Schneider TSXPAY282C Preventa Safety Module - 24 V DC - Standard Format - < 5W
Overview
The Schneider TSXPAY282C Preventa Safety Module represents the pinnacle of industrial safety technology, designed to enhance operational safety and efficiency in automated environments. This state-of-the-art safety module offers unparalleled reliability and performance, making it an essential component for safeguarding machinery and personnel in industrial settings.
Key Features
- Voltage Rating: 24 V DC
- Power Consumption: Less than 5W
- Format: Standard module design for ease of integration
- Compliance: Adheres to stringent safety standards, ensuring reliable protection and performance
Technical Specifications
- Input Type: Digital inputs for versatile integration with various safety devices
- Output Type: Configurable outputs to interface with safety relays and other control systems
- Safety Category: Meets high safety category requirements (Cat. 4, PLe) in accordance with ISO 13849-1 standards
- Response Time: Quick response time for effective emergency stops and fault detection
- Mounting: Designed for standard DIN rail mounting, simplifying installation and maintenance
Applications
Ideal for use in a wide range of industrial applications, the TSXPAY282C is suitable for:
- Machine Safety Systems: Protects operators and machinery by ensuring proper safety measures are in place
- Automated Production Lines: Integrates seamlessly with automated systems to maintain safety without compromising productivity
- Robotic Workcells: Provides reliable safety monitoring and control for robotic applications
Benefits
- Enhanced Safety: Provides robust protection for personnel and equipment by ensuring compliance with the latest safety regulations
- Efficient Integration: Standard format and DIN rail compatibility facilitate quick and straightforward installation
- Low Power Consumption: Designed to operate efficiently with minimal energy consumption, reducing operational costs
- Reliability: Built to withstand demanding industrial environments and maintain high performance over time
Compliance and Certification
The Schneider TSXPAY282C Preventa Safety Module complies with international safety standards, including ISO 13849-1 and IEC 61508, ensuring it meets rigorous safety and reliability requirements. Its adherence to these standards guarantees that it will perform consistently and effectively in safeguarding critical operations.
Conclusion
The Schneider TSXPAY282C Preventa Safety Module is a top-tier solution for industrial safety, offering advanced features and exceptional reliability. Its standard format, low power consumption, and compliance with high safety standards make it an ideal choice for enhancing safety in automated systems and industrial machinery.
range of product |
Modicon Premium Automation platform
|
|
---|---|---|
product or component type |
Preventa safety module
|
[Us] rated supply voltage |
24 V DC
|
|
---|---|---|
supply voltage limits |
19.2...30 V
|
|
activation threshold |
< 20 V
|
|
short-circuit protection |
1 A gG external conforming to IEC 947-5-1 for F1 on power supply
4 A gG external conforming to IEC 947-5-1 for F2 on safety relay outputs |
|
isolation voltage |
4000 V III 2
|
|
discrete input number |
1 double or single contact selection input conforming to IEC
1131 Type 1
1 feedback loop input conforming to IEC 1131 Type 1 1 reset PB input conforming to IEC 1131 Type 1 1 reset PB monitoring input conforming to IEC 1131 Type 1 12 emergency stop or limit switch discrete inputs conforming to IEC 1131 Type 1 |
|
discrete input logic |
Positive
|
|
inrush current |
<= 0.5 A
|
|
isolation between input and earth |
500 Vrms 50/60 Hz for 60 s
|
|
power dissipation in W |
< 5 W
|
|
safety outputs |
4 NO safety relay AGCDO gold plated volt free output
|
|
[Ue] rated operational voltage |
17...127 V DC relay output
19...250 V AC relay output |
|
rated power in VA |
120 VA 48 V AC-15 inductive
280 VA 110 V AC-15 inductive 550 VA 220 V AC-15 inductive 60 VA 24 V AC-15 inductive |
|
rated power in W |
60 W 24 V DC-13 inductive 100 ms
|
|
[Ithe] conventional enclosed thermal current |
<= 2.5 A
|
|
minimum output current |
>= 30 mA
|
|
response time on output |
< 12 ms
|
|
isolation between output and earth |
300 V conforming to DIN VDE 0110 part 2
1500 Vrms 50/60 Hz for 60 s |
|
safety acquisition |
Monitor external power supply of the module
Read enable inputs Read feedback loop Read the safety outputs control Read status of the 24 inputs |
|
local signalling |
28 LEDs diagnostic of safety system
|
|
electrical connection |
1 connector removable screw terminal block 6 pins
1 connector SUB-D 44 pins for connecting the safety system |
|
cable cross section |
1.5 mm² with cable end safety output circuit
0.2...2.5 mm² without cable end safety output circuit |
|
current consumption |
< 150 mA 5 V DC
<= 200 mA 24 V DC |
|
module format |
Standard
|
|
product weight |
0.49 kg
|
ambient air temperature for operation |
0...40 °C without fan
0...60 °C with fan module |
|
---|---|---|
ambient air temperature for storage |
-25...70 °C
|
|
IP degree of protection |
IP20 conforming to IEC 60529
|
|
standards |
CSA C22.2 specific requirements (PLC)
EN 954 machine safety parts of control systems EN/IEC 60204-1 machine electrical equipment EN/IEC 61131-2 specific requirements (PLC) EN/ISO 12100 machine electrical equipment ISO 13850 emergency stop equipment UL 508 specific requirements (PLC) ISO 13849-1 category 4 machine safety parts of control systems IEC 61508 SIL 3 machine safety parts of control systems |
|
product certifications |
BG
CSA UL |
|
protective treatment |
Conformal coating Humiseal 1A33
|