Schneider TM3SAK6RG Safety Module for PLC TM2xx Series
Overview: The Schneider TM3SAK6RG Safety Module is a high-performance safety component designed to integrate seamlessly with Schneider's TM2xx PLC series. This advanced safety module provides crucial safety functions, ensuring operational integrity and compliance with Category 4 safety standards. Ideal for complex automation systems, the TM3SAK6RG module is engineered to deliver robust performance and reliability in safety-critical applications.
Key Features:
Safety Functions: The TM3SAK6RG Safety Module supports three essential safety functions, including:
- Emergency Stop (E-Stop): Immediate and reliable shutdown of machinery in emergency situations.
- Safety Gate Monitoring: Ensures that safety gates or protective barriers are properly closed before machinery resumes operation.
- Muting Functions: Facilitates temporary bypass of safety functions for specific operations, maintaining safety without compromising productivity.
Category 4 Compliance: The module adheres to the highest safety standards, conforming to Category 4 of the ISO 13849-1 safety requirements. This ensures that the TM3SAK6RG provides maximum protection against potential hazards, minimizing risk and enhancing overall safety in industrial environments.
Spring Terminals: Equipped with spring-loaded terminals, the TM3SAK6RG facilitates secure and efficient wiring connections. The spring terminal design simplifies installation and maintenance, reducing wiring time and ensuring a stable electrical connection.
Compatibility: Specifically designed for use with the Schneider TM2xx PLC series, the TM3SAK6RG integrates effortlessly into existing systems. Its compatibility ensures a streamlined installation process and seamless operation with other Schneider automation components.
Robust Design: The TM3SAK6RG features a rugged and compact design, making it suitable for use in demanding industrial environments. Its durable construction is engineered to withstand harsh conditions and maintain optimal performance over time.
Easy Integration: The module supports straightforward configuration and integration with Schneider's PLC programming tools. Its user-friendly interface and documentation facilitate quick setup and programming, minimizing downtime and accelerating project deployment.
Applications: The Schneider TM3SAK6RG Safety Module is ideal for a wide range of industrial automation applications, including:
- Manufacturing: Enhancing safety in production lines and machinery.
- Processing: Ensuring secure operation in processing environments.
- Material Handling: Protecting operators and equipment in material handling systems.
Technical Specifications:
- Functionality: 3 safety functions
- Safety Category: Category 4 (ISO 13849-1)
- Connection Type: Spring terminals
- Compatibility: Schneider TM2xx PLC series
Conclusion: The Schneider TM3SAK6RG Safety Module represents a crucial component in ensuring safety and compliance in industrial automation systems. With its advanced safety functions, Category 4 compliance, and user-friendly design, this module delivers exceptional performance and reliability for a wide range of applications. Integrate the TM3SAK6RG into your PLC system to enhance safety and operational efficiency.
range of product |
Modicon TM3 Safety
|
|
---|---|---|
product or component type |
Safety module
|
|
device short name |
TM3SAK
|
|
safety module application |
For emergency stop, switch, sensing mat/edges or safety light
