• Schneider TM3SAFL5R Safety Module for PLC TM2xx - 2 Functions, Category 3, Screw Terminals

Schneider TM3SAFL5R Safety Module for PLC TM2xx

Overview:

The Schneider TM3SAFL5R Safety Module is a high-performance safety solution designed for use with the Schneider TM2xx PLC series. This advanced safety module is engineered to provide reliable and robust safety functions to ensure the secure operation of automated machinery and processes. Adhering to the highest standards of safety and compliance, the TM3SAFL5R is ideal for applications requiring Category 3 safety functionality and precision control.

Key Features:

  • Functions: The TM3SAFL5R offers dual safety functions, providing enhanced flexibility and control in various safety applications. Its versatile functionality supports a wide range of safety requirements, making it a valuable component in complex safety systems.

  • Category 3 Compliance: This safety module conforms to Category 3 safety standards, ensuring high levels of protection and reliability. It is designed to meet rigorous safety requirements, reducing risks and enhancing overall system integrity.

  • Screw Terminals: Equipped with screw terminals for secure and reliable connections, the TM3SAFL5R facilitates straightforward wiring and installation. The screw terminal design ensures stable connections and minimizes the risk of loose or faulty wiring.

  • Compatibility: Specifically designed for integration with the Schneider TM2xx PLC series, the TM3SAFL5R seamlessly integrates into existing automation systems, providing an effective safety solution with minimal setup and configuration.

  • Robust Construction: Built to withstand demanding industrial environments, the TM3SAFL5R features a durable construction that ensures long-term performance and reliability. Its robust design is ideal for use in harsh conditions, contributing to the module's longevity and operational stability.

Applications:

The Schneider TM3SAFL5R Safety Module is suitable for a range of applications, including:

  • Industrial machinery and equipment
  • Automated production lines
  • Safety-critical systems requiring Category 3 compliance
  • Applications needing reliable and flexible safety functions

Technical Specifications:

  • Functionality: 2 safety functions
  • Safety Category: Category 3
  • Terminal Type: Screw terminals
  • Compatibility: Schneider TM2xx PLC series

Benefits:

  • Enhanced Safety: Provides high levels of safety compliance and protection for automated systems.
  • Flexible Integration: Easily integrates with Schneider TM2xx PLCs, offering versatile safety solutions.
  • Reliable Performance: Durable construction and secure screw terminals ensure consistent and reliable operation.

Conclusion:

The Schneider TM3SAFL5R Safety Module is an essential component for achieving high safety standards in automated systems. Its dual-function capability, Category 3 compliance, and secure screw terminals make it a reliable choice for enhancing safety and efficiency in industrial applications. Invest in the Schneider TM3SAFL5R for a robust, flexible, and reliable safety solution tailored to meet the demands of modern automation systems.

