Schneider VW3A5209 Sinus Filter - 400 A for Altivar Variable Speed Drives
Product Overview:
The Schneider VW3A5209 Sinus Filter is engineered to enhance the performance and longevity of your Altivar variable speed drives by mitigating the effects of electromagnetic interference (EMI) and reducing harmonic distortion. Designed for high-current applications, this 400 A sinus filter ensures optimal operation and reliability in demanding industrial environments.
Key Features:
Advanced EMI Suppression: The VW3A5209 is specifically designed to attenuate high-frequency noise and reduce electromagnetic interference, protecting sensitive equipment and ensuring compliance with EMC regulations.
Harmonic Distortion Reduction: This filter minimizes harmonic distortion in the power supply, leading to improved power quality and enhanced efficiency of your variable speed drive system.
Robust Construction: Built to withstand the rigors of industrial use, the VW3A5209 features a durable design that ensures long-term reliability and consistent performance in harsh operating conditions.
Compatibility: Perfectly suited for use with Schneider Electric’s Altivar variable speed drives, this filter seamlessly integrates into your existing setup, offering a hassle-free installation process.
High Current Capacity: With a rated current of 400 A, the VW3A5209 is capable of handling substantial power loads, making it ideal for high-demand applications and ensuring stable performance even under heavy operating conditions.
Technical Specifications:
- Rated Current: 400 A
- Type: Sinus Filter
- Application: For use with Altivar Variable Speed Drives
- Features: EMI suppression, harmonic distortion reduction
- Construction: Industrial-grade, robust design
Benefits:
Enhanced Equipment Protection: By reducing EMI and harmonic distortion, the VW3A5209 helps safeguard your machinery and extend its operational lifespan.
Improved System Efficiency: By maintaining a cleaner power supply, this filter enhances the overall efficiency and performance of your variable speed drive system.
Regulatory Compliance: Meets EMC requirements, helping you maintain compliance with industry standards and regulations.
Applications:
Ideal for use in a wide range of industrial applications, including manufacturing, automation, and process control systems where high current and reliable performance are critical.
Why Choose Schneider VW3A5209?
Opt for the Schneider VW3A5209 Sinus Filter to ensure superior performance, reduced downtime, and increased longevity for your Altivar variable speed drives. Its advanced design and high-current capacity make it a reliable choice for demanding industrial environments.
SEO Keywords:
- Schneider VW3A5209 Sinus Filter
- 400 A Sinus Filter
- Altivar Variable Speed Drive Filter
- EMI Suppression Filter
- Harmonic Distortion Reduction
- Industrial Sinus Filter
- Schneider Electric Filters
product or component type |
Sinus filter
|
|
---|---|---|
range compatibility |
Altivar 61
Altivar 71 Altivar 61Q Altivar 71Q Altivar Process ATV600 Altivar Process ATV900 |
|
product specific application |
Output filter
|
|
[In] rated current |
600 A
|
|
thermal losses |
2370 W at 100 Hz
|
|
product compatibility |
ATV61HC31N4
ATV61QC25N4 ATV61QC31N4 ATV71HC25N4 ATV71HC28N4 ATV71QC25N4 ATV61QC40N4 ATV71QC31N4 ATV71QC40N4 ATV930 variable speed drive wall mount - 250 kW, 380...480 V ATV930 variable speed drive wall mount - 315 kW, 380...480 V ATV61HC40N4 ATV71HC31N4 ATV71HC40N4 ATV61HC25N4 |
|
switching frequency |
4...8 kHz
|
|
output frequency |
<= 100 Hz
|
|
maximum permissible voltage |
500 V AC
|
electrical connection |
Bare wires, Ø = 14 mm
|
|
---|---|---|
voltage drop at rated load |
< 10 %
|
|
max current |
1.5 x nominal current for 60 s
|
|
product weight |
260 kg
|
IP degree of protection |
IP00
|
|
---|---|---|
environmental characteristic |
3B1 conforming to IEC 721-3-3
3C2 conforming to IEC 721-3-3 3S1 conforming to IEC 721-3-3 |
|
pollution degree |
2 conforming to EN 50178
|
|
vibration resistance |
1 gn (f = 13...200 Hz) conforming to IEC 60068-2
1.5 mm peak to peak (f = 3...13 Hz) conforming to IEC 60068-2 |
|
shock resistance |
15 gn for 11 ms conforming to IEC 60068-2-27
|
|
relative humidity |
0...95 %
|
|
ambient air temperature for operation |
> 40...50 °C with current derating 1.5 % per °C
-10...40 °C without current derating |
|
ambient air temperature for storage |
-40...65 °C
|
|
operating altitude |
<= 1000 m without current derating
1000...3000 m with current derating 1 % per 100 m |