• Schneider TM3SAC5RG Safety Module for PLC TM2xx - CAT3, Spring Terminals

Schneider TM3SAC5RG Safety Module for PLC TM2xx, 1 Function, CAT3, Spring Terminals

The Schneider TM3SAC5RG Safety Module stands as a testament to reliability and safety assurance within industrial automation. Engineered to complement the PLC TM2xx series, this module offers seamless integration and heightened safety functionality, ensuring a fortified operational environment.

Key Features:

  1. Purposeful Design: Specifically crafted to meet the stringent safety requirements of industrial settings, the TM3SAC5RG excels in delivering robust safety measures while maintaining operational efficacy.

  2. Single Function Precision: Focused on a singular function, this module excels in executing its designated safety protocol with precision, enhancing the safety integrity level within the automation system.

  3. CAT3 Compliance: Compliant with Category 3 safety standards, this module adheres to the highest safety levels, mitigating risks and potential hazards to ensure personnel and machinery safety.

  4. Efficient Spring Terminals: Incorporating advanced spring terminals, installation and maintenance become hassle-free, ensuring a reliable and secure connection for consistent performance.

Technical Specifications:

  • Compatibility: Designed to seamlessly integrate with the PLC TM2xx series, ensuring a streamlined setup.
  • Safety Function: Implements a specialized safety function aimed at mitigating risks and enhancing operational safety.
  • CAT Rating: Complies with CAT3 standards, offering heightened safety assurance.
  • Terminal Type: Equipped with spring terminals for efficient and secure connectivity.
  • Durable Build: Crafted with durable materials to withstand industrial conditions and ensure long-term reliability.
  • Compact Form Factor: Space-efficient design for easy installation within existing setups.

Applications:

Ideal for a spectrum of industrial applications including but not limited to manufacturing, assembly lines, and process control systems. The TM3SAC5RG serves as a vital component in ensuring a secure and reliable automation infrastructure, safeguarding both machinery and personnel.

Why Choose Schneider TM3SAC5RG Safety Module?

  • Reliability: Engineered by Schneider, a renowned name in industrial automation, ensuring top-notch quality and reliability.
  • Safety Priority: Prioritizes safety with precision-engineered safety protocols and CAT3 compliance.
  • Seamless Integration: Designed for compatibility with the PLC TM2xx series, ensuring effortless integration and operation.

Enhance your industrial automation setup with the Schneider TM3SAC5RG Safety Module, where safety meets precision, reliability, and seamless integration.