curtain monitoring
|
|
function of module |
Emergency stop monitoring 1-channel wiring
Emergency stop monitoring 2-channel wiring Monitoring of a movable guard Multiple emergency stop monitoring 2-channel wiring Sensing mat and edges monitoring Monitoring of electro-sensitive protection equipment (ESPE) PNP/PNP Proximity sensor monitoring PNP/PNP Monitoring of electro-sensitive protection equipment (ESPE) PNP/NPN Proximity sensor monitoring PNP/NPN Monitoring of a movable guard with 2 switches and automatic start |
|
safety level |
Can reach PL e/category 4 EN/ISO 13849-1:2008
Can reach PL e/category 4 EN/ISO 13849-2:2012 Can reach SILCL 3 EN/IEC 62061:2005 Can reach SIL 3 EN/IEC 61508:2010 |
safety reliability data |
DC = 95 % EN/ISO 13849-1
PFHd = 5E-9 1/h IEC 61508-1 1 operation/hour DC-13 24 V DC 4 A PFHd = 30E-9 1/h IEC 61508-1 60 operations/hour DC-13 24 V DC 1 A MTTFd = 500 years EN/ISO 13849-1 1 operation/hour DC-13 24 V DC 4 A MTTFd = 85 years EN/ISO 13849-1 60 operations/hour DC-13 24 V DC 1 A SFF = 95 % IEC 61508-1 HFT = 1 IEC 61508-1 Type = A IEC 61508-1 |
|
---|---|---|
synchronisation time between inputs |
Unlimited
2 or 4 s depending of wiring configurable by software |
|
connections - terminals |
Captive spring terminals, removable terminal block 1 x 0.2...1 x
2.5 mm² flexible without cable end 13-14, 23-24, 33-34
Captive spring terminals, removable terminal block 1 x 0.2...1 x 2.5 mm² solid without cable end 13-14, 23-24, 33-34 Captive spring terminals, removable terminal block 1 x 0.25...1 x 2.5 mm² flexible with cable end, with bezel 13-14, 23-24, 33-34 Captive spring terminals, removable terminal block 1 x 0.25...1 x 2.5 mm² flexible with cable end, without bezel 13-14, 23-24, 33-34 Captive spring terminals, removable terminal block 2 x 0.5...2 x 1.5 mm² flexible with cable end, with double bezel 13-14, 23-24, 33-34 Captive spring terminals, removable terminal block 1 x 0.14...1 x 1.5 mm² flexible without cable end other terminals Captive spring terminals, removable terminal block 1 x 0.14...1 x 1.5 mm² solid without cable end other terminals Captive spring terminals, removable terminal block 1 x 0.25...1 x 0.5 mm² flexible with cable end, with bezel other terminals Captive spring terminals, removable terminal block 1 x 0.25...1 x 1.5 mm² flexible with cable end, without bezel other terminals |
|
output type |
Relay instantaneous opening 3 NO potential free
|
|
number of safety circuits |
3 NO (relay instantaneous opening)
|
|
maximum switching voltage |
230 V utilisation category AC-15 at 50 Hz (relay instantaneous
opening)
24 V utilisation category DC-13 (relay instantaneous opening) |
|
[Us] rated supply voltage |
24 V DC - 15...20 %
|
|
power consumption in W |
0.2 W 5 V DC
3.6 W 24 V DC |
|
input protection type |
Internal, electronic
|
|
[Uc] control circuit voltage |
24 V DC
|
|
cable distance between devices |
30 m
|
|
breaking capacity |
360 VA holding AC-15 B300 relay output
3600 VA inrush AC-15 B300 relay output |
|
breaking capacity |
4 A 24 V 50 ms DC-13 relay output
|
|
output thermal current |
6 A per relay relay output
|
|
[Ith] conventional free air thermal current |
18 A
|
|
associated fuse rating |
4 A gG or gL relay output EN/IEC 60947-5-1
6 A fast blow relay output EN/IEC 60947-5-1 |
|
minimum output current |
10 mA relay output
|
|
output voltage |
10 V relay output
|
|
response time on input open |
<= 40 ms
|
|
[Ui] rated insulation voltage |
300 V 2 IEC 60647-5-1
|
|
[Uimp] rated impulse withstand voltage |