Main
range of product
Modicon TM3 Safety
product or component type
Safety module
device short name
TM3SAFL
safety module application
For emergency stop, switch and safety light curtain monitoring
function of module
Emergency stop monitoring 2-channel wiring
Monitoring of a movable guard
Multiple emergency stop monitoring 2-channel wiring
Monitoring of electro-sensitive protection equipment (ESPE) PNP/PNP
Proximity sensor monitoring PNP/PNP
Monitoring of a movable guard with 2 switches and automatic start
safety level
Can reach PL d/category 3 EN/ISO 13849-1:2008
Can reach PL d/category 3 EN/ISO 13849-2:2012
Can reach SILCL 2 EN/IEC 62061:2005
Can reach SIL 2 EN/IEC 61508:2010
Complementary
safety reliability data
DC = 95 % EN/ISO 13849-1
PFHd = 5E-9 1/h IEC 61508-1 1 operation/hour DC-13 24 V DC 4 A
PFHd = 30E-9 1/h IEC 61508-1 60 operations/hour DC-13 24 V DC 1 A
MTTFd = 500 years EN/ISO 13849-1 1 operation/hour DC-13 24 V DC 4 A
MTTFd = 85 years EN/ISO 13849-1 60 operations/hour DC-13 24 V DC 1 A
SFF = 95 % IEC 61508-1
HFT = 1 IEC 61508-1
Type = A IEC 61508-1
synchronisation time between inputs
Unlimited
connections - terminals
Captive screw clamp terminals, removable terminal block 1 x 0.2...1 x 2.5 mm² flexible without cable end 13-14, 23-24, 33-34
Captive screw clamp terminals, removable terminal block 1 x 0.2...1 x 2.5 mm² solid without cable end 13-14, 23-24, 33-34
Captive screw clamp terminals, removable terminal block 1 x 0.25...1 x 2.5 mm² flexible with cable end, with bezel 13-14, 23-24, 33-34
Captive screw clamp terminals, removable terminal block 1 x 0.25...1 x 2.5 mm² flexible with cable end, without bezel 13-14, 23-24, 33-34
Captive screw clamp terminals, removable terminal block 2 x 0.2...2 x 1.5 mm² flexible without cable end 13-14, 23-24, 33-34
Captive screw clamp terminals, removable terminal block 2 x 0.2...2 x 1.5 mm² solid without cable end 13-14, 23-24, 33-34
Captive screw clamp terminals, removable terminal block 2 x 0.25...2 x 1 mm² flexible with cable end, without bezel 13-14, 23-24, 33-34
Captive screw clamp terminals, removable terminal block 2 x 0.5...2 x 1.5 mm² flexible with cable end, with double bezel 13-14, 23-24, 33-34
Captive screw clamp terminals, removable terminal block 1 x 0.14...1 x 1.5 mm² flexible without cable end other terminals
Captive screw clamp terminals, removable terminal block 1 x 0.14...1 x 1.5 mm² solid without cable end other terminals
Captive screw clamp terminals, removable terminal block 1 x 0.25...1 x 0.5 mm² flexible with cable end, with bezel other terminals
Captive screw clamp terminals, removable terminal block 1 x 0.25...1 x 1.5 mm² flexible with cable end, without bezel other terminals
Captive screw clamp terminals, removable terminal block 2 x 0.14...2 x 0.5 mm² flexible without cable end other terminals
Captive screw clamp terminals, removable terminal block 2 x 0.14...2 x 0.75 mm² solid without cable end other terminals
Captive screw clamp terminals, removable terminal block 2 x 0.25...2 x 0.34 mm² flexible with cable end, without bezel other terminals
Captive screw clamp terminals, removable terminal block 2 x 0.5 mm² flexible with cable end, with double bezel other terminals
output type
Relay instantaneous opening 3 NO potential free
number of safety circuits
3 NO (relay instantaneous opening)
maximum switching voltage
230 V utilisation category AC-15 at 50 Hz (relay instantaneous opening)
24 V utilisation category DC-13 (relay instantaneous opening)
[Us] rated supply voltage
24 V DC - 15...20 %
power consumption in W
0.2 W 5 V DC
3.6 W 24 V DC
input protection type
Internal, electronic
[Uc] control circuit voltage
24 V DC
cable distance between devices
30 m
breaking capacity
360 VA holding AC-15 B300 relay output
3600 VA inrush AC-15 B300 relay output
breaking capacity
4 A 24 V 50 ms DC-13 relay output
output thermal current
6 A per relay relay output
[Ith] conventional free air thermal current
18 A
associated fuse rating
4 A gG or gL relay output EN/IEC 60947-5-1
6 A fast blow relay output EN/IEC 60947-5-1
minimum output current
10 mA relay output
output voltage
10 V relay output
response time on input open
<= 40 ms
[Ui] rated insulation voltage
300 V 2 IEC 60647-5-1
[Uimp] rated impulse withstand voltage
4 kV III IEC 60647-5-1
current consumption
100 mA 24 V DC external supply
local signalling
8 LEDs green/red user
electrical connection
Screw terminal
product compatibility
Safety light curtains EN/IEC 61496-1 (type 4)
standards
EN/ISO 13849-1:2008
EN/ISO 13849-2:2012
EN/IEC 62061:2005
EN/IEC 61508:2010
EN/IEC 60947-5-1:2010
EN/IEC 61131-2:2007
EN/IEC 60204-1:2005
EN/IEC 60204-1:2009/A1
IEC 61010-1:2010
EN 50581:2012
product certifications
UL 61010-2-201
TÜV
ANSI Haz Loc Class 1 Division 2 (pending)
CSA 61010-2-201 (pending)
CSA Haz Loc Class 1 Division 2 (pending)
RCM
EAC
marking
REACH
EAC
TÜV
EFUP 10
CE
UL
RCM
CSA
electromagnetic compatibility
Electrostatic discharge immunity test 8 kV air discharge conforming to EN/IEC 61000-4-2
Electrostatic discharge immunity test 6 kV contact discharge conforming to EN/IEC 61000-4-2
Susceptibility to electromagnetic fields 10 V/m 80 MHz to 1 GHz conforming to EN/IEC 61000-4-3
Susceptibility to electromagnetic fields 3 V/m 1.4 GHz...2 GHz conforming to EN/IEC 61000-4-3
Susceptibility to electromagnetic fields 1 V/m 2 GHz...3 GHz conforming to EN/IEC 61000-4-3
Magnetic field at power frequency 30 A/m 50...60 Hz conforming to EN/IEC 61000-4-8
Electrical fast transient/burst immunity test 3 kV power lines (DC) conforming to EN/IEC 61000-4-4
Electrical fast transient/burst immunity test 2 kV I/O conforming to EN/IEC 61000-4-4
1.2/50 µs shock waves immunity test 1 kV power lines (DC) conforming to EN/IEC 61000-4-5
Conducted RF disturbances 10 V 0.15...80 MHz conforming to EN/IEC 61000-4-6
Radiated emission 40 dBµV/m class A 24 V conforming to EN 55011
Radiated emission 47 dBµV/m class A 24 V conforming to EN 55011
mounting support
Wall mount using attached fasteners
Rail top hat type TH35-7.5 IEC 60715
Rail top hat type TH35-15 IEC 60715
height
94 mm
depth
73 mm
width
43.7 mm
product weight
0.19 kg