Main
range of product
Modicon TM3 Safety
product or component type
Safety module
device short name
TM3SAC
safety module application
For emergency stop and switch monitoring
function of module
Emergency stop monitoring 1-channel wiring
Emergency stop monitoring 2-channel wiring
Monitoring of a movable guard with 2 switches and automatic start
safety level
Can reach PL d/category 3 EN/ISO 13849-1:2008
Can reach PL d/category 3 EN/ISO 13849-2:2012
Can reach SILCL 2 EN/IEC 62061:2005
Can reach SIL 2 EN/IEC 61508:2010
Complementary
safety reliability data
DC = 95 % EN/ISO 13849-1
SFF = 95 % IEC 61508-1
HFT = 1 IEC 61508-1
Type = A IEC 61508-1
PFHd = 5E-9 1/h IEC 61508-1
PFHd = 30E-9 1/h IEC 61508-1
MTTFd = 500 years EN/ISO 13849-1
MTTFd = 85 years EN/ISO 13849-1
synchronisation time between inputs
Unlimited
connections - terminals
Captive spring terminals, removable terminal block 1 x 0.2...1 x 2.5 mm² flexible without cable end 13-14, 23-24, 33-34
Captive spring terminals, removable terminal block 1 x 0.2...1 x 2.5 mm² solid without cable end 13-14, 23-24, 33-34
Captive spring terminals, removable terminal block 1 x 0.25...1 x 2.5 mm² flexible with cable end, with bezel 13-14, 23-24, 33-34
Captive spring terminals, removable terminal block 1 x 0.25...1 x 2.5 mm² flexible with cable end, without bezel 13-14, 23-24, 33-34
Captive spring terminals, removable terminal block 2 x 0.5...2 x 1.5 mm² flexible with cable end, with double bezel 13-14, 23-24, 33-34
Captive spring terminals, removable terminal block 1 x 0.14...1 x 1.5 mm² flexible without cable end other terminals
Captive spring terminals, removable terminal block 1 x 0.14...1 x 1.5 mm² solid without cable end other terminals
Captive spring terminals, removable terminal block 1 x 0.25...1 x 0.5 mm² flexible with cable end, with bezel other terminals
Captive spring terminals, removable terminal block 1 x 0.25...1 x 1.5 mm² flexible with cable end, without bezel other terminals
output type
Relay instantaneous opening 3 NO potential free
number of safety circuits
3 NO (relay instantaneous opening)
maximum switching voltage
230 V utilisation category AC-15 at 50 Hz (relay instantaneous opening)
24 V utilisation category DC-13 (relay instantaneous opening)
[Us] rated supply voltage
24 V DC - 15...20 %
power consumption in W
0.2 W 5 V DC
3.6 W 24 V DC
input protection type
Internal, electronic
[Uc] control circuit voltage
24 V DC
cable distance between devices
30 m
breaking capacity
360 VA holding AC-15 B300 relay output
3600 VA inrush AC-15 B300 relay output
breaking capacity
4 A 24 V 50 ms DC-13 relay output
output thermal current
6 A per relay relay output
[Ith] conventional free air thermal current
18 A
associated fuse rating
4 A gG or gL relay output EN/IEC 60947-5-1
6 A fast blow relay output EN/IEC 60947-5-1
minimum output current
10 mA relay output
output voltage
10 V relay output
response time on input open
<= 40 ms
[Ui] rated insulation voltage
300 V 2 IEC 60647-5-1
[Uimp] rated impulse withstand voltage
4 kV III IEC 60647-5-1
current consumption
100 mA 24 V DC external supply
local signalling
6 LEDs green/red user
electrical connection
Spring terminal
standards
EN/ISO 13849-1:2008
EN/ISO 13849-2:2012
EN/IEC 62061:2005
EN/IEC 61508:2010
EN/IEC 60947-5-1:2010
EN/IEC 61131-2:2007
EN/IEC 60204-1:2005
EN/IEC 60204-1:2009/A1
IEC 61010-1:2010
EN 50581:2012
product certifications
UL 61010-2-201
CSA 61010-2-201 (pending)
CSA Haz Loc Class 1 Division 2 (pending)
TÜV
RCM
ANSI Haz Loc Class 1 Division 2 (pending)
EAC
marking
CSA
REACH
CE
EAC
EFUP 10
RCM
TÜV
UL
electromagnetic compatibility
Electrostatic discharge immunity test 8 kV air discharge conforming to EN/IEC 61000-4-2
Electrostatic discharge immunity test 6 kV contact discharge conforming to EN/IEC 61000-4-2
Susceptibility to electromagnetic fields 10 V/m 80 MHz to 1 GHz conforming to EN/IEC 61000-4-3
Susceptibility to electromagnetic fields 3 V/m 1.4 GHz...2 GHz conforming to EN/IEC 61000-4-3
Susceptibility to electromagnetic fields 1 V/m 2 GHz...3 GHz conforming to EN/IEC 61000-4-3
Magnetic field at power frequency 30 A/m 50...60 Hz conforming to EN/IEC 61000-4-8
Electrical fast transient/burst immunity test 3 kV power lines (DC) conforming to EN/IEC 61000-4-4
Electrical fast transient/burst immunity test 2 kV I/O conforming to EN/IEC 61000-4-4
1.2/50 µs shock waves immunity test 1 kV power lines (DC) conforming to EN/IEC 61000-4-5
Conducted RF disturbances 10 V 0.15...80 MHz conforming to EN/IEC 61000-4-6
Radiated emission 40 dBµV/m class A 24 V conforming to EN 55011
Radiated emission 47 dBµV/m class A 24 V conforming to EN 55011
mounting support
Wall mount using attached fasteners
Rail top hat type TH35-7.5 IEC 60715
Rail top hat type TH35-15 IEC 60715
height
94 mm
depth
73 mm
width
43.7 mm
product weight
0.19 kg
Environment
standards
EN/IEC 60947-1
EN 1088/ISO 14119
EN/ISO 13850
EN/IEC 60947-5-1
EN 60204-1
resistance to electrostatic discharge
6 kV on contact EN/IEC 61000-4-2
8 kV in air EN/IEC 61000-4-2
resistance to electromagnetic fields
10 V/m 80 MHz...1 GHz EN/IEC 61000-4-3
3 V/m 1.4 GHz...2 GHz EN/IEC 61000-4-3
1 V/m 2 GHz...3 GHz EN/IEC 61000-4-3
resistance to magnetic fields
30 A/m 50/60 Hz conforming to EN/IEC 61000-4-8
resistance to fast transients
3 kV power lines (DC) EN/IEC 61000-4-4 DC
2 kV I/O lines EN/IEC 61000-4-4
surge withstand
1 kV power lines (DC) differential mode EN/IEC 61000-4-5 DC
1 kV power lines (DC) common mode EN/IEC 61000-4-5 DC
resistance to conducted disturbances
10 V 0.15...80 MHz EN/IEC 61000-4-6
electromagnetic emission
Radiated emissions 50 dBµV/m class A 24 V DC 30...230 Hz IEC 61131-3
Radiated emissions 57 dBµV/m class A 24 V DC 230...1000 Hz IEC 61131-3
ambient air temperature for operation
-10...55 °C horizontal installation
ambient air temperature for storage
-25...70 °C
relative humidity
10...95 % without condensation in operation
10...95 % without condensation in storage
IP degree of protection
IP20 EN/IEC 60529 terminals
pollution degree
2
operating altitude
0...2000 m
storage altitude
0...3000 m
vibration resistance
+/- 3.5 mm 5...150 Hz IEC 60068-2-6
shock resistance
15 gn 11 ms IEC 60068-2-27
mechanical robustness
Bumps 6 ms 300 shocks 25 gn IEC 60068-2-27

Schneider TM3SAC5RG Safety Module for PLC TM2xx - CAT3, Spring Terminals

  • Brand: Schneider
  • Product Code: TM3SAC5RG
  • Availability: 1000

Tags: Schneider TM3SAC5RG, Safety Module, PLC TM2xx, CAT3 Compliance, Spring Terminals