Schneider TSXCTY2C 2 Channels Measurement and Counter Module
Optimize your automation processes with the Schneider TSXCTY2C Measurement and Counter Module, a high-performance solution designed for precision and reliability in industrial applications. This advanced module is engineered to deliver accurate measurement and counting functionalities, making it an ideal choice for various control and monitoring tasks.
Key Features:
- Dual Channel Configuration: The TSXCTY2C features two independent channels, enabling simultaneous measurement and counting of multiple signals, thereby increasing operational efficiency and data accuracy.
- High-Current Capacity: With a robust current rating of 15 mA at 24 V DC and 850 mA at 5 V DC, this module ensures reliable performance even under demanding conditions, making it suitable for a wide range of applications.
- Precision Measurement: Designed for precise data acquisition, the TSXCTY2C module supports high-resolution measurement and counting, ensuring accurate results and dependable performance.
- Versatile Applications: Ideal for use in industrial automation, process control, and machinery monitoring, this module adapts to various system requirements and operational needs.
- Robust Construction: Built with durability in mind, the TSXCTY2C is engineered to withstand harsh industrial environments, offering long-lasting reliability and reduced maintenance needs.
Technical Specifications:
- Channels: 2
- Current Consumption: 15 mA at 24 V DC; 850 mA at 5 V DC
- Measurement Range: Configurable for a broad spectrum of measurement and counting tasks
- Compatibility: Compatible with Schneider Electric’s range of automation systems, enhancing integration and system performance.
Applications:
The Schneider TSXCTY2C module is ideal for precise counting and measurement tasks in various industrial applications, including:
- Process Control: Accurate monitoring and control of manufacturing processes.
- Industrial Automation: Enhanced automation control with real-time measurement and counting.
- Machinery Monitoring: Reliable data acquisition for machinery performance assessment.
Elevate your industrial automation and control capabilities with the Schneider TSXCTY2C 2 Channels Measurement and Counter Module. Its advanced features and robust design ensure exceptional performance and reliability in even the most demanding environments.
For more information and technical support, please contact Schneider Electric’s customer service team or visit our website.
range of product |
Modicon Premium Automation platform
|
|
---|---|---|
product or component type |
Measurement and counter module
|
|
I/O modularity |
2 channels
|
|
electrical circuit type |
Auxiliary output conforming to EN/IEC 61131-2
|
counting frequency |
1000000 Hz
|
|
---|---|---|
incremental encoder frequency x1 |
500 kHz
|
|
incremental encoder frequency x 4 |
250 kHz
|
|
power dissipation in W |
7...10 W
|
|
cycle time |
1 ms
|
|
discrete input logic |
Current sink auxiliary input (preset, enable and read)
conforming to IEC 1131 Type 2
Resistive 2/3-wire proximity sensors PNP/NPN conforming to IEC 1131 Type 2 Resistive encoder input |
|
input logic |
Positive
|
|
input compatibility |
Absolute encoder SSI serial output
Incremental encoder 10...30 V totem pole Incremental encoder 5 V DC RS422 Absolute encoder parallel output ABE7CPA11 |
|
input voltage |
24 V 16 mA 2/3-wire proximity sensors PNP/NPN
24 V 8 mA auxiliary input (preset, enable and read) 5 V 18 mA encoder input |
|
input voltage limits |
<= 5.5 V encoder input
19...30 V 2/3-wire proximity sensors PNP/NPN 19...30 V auxiliary input (preset, enable and read) |
|
voltage state 1 guaranteed |
>= 11 V 2/3-wire proximity sensors PNP/NPN
>= 11 V auxiliary input (preset, enable and read) >= 2.4 V encoder input |
|
current state 1 guaranteed |
>= 6 mA 2/3-wire proximity sensors PNP/NPN
>= 6 mA auxiliary input (preset, enable and read) >= 3.6 mA encoder input |
|
voltage state 0 guaranteed |
<= 1.2 V encoder input
<= 5 V 2/3-wire proximity sensors PNP/NPN <= 5 V auxiliary input (preset, enable and read) |
|
current state 0 guaranteed |
<= 1 mA encoder input
<= 2 mA 2/3-wire proximity sensors PNP/NPN <= 2 mA auxiliary input (preset, enable and read) |
|
response time |
< 10 ms sensor voltage at return of 24 V auxiliary input
(preset, enable and read)
< 2.5 ms sensor voltage at loss of 24 V auxiliary input (preset, enable and read) |
|
input impedance |
> 270 Ohm at U = 2.4 V encoder input
1500 Ohm at Un 2/3-wire proximity sensors PNP/NPN 3400 Ohm at Un auxiliary input (preset, enable and read) 400 Ohm at Un encoder input |
|
output voltage |
24 V DC
|
|
nominal output current |
0.5 A
|
|
output voltage limits |
19...30 V
|
|
voltage drop |
< 0.5 V at state 1
|
|
output compatibility |
Positive logic DC inputs (resistance <= 15 kOhm) auxiliary
output
|
|
leakage current |
< 0.1 mA
|
|
switching time |
< 0.250 ms
|
|
switching frequency |
< 0.6/LI² Hz on inductive load
|
|
output overload protection |
Current limiter
Thermal tripping via program or automatically |
|
output short-circuit protection |
Current limiter
Thermal tripping via program or automatically |
|
output overvoltage protection |
Zener diode
|
|
reverse polarity protection |
Reverse diode on supply
|
|
checks |
Sensor power supply
|
|
current consumption |
15 mA 24 V DC
850 mA 5 V DC |
|
module format |
Standard
|
|
local signalling |
2 LEDs green axis diagnostics available (CH.)
1 LED green module operating (RUN) 1 LED red external fault (I/O) 1 LED red internal fault, module failure (ERR) |
|
electrical connection |
1 connector HE-10 20 pins
2 connectors SUB-D 15 |
|
product weight |
0.34 kg
|
protective treatment |
TC
|
|
---|---|---|
ambient air temperature for operation |
0...60 °C
|
|
ambient air temperature for storage |
-25...70 °C
|
|
relative humidity |
5...95 % without condensation
|
|
operating altitude |
<= 2000 m
|