Environment
standards
EN 1088/ISO 14119
EN/ISO 13850
EN/IEC 60947-5-1
EN/IEC 60947-1
EN 60204-1
resistance to electrostatic discharge
6 kV on contact EN/IEC 61000-4-2
8 kV in air EN/IEC 61000-4-2
resistance to electromagnetic fields
10 V/m 80 MHz...1 GHz EN/IEC 61000-4-3
3 V/m 1.4 GHz...2 GHz EN/IEC 61000-4-3
1 V/m 2 GHz...3 GHz EN/IEC 61000-4-3
resistance to magnetic fields
30 A/m 50/60 Hz conforming to EN/IEC 61000-4-8
resistance to fast transients
3 kV power lines (DC) EN/IEC 61000-4-4 DC
2 kV I/O lines EN/IEC 61000-4-4
surge withstand
1 kV power lines (DC) differential mode EN/IEC 61000-4-5 DC
1 kV power lines (DC) common mode EN/IEC 61000-4-5 DC
resistance to conducted disturbances
10 V 0.15...80 MHz EN/IEC 61000-4-6
electromagnetic emission
Radiated emissions 50 dBµV/m class A 24 V DC 30...230 Hz IEC 61131-3
Radiated emissions 57 dBµV/m class A 24 V DC 230...1000 Hz IEC 61131-3
ambient air temperature for operation
-10...55 °C horizontal installation
ambient air temperature for storage
-25...70 °C
relative humidity
10...95 % without condensation in operation
10...95 % without condensation in storage
IP degree of protection
IP20 EN/IEC 60529 terminals
pollution degree
2
operating altitude
0...2000 m
storage altitude
0...3000 m
vibration resistance
+/- 3.5 mm 5...150 Hz IEC 60068-2-6
shock resistance
15 gn 11 ms IEC 60068-2-27
mechanical robustness
Bumps 6 ms 300 shocks 25 gn IEC 60068-2-27

Schneider TM3SAFL5R Safety Module for PLC TM2xx - 2 Functions, Category 3, Screw Terminals

  • Brand: Schneider
  • Product Code: TM3SAFL5R
  • Availability: 1000

Tags: Schneider TM3SAFL5R, Safety Module, PLC TM2xx, Category 3, 2 Functions, Screw Terminals, Industrial Automation, Safety Solutions, Schneider Electric, Automation Safety