• Schneider VW3A4703 EMC Radio Interference Input Filter - 35A for Variable Speed Drives

Schneider VW3A4703 EMC Radio Interference Input Filter - 35A for Variable Speed Drives

Overview:

The Schneider VW3A4703 EMC Radio Interference Input Filter is engineered to provide superior electromagnetic compatibility (EMC) for variable speed drives. Designed for applications requiring robust interference suppression, this filter ensures the reliable operation of your equipment by minimizing radio frequency interference (RFI) and electromagnetic interference (EMI).

Key Features:

  • Current Rating: 35A – Capable of handling significant current loads, making it suitable for high-demand industrial applications.
  • Electromagnetic Interference Reduction: Effectively reduces RFI and EMI, enhancing the performance and stability of your variable speed drives by preventing interference with other electronic devices.
  • Enhanced Reliability: Constructed with high-quality materials and rigorous manufacturing standards to ensure long-term reliability and durability in demanding environments.
  • Compliance: Meets industry standards for EMC performance, ensuring your equipment complies with regulatory requirements for electromagnetic compatibility.
  • Compact Design: Engineered for easy installation with minimal impact on system space, this filter integrates seamlessly into your existing setup.

Applications:

The Schneider VW3A4703 EMC Radio Interference Input Filter is ideal for use in a variety of industrial applications where electromagnetic interference could impact system performance. It is particularly well-suited for variable speed drives in sectors such as manufacturing, automation, and industrial processing.

Technical Specifications:

  • Filter Type: EMC Radio Interference Input Filter
  • Rated Current: 35A
  • Application: Variable Speed Drives
  • Mounting: Designed for easy integration into existing systems
  • Compliance: Adheres to EMC standards for effective interference suppression

Benefits:

  • Improved Equipment Performance: By minimizing electromagnetic interference, the filter helps maintain the optimal performance of your variable speed drives.
  • Reduced Downtime: Enhanced reliability leads to fewer disruptions and maintenance needs, reducing operational downtime.
  • Regulatory Compliance: Ensures your equipment meets necessary EMC regulations, avoiding potential fines and operational issues.

Why Choose Schneider VW3A4703?

With the Schneider VW3A4703 EMC Radio Interference Input Filter, you gain a dependable solution for managing electromagnetic interference in your variable speed drive systems. Schneider Electric’s commitment to quality and innovation ensures that this filter will provide the performance and reliability you need to maintain efficient and compliant operations.

Optimize Your Industrial Systems with Schneider VW3A4703 – The Ultimate Choice for EMC Radio Interference Filtering.

Main
range of product
Altivar
product or component type
EMC input filter
range compatibility
Altivar Process ATV600
Altivar Process ATV900
product compatibility
ATV630 wall mount, at 7.5 kW, 380...480 V
ATV630 wall mount, at 11 kW, 380...480 V
ATV630 wall mount, at 15 kW, 380...480 V
ATV630 wall mount, at 4 kW, 200...240 V
ATV630 wall mount, at 5.5 kW, 200...240 V
ATV630 wall mount, at 7.5 kW, 200...240 V
ATV650 wall mount, at 7.5 kW, 380...480 V
ATV650 wall mount, at 11 kW, 380...480 V
ATV650 wall mount, at 15 kW, 380...480 V
ATV930 wall mount, at 7.5 kW, 380...480 V
ATV930 wall mount, at 11 kW, 380...480 V
ATV930 wall mount, at 15 kW, 380...480 V
ATV930 wall mount, at 4 kW, 200...240 V
ATV930 wall mount, at 5.5 kW, 200...240 V
ATV930 wall mount, at 7.5 kW, 200...240 V
ATV950 wall mount, at 7.5 kW, 380...480 V
ATV950 wall mount, at 11 kW, 380...480 V
ATV950 wall mount, at 15 kW, 380...480 V
product specific application
Radio interference input filter
[In] rated current
35 A
thermal losses
4.8 W
network number of phases
Three phase
Complementary
electrical connection
Terminal 6 mm² AWG 8
motor cable length
<= 150 m shielded motor cable 4 kHz conforming to EN/IEC 61800-3 category C2, 380...480 V
<= 300 m shielded motor cable 4 kHz conforming to EN/IEC 61800-3 category C3, 380...480 V
<= 150 m shielded motor cable 4 kHz conforming to EN/IEC 61800-3 category C2, 200...240 V
<= 300 m shielded motor cable 4 kHz conforming to EN/IEC 61800-3 category C3, 200...240 V
<= 50 m shielded motor cable 4 kHz conforming to EN/IEC 61800-3 category C1, 200...240 V
<= 50 m shielded motor cable 4 kHz conforming to EN/IEC 61800-3 category C1, 380...480 V
maximum earth leakage current
7.6 mA at 400 V 50 Hz TN
7.6 mA at 400 V 50 Hz TT
power supply voltage
380...480 V
200...240 V
tolerance
10 %
mechanical robustness
Shocks conforming to IEC 60721-3-3 class 3M4
Vibrations conforming to IEC 60721-3-3 class 3M4
width
80 mm
height
302 mm
depth
155 mm
product weight
4.1 kg

Environment
IP degree of protection
IP20 mounting side by side
IP21 with kit VW3A47903
relative humidity
5...95 % without condensation conforming to IEC 61800-5-1
ambient air temperature for operation
50...60 °C with current derating 1.5 % per °C
-10...50 °C without current derating
ambient air temperature for storage
-40...70 °C
operating altitude
0...1000 m without current derating
1000...4000 m with current derating 1 % per 100 m
standards
EN/IEC 61800-3

Schneider VW3A4703 EMC Radio Interference Input Filter - 35A for Variable Speed Drives

  • Brand: Schneider
  • Product Code: VW3A4703
  • Availability: 1000

Tags: Schneider VW3A4703, EMC Input Filter, Radio Interference Filter, 35A Filter, Variable Speed Drive, Electromagnetic Compatibility, RFI Filter, EMI Filter, Industrial Filter, Schneider Electric