4 kV III IEC 60647-5-1
|
|
current consumption |
100 mA 24 V DC external supply
|
|
local signalling |
8 LEDs green/red user
|
|
electrical connection |
Spring terminal
|
|
product compatibility |
Safety light curtains EN/IEC 61496-1 (type 4)
Sensing mat/edges EN 1760-1 |
|
standards |
EN/ISO 13849-1:2008
EN/ISO 13849-2:2012 EN/IEC 62061:2005 EN/IEC 61508:2010 EN/IEC 60947-5-1:2010 EN/IEC 61131-2:2007 EN/IEC 60204-1:2005 EN/IEC 60204-1:2009/A1 IEC 61010-1:2010 EN 50581:2012 |
|
product certifications |
ANSI Haz Loc Class 1 Division 2 (pending)
UL 61010-2-201 CSA 61010-2-201 (pending) TÜV CSA Haz Loc Class 1 Division 2 (pending) RCM EAC |
|
marking |
TÜV
RCM EAC REACH EFUP 10 UL CSA CE |
|
electromagnetic compatibility |
Electrostatic discharge immunity test 8 kV air discharge
conforming to EN/IEC 61000-4-2
Electrostatic discharge immunity test 6 kV contact discharge conforming to EN/IEC 61000-4-2 Susceptibility to electromagnetic fields 10 V/m 80 MHz to 1 GHz conforming to EN/IEC 61000-4-3 Susceptibility to electromagnetic fields 3 V/m 1.4 GHz...2 GHz conforming to EN/IEC 61000-4-3 Susceptibility to electromagnetic fields 1 V/m 2 GHz...3 GHz conforming to EN/IEC 61000-4-3 Magnetic field at power frequency 30 A/m 50...60 Hz conforming to EN/IEC 61000-4-8 Electrical fast transient/burst immunity test 3 kV power lines (DC) conforming to EN/IEC 61000-4-4 Electrical fast transient/burst immunity test 2 kV I/O conforming to EN/IEC 61000-4-4 1.2/50 µs shock waves immunity test 1 kV power lines (DC) conforming to EN/IEC 61000-4-5 Conducted RF disturbances 10 V 0.15...80 MHz conforming to EN/IEC 61000-4-6 Radiated emission 40 dBµV/m class A 24 V conforming to EN 55011 Radiated emission 47 dBµV/m class A 24 V conforming to EN 55011 |
|
mounting support |
Wall mount using attached fasteners
Rail top hat type TH35-7.5 IEC 60715 Rail top hat type TH35-15 IEC 60715 |
|
height |
94 mm
|
|
depth |
73 mm
|
|
width |
43.7 mm
|
|
product weight |
0.19 kg
|
standards |
EN 60204-1
EN/IEC 60947-1 EN/IEC 60947-5-1 EN/ISO 13850 EN 1088/ISO 14119 |
|
---|---|---|
resistance to electrostatic discharge |
6 kV on contact EN/IEC 61000-4-2
8 kV in air EN/IEC 61000-4-2 |
|
resistance to electromagnetic fields |
10 V/m 80 MHz...1 GHz EN/IEC 61000-4-3
3 V/m 1.4 GHz...2 GHz EN/IEC 61000-4-3 1 V/m 2 GHz...3 GHz EN/IEC 61000-4-3 |
|
resistance to magnetic fields |
30 A/m 50/60 Hz conforming to EN/IEC 61000-4-8
|
|
resistance to fast transients |
3 kV power lines (DC) EN/IEC 61000-4-4 DC
2 kV I/O lines EN/IEC 61000-4-4 |
|
surge withstand |
1 kV power lines (DC) differential mode EN/IEC 61000-4-5 DC
1 kV power lines (DC) common mode EN/IEC 61000-4-5 DC |
|
resistance to conducted disturbances |
10 V 0.15...80 MHz EN/IEC 61000-4-6
|
|
electromagnetic emission |
Radiated emissions 50 dBµV/m class A 24 V DC 30...230 Hz IEC
61131-3
Radiated emissions 57 dBµV/m class A 24 V DC 230...1000 Hz IEC 61131-3 |
|
ambient air temperature for operation |
-10...55 °C horizontal installation
|
|
ambient air temperature for storage |
-25...70 °C
|
|
relative humidity |
10...95 % without condensation in operation
10...95 % without condensation in storage |
|
IP degree of protection |
IP20 EN/IEC 60529 terminals
|
|
pollution degree |
2
|
|
operating altitude |
0...2000 m
|
|
storage altitude |
0...3000 m
|
|
vibration resistance |
+/- 3.5 mm 5...150 Hz IEC 60068-2-6
|
|
shock resistance |
15 gn 11 ms IEC 60068-2-27
|
|
mechanical robustness |
Bumps 6 ms 300 shocks 25 gn IEC 60068-2-27
|