Schneider TM3SAFL5RG Safety Module for PLC TM2xx, 2 Functions, CAT3, Spring Terminals
The Schneider TM3SAFL5RG Safety Module is meticulously engineered to bolster the safety features of PLC TM2xx systems, ensuring optimal functionality and security in industrial automation setups. This module stands out for its incorporation of advanced safety measures, offering two distinct functions within a singular, seamlessly integrated unit.
Key Features:
Enhanced Safety Functions: Designed to adhere to stringent safety norms, this module elevates the protection mechanisms within the PLC TM2xx system. It employs cutting-edge safety algorithms and protocols to guarantee a robust safety framework.
Dual Functionality: With the capability to execute two separate functions concurrently, this module maximizes operational efficiency without compromising safety. This versatility allows for diverse safety applications within the industrial environment.
CAT3 Compliance: Meeting Category 3 safety requirements, the TM3SAFL5RG ensures a reliable safety performance level in compliance with industry standards, mitigating risks effectively.
Spring Terminals: Equipped with spring terminals, the module facilitates effortless and secure connections, streamlining installation processes while ensuring a steadfast electrical connection.
Technical Specifications:
- Module Type: Safety Module
- Compatible with: PLC TM2xx Systems
- Functions: Dual functions for diverse safety applications
- Safety Category: CAT3 compliant
- Terminal Type: Spring Terminals for secure connections
- Robust Design: Engineered for durability and long-term reliability in industrial environments
Benefits:
- Enhanced Safety: Provides heightened safety measures within industrial automation settings, reducing potential risks and hazards.
- Versatility: Dual functionality enables the implementation of various safety protocols, catering to diverse operational needs.
- Efficient Installation: Spring terminals facilitate quick and secure connections, expediting installation processes.
- Compliance and Reliability: CAT3 compliance ensures adherence to safety standards, guaranteeing a reliable safety performance level.
For professionals seeking a safety module that meets CAT3 compliance standards and delivers dual functionality within the PLC TM2xx framework, the Schneider TM3SAFL5RG presents an optimal solution. Its robust design, advanced safety features, and efficient spring terminals make it a dependable choice for industrial safety applications.
range of product |
Modicon TM3 Safety
|
|
---|---|---|
product or component type |
Safety module
|
|
device short name |
TM3SAFL
|
|
safety module application |
For emergency stop, switch and safety light curtain monitoring
|
|
function of module |
Emergency stop monitoring 2-channel wiring
Monitoring of a movable guard Multiple emergency stop monitoring 2-channel wiring Monitoring of electro-sensitive protection equipment (ESPE) PNP/PNP Proximity sensor monitoring PNP/PNP Monitoring of a movable guard with 2 switches and automatic start |
|
safety level |
Can reach PL d/category 3 EN/ISO 13849-1:2008
Can reach PL d/category 3 EN/ISO 13849-2:2012 Can reach SILCL 2 EN/IEC 62061:2005 Can reach SIL 2 EN/IEC 61508:2010 |
safety reliability data |
DC = 95 % EN/ISO 13849-1
PFHd = 5E-9 1/h IEC 61508-1 1 operation/hour DC-13 24 V DC 4 A PFHd = 30E-9 1/h IEC 61508-1 60 operations/hour DC-13 24 V DC 1 A MTTFd = 500 years EN/ISO 13849-1 1 operation/hour DC-13 24 V DC 4 A MTTFd = 85 years EN/ISO 13849-1 60 operations/hour DC-13 24 V DC 1 A SFF = 95 % IEC 61508-1 HFT = 1 IEC 61508-1 Type = A IEC 61508-1 |
|
---|---|---|
synchronisation time between inputs |
Unlimited
|
|
connections - terminals |
Captive spring terminals, removable terminal block 1 x 0.2...1 x
2.5 mm² flexible without cable end 13-14, 23-24, 33-34
Captive spring terminals, removable terminal block 1 x 0.2...1 x 2.5 mm² solid without cable end 13-14, 23-24, 33-34 Captive spring terminals, removable terminal block 1 x 0.25...1 x 2.5 mm² flexible with cable end, with bezel 13-14, 23-24, 33-34 Captive spring terminals, removable terminal block 1 x 0.25...1 x 2.5 mm² flexible with cable end, without bezel 13-14, 23-24, 33-34 Captive spring terminals, removable terminal block 2 x 0.5...2 x 1.5 mm² flexible with cable end, with double bezel 13-14, 23-24, 33-34 Captive spring terminals, removable terminal block 1 x 0.14...1 x 1.5 mm² flexible without cable end other terminals Captive spring terminals, removable terminal block 1 x 0.14...1 x 1.5 mm² solid without cable end other terminals Captive spring terminals, removable terminal block 1 x 0.25...1 x 0.5 mm² flexible with cable end, with bezel other terminals Captive spring terminals, removable terminal block 1 x 0.25...1 x 1.5 mm² flexible with cable end, without bezel other terminals |
