Schneider TSXPAY262 Preventa Safety Module - Enhanced Safety Control Solution
The Schneider TSXPAY262 Preventa Safety Module stands as an exemplary solution, integrating advanced safety features into industrial systems. Engineered to operate at a robust 24 V DC, this module adheres to the highest safety standards, ensuring reliable and efficient performance across diverse industrial environments.
Key Features:
Enhanced Safety Protocols: Built to meet stringent safety requirements, this module implements state-of-the-art safety measures, offering unparalleled protection within industrial setups.
Standard Format: Designed in a standard format, ensuring seamless integration into existing systems without compromising on safety or performance.
Ultra-Low Power Consumption: Consuming less than 5 watts of power, this module not only ensures safety but also promotes energy efficiency, reducing operational costs in the long run.
Versatile Application: Suited for a wide array of industrial applications, from manufacturing plants to automated systems, ensuring safety without compromising productivity.
Technical Specifications:
Voltage Compatibility: 24 V DC, ensuring consistent and reliable power supply within industrial setups.
Power Consumption: Less than 5 watts, making it an energy-efficient addition to any system.
Compatibility: Compatible with various systems, enhancing safety across diverse industrial applications.
Robust Construction: Built with durable materials, guaranteeing longevity and reliability even in challenging working conditions.
Why Choose Schneider TSXPAY262?
With a commitment to safety, efficiency, and reliability, Schneider's TSXPAY262 Preventa Safety Module offers peace of mind in industrial operations. Its compliance with safety standards, combined with its seamless integration and minimal power consumption, makes it an optimal choice for those seeking an enhanced safety control solution.
Conclusion:
Incorporating the Schneider TSXPAY262 Preventa Safety Module into your industrial setup signifies a proactive approach to safety without compromising productivity. Its advanced safety features, compatibility, and energy efficiency make it a prime choice for businesses aiming for a safer and more efficient working environment.
Explore the Schneider TSXPAY262 today to elevate safety standards while optimizing industrial operations.
range of product |
Modicon Premium Automation platform
|
|
---|---|---|
product or component type |
Preventa safety module
|
[Us] rated supply voltage |
24 V DC
|
|
---|---|---|
supply voltage limits |
19.2...30 V
|
|
activation threshold |
< 20 V
|
|
short-circuit protection |
1 A gG external conforming to IEC 947-5-1 on power supply
4 A gG external conforming to IEC 947-5-1 on safety relay outputs |
|
isolation voltage |
4000 V III 2
|
|
discrete input number |
1 double or single contact selection input conforming to IEC
1131 Type 1
1 feedback loop input conforming to IEC 1131 Type 1 1 reset PB input conforming to IEC 1131 Type 1 1 reset PB monitoring input conforming to IEC 1131 Type 1 12 emergency stop or limit switch discrete inputs conforming to IEC 1131 Type 1 |
|
discrete input logic |
Positive
|
|
inrush current |
<= 0.5 A
|
|
isolation between input and earth |
500 Vrms 50/60 Hz for 60 s
|
|
power dissipation in W |
< 5 W
|
|
safety outputs |
2 NO safety relay AGCDO gold plated volt free output
|
|
[Ue] rated operational voltage |
17...127 V DC relay output
19...250 V AC relay output |
|
rated power in VA |
120 VA 48 V AC-15 inductive
280 VA 110 V AC-15 inductive 550 VA 220 V AC-15 inductive 60 VA 24 V AC-15 inductive |
|
rated power in W |
60 W 24 V DC-13 inductive 100 ms
|
|
[Ithe] conventional enclosed thermal current |
<= 2.5 A
|
|
minimum output current |
>= 30 mA
|
|
response time on output |
< 12 ms
|
|
isolation between output and earth |
300 V conforming to DIN VDE 0110 part 2
1500 Vrms 50/60 Hz for 60 s |
|
safety acquisition |
Monitor external power supply of the module
Read enable inputs Read feedback loop Read the safety outputs control Read status of the 24 inputs |
|
local signalling |
28 LEDs diagnostic of safety system
|
|
electrical connection |
1 connector removable screw terminal block 6 pins for connecting
the safety output
1 connector SUB-D 44 pins for connecting the safety system input |
|
cable cross section |
1.5 mm² with cable end safety output circuit
0.2...2.5 mm² without cable end safety output circuit |
|
current consumption |
< 150 mA 5 V DC
<= 200 mA 24 V DC |
|
module format |
Standard
|
|
product weight |
0.43 kg
|
ambient air temperature for operation |
0...40 °C without fan
0...60 °C with fan module |
|
---|---|---|
ambient air temperature for storage |
-25...70 °C
|
|
IP degree of protection |
IP20 conforming to IEC 60529
|
|
standards |
CSA C22.2 specific requirements (PLC)
EN 954 machine safety parts of control systems EN/IEC 60204-1 machine electrical equipment EN/IEC 61131-2 specific requirements (PLC) EN/ISO 12100 machine electrical equipment ISO 13850 emergency stop equipment UL 508 specific requirements (PLC) ISO 13849-1 category 4 machine safety parts of control systems IEC 61508 SIL 3 machine safety parts of control systems |
|
product certifications |
BG
CSA UL |