instantaneous
opening)
24 V utilisation category DC-13 (relay instantaneous opening) |
|
[Us] rated supply voltage |
24 V DC - 15...20 %
|
|
power consumption in W |
0.2 W 5 V DC
3.6 W 24 V DC |
|
input protection type |
Internal, electronic
|
|
[Uc] control circuit voltage |
24 V DC
|
|
cable distance between devices |
30 m
|
|
breaking capacity |
360 VA holding AC-15 B300 relay output
3600 VA inrush AC-15 B300 relay output |
|
breaking capacity |
4 A 24 V 50 ms DC-13 relay output
|
|
output thermal current |
6 A per relay relay output
|
|
[Ith] conventional free air thermal current |
18 A
|
|
associated fuse rating |
4 A gG or gL relay output EN/IEC 60947-5-1
6 A fast blow relay output EN/IEC 60947-5-1 |
|
minimum output current |
10 mA relay output
|
|
output voltage |
10 V relay output
|
|
response time on input open |
<= 40 ms
|
|
[Ui] rated insulation voltage |
300 V 2 IEC 60647-5-1
|
|
[Uimp] rated impulse withstand voltage |
4 kV III IEC 60647-5-1
|
|
current consumption |
100 mA 24 V DC external supply at state on
|
|
local signalling |
6 LEDs green/red user
|
|
electrical connection |
Screw terminal
|
|
standards |
EN/ISO 13849-1:2008
EN/ISO 13849-2:2012 EN/IEC 62061:2005 EN/IEC 61508:2010 EN/IEC 60947-5-1:2010 EN/IEC 61131-2:2007 EN/IEC 60204-1:2005 EN/IEC 60204-1:2009/A1 IEC 61010-1:2010 EN 50581:2012 |
|
product certifications |
UL 61010-2-201
CSA Haz Loc Class 1 Division 2 (pending) TÜV RCM ANSI Haz Loc Class 1 Division 2 (pending) EAC CSA 61010-2-201 (pending) |
|
marking |
CE
UL TÜV EFUP 10 CSA REACH EAC RCM |
|
electromagnetic compatibility |
Electrostatic discharge immunity test 8 kV air discharge
conforming to EN/IEC 61000-4-2
Electrostatic discharge immunity test 6 kV contact discharge conforming to EN/IEC 61000-4-2 Susceptibility to electromagnetic fields 10 V/m 80 MHz to 1 GHz conforming to EN/IEC 61000-4-3 Susceptibility to electromagnetic fields 3 V/m 1.4 GHz...2 GHz conforming to EN/IEC 61000-4-3 Susceptibility to electromagnetic fields 1 V/m 2 GHz...3 GHz conforming to EN/IEC 61000-4-3 Magnetic field at power frequency 30 A/m 50...60 Hz conforming to EN/IEC 61000-4-8 Electrical fast transient/burst immunity test 3 kV power lines (DC) conforming to EN/IEC 61000-4-4 Electrical fast transient/burst immunity test 2 kV I/O conforming to EN/IEC 61000-4-4 1.2/50 µs shock waves immunity test 1 kV power lines (DC) conforming to EN/IEC 61000-4-5 Conducted RF disturbances 10 V 0.15...80 MHz conforming to EN/IEC 61000-4-6 Radiated emission 40 dBµV/m class A 24 V conforming to EN 55011 Radiated emission 47 dBµV/m class A 24 V conforming to EN 55011 |
|
mounting support |
Wall mount using attached fasteners
Rail top hat type TH35-7.5 IEC 60715 Rail top hat type TH35-15 IEC 60715 |
|
height |
94 mm
|
|
depth |
73 mm
|
|
width |
43.7 mm
|
|
product weight |
0.19 kg
|
standards |
EN 60204-1
EN/IEC 60947-5-1 EN/ISO 13850 EN 1088/ISO 14119 EN/IEC 60947-1 |
|
---|---|---|
resistance to electrostatic discharge |
6 kV on contact EN/IEC 61000-4-2
8 kV in air EN/IEC 61000-4-2 |
|
resistance to electromagnetic fields |
10 V/m 80 MHz...1 GHz EN/IEC 61000-4-3
3 V/m 1.4 GHz...2 GHz EN/IEC 61000-4-3 1 V/m 2 GHz...3 GHz EN/IEC 61000-4-3 |
|
resistance to magnetic fields |
30 A/m 50/60 Hz conforming to EN/IEC 61000-4-8
|
|
resistance to fast transients |
3 kV power lines (DC) EN/IEC 61000-4-4 DC
2 kV I/O lines EN/IEC 61000-4-4 |
|
surge withstand |
1 kV power lines (DC) differential mode EN/IEC 61000-4-5 DC
1 kV power lines (DC) common mode EN/IEC 61000-4-5 DC |
|
resistance to conducted disturbances |
10 V 0.15...80 MHz EN/IEC 61000-4-6
|
|
electromagnetic emission |
Radiated emissions 50 dBµV/m class A 24 V DC 30...230 Hz IEC
61131-3
Radiated emissions 57 dBµV/m class A 24 V DC 230...1000 Hz IEC 61131-3 |
|
ambient air temperature for operation |
-10...55 °C horizontal installation
|
|
ambient air temperature for storage |
-25...70 °C
|
|
relative humidity |
10...95 % without condensation in operation
10...95 % without condensation in storage |
|
IP degree of protection |
IP20 EN/IEC 60529 terminals
|
|
pollution degree |
2
|
|
operating altitude |
0...2000 m
|
|
storage altitude |
0...3000 m
|
|
vibration resistance |
+/- 3.5 mm 5...150 Hz IEC 60068-2-6
|
|
shock resistance |
15 gn 11 ms IEC 60068-2-27
|
|
mechanical robustness |
Bumps 6 ms 300 shocks 25 gn IEC 60068-2-27
|
Schneider TM3SAC5R Safety Module for PLC TM2xx - 1 Function, Cat 3, Screw Terminals
- Brand: Schneider
- Product Code: TM3SAC5R
- Availability: 1000
Tags: Schneider TM3SAC5R, Safety Module, PLC TM2xx, Cat 3, Screw Terminals, Industrial Safety, Schneider Electric, Automation Safety, Safety Control Module