|
output type |
Relay instantaneous opening 3 NO potential free
|
|
number of safety circuits |
3 NO (relay instantaneous opening)
|
|
maximum switching voltage |
230 V utilisation category AC-15 at 50 Hz (relay instantaneous
opening)
24 V utilisation category DC-13 (relay instantaneous opening) |
|
[Us] rated supply voltage |
24 V DC - 15...20 %
|
|
power consumption in W |
0.2 W 5 V DC
3.6 W 24 V DC |
|
input protection type |
Internal, electronic
|
|
[Uc] control circuit voltage |
24 V DC
|
|
cable distance between devices |
30 m
|
|
breaking capacity |
360 VA holding AC-15 B300 relay output
3600 VA inrush AC-15 B300 relay output |
|
breaking capacity |
4 A 24 V 50 ms DC-13 relay output
|
|
output thermal current |
6 A per relay relay output
|
|
[Ith] conventional free air thermal current |
18 A
|
|
associated fuse rating |
4 A gG or gL relay output EN/IEC 60947-5-1
6 A fast blow relay output EN/IEC 60947-5-1 |
|
minimum output current |
10 mA relay output
|
|
output voltage |
10 V relay output
|
|
response time on input open |
<= 40 ms
|
|
[Ui] rated insulation voltage |
300 V 2 IEC 60647-5-1
|
|
[Uimp] rated impulse withstand voltage |
4 kV III IEC 60647-5-1
|
|
current consumption |
100 mA 24 V DC external supply
|
|
local signalling |
8 LEDs green/red user
|
|
electrical connection |
Spring terminal
|
|
product compatibility |
Safety light curtains EN/IEC 61496-1 (type 4)
|
|
standards |
EN/ISO 13849-1:2008
EN/ISO 13849-2:2012 EN/IEC 62061:2005 EN/IEC 61508:2010 EN/IEC 60947-5-1:2010 EN/IEC 61131-2:2007 EN/IEC 60204-1:2005 EN/IEC 60204-1:2009/A1 IEC 61010-1:2010 EN 50581:2012 |
|
product certifications |
RCM
CSA Haz Loc Class 1 Division 2 (pending) ANSI Haz Loc Class 1 Division 2 (pending) TÜV UL 61010-2-201 CSA 61010-2-201 (pending) EAC |
|
marking |
CSA
UL TÜV CE RCM EAC EFUP 10 REACH |
|
electromagnetic compatibility |
Electrostatic discharge immunity test 8 kV air discharge
conforming to EN/IEC 61000-4-2
Electrostatic discharge immunity test 6 kV contact discharge conforming to EN/IEC 61000-4-2 Susceptibility to electromagnetic fields 10 V/m 80 MHz to 1 GHz conforming to EN/IEC 61000-4-3 Susceptibility to electromagnetic fields 3 V/m 1.4 GHz...2 GHz conforming to EN/IEC 61000-4-3 Susceptibility to electromagnetic fields 1 V/m 2 GHz...3 GHz conforming to EN/IEC 61000-4-3 Magnetic field at power frequency 30 A/m 50...60 Hz conforming to EN/IEC 61000-4-8 Electrical fast transient/burst immunity test 3 kV power lines (DC) conforming to EN/IEC 61000-4-4 Electrical fast transient/burst immunity test 2 kV I/O conforming to EN/IEC 61000-4-4 1.2/50 µs shock waves immunity test 1 kV power lines (DC) conforming to EN/IEC 61000-4-5 Conducted RF disturbances 10 V 0.15...80 MHz conforming to EN/IEC 61000-4-6 Radiated emission 40 dBµV/m class A 24 V conforming to EN 55011 Radiated emission 47 dBµV/m class A 24 V conforming to EN 55011 |
|
mounting support |
Wall mount using attached fasteners
Rail top hat type TH35-7.5 IEC 60715 Rail top hat type TH35-15 IEC 60715 |
|
height |
94 mm
|
|
depth |
73 mm
|
|
width |
43.7 mm
|
|
product weight |
0.19 kg
|
standards |
EN 1088/ISO 14119
EN/IEC 60947-1 EN/IEC 60947-5-1 EN/ISO 13850 EN 60204-1 |
|
---|---|---|
resistance to electrostatic discharge |
6 kV on contact EN/IEC 61000-4-2
8 kV in air EN/IEC 61000-4-2 |
|
resistance to electromagnetic fields |
10 V/m 80 MHz...1 GHz EN/IEC 61000-4-3
3 V/m 1.4 GHz...2 GHz EN/IEC 61000-4-3 1 V/m 2 GHz...3 GHz EN/IEC 61000-4-3 |
|
resistance to magnetic fields |
30 A/m 50/60 Hz conforming to EN/IEC 61000-4-8
|
|
resistance to fast transients |
3 kV power lines (DC) EN/IEC 61000-4-4 DC
2 kV I/O lines EN/IEC 61000-4-4 |
|
surge withstand |
1 kV power lines (DC) differential mode EN/IEC 61000-4-5 DC
1 kV power lines (DC) common mode EN/IEC 61000-4-5 DC |
|
resistance to conducted disturbances |
10 V 0.15...80 MHz EN/IEC 61000-4-6
|
|
electromagnetic emission |
Radiated emissions 50 dBµV/m class A 24 V DC 30...230 Hz IEC
61131-3
Radiated emissions 57 dBµV/m class A 24 V DC 230...1000 Hz IEC 61131-3 |
|
ambient air temperature for operation |
-10...55 °C horizontal installation
|
|
ambient air temperature for storage |
-25...70 °C
|
|
relative humidity |
10...95 % without condensation in operation
10...95 % without condensation in storage |
|
IP degree of protection |
IP20 EN/IEC 60529 terminals
|
|
pollution degree |
2
|
|
operating altitude |
0...2000 m
|
|
storage altitude |
0...3000 m
|
|
vibration resistance |
+/- 3.5 mm 5...150 Hz IEC 60068-2-6
|
|
shock resistance |
15 gn 11 ms IEC 60068-2-27
|
|
mechanical robustness |
Bumps 6 ms 300 shocks 25 gn IEC 60068-2-27
|
Schneider TM3SAFL5RG Safety Module for PLC TM2xx - CAT3, Dual Functions, Spring Terminals
- Brand: Schneider
- Product Code: TM3SAFL5RG
- Availability: